Feasibility study of computational occupational dosimetry: evaluating a proof-of-concept in an endovascular and interventional cardiology setting
Open Access
- 5 October 2022
- journal article
- research article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 42 (4) , 041501
Abstract
Individual monitoring of radiation workers is essential to ensure compliance with legal dose limits and to ensure that doses are As Low As Reasonably Achievable. However, large uncertainties still exist in personal dosimetry and there are issues with compliance and incorrect wearing of dosimeters. The objective of the PODIUM (Personal Online Dosimetry Using Computational Methods) project was to improve personal dosimetry by an innovative approach: the development of an online dosimetry application based on computer simulations without the use of physical dosimeters. Occupational doses were calculated based on the use of camera tracking devices, flexible individualised phantoms and data from the radiation source. When combined with fast Monte Carlo simulation codes, the aim was to perform personal dosimetry in real-time. A key component of the PODIUM project was to assess and validate the methodology in interventional radiology workplaces where improvements in dosimetry are needed. This paper describes the feasibility of implementing the PODIUM approach in a clinical setting. Validation was carried out using dosimeters worn by Vascular Surgeons and Interventional Cardiologists during patient procedures at a hospital in Ireland. Our preliminary results from this feasibility study show acceptable differences of the order of 40% between calculated and measured staff doses, in terms of the personal dose equivalent quantity Hp(10), however there is a greater deviation for more complex cases and improvements are needed. The challenges of using the system in busy interventional rooms have informed the future needs and applicability of PODIUM. The availability of an online personal dosimetry application has the potential to overcome problems that arise from the use of current dosimeters. In addition, it should increase awareness of radiation protection among staff. Some limitations remain and a second phase of development would be required to bring the PODIUM method into operation in a hospital setting. However, an early prototype system has been tested in a clinical setting and the results from this two-year proof-of-concept PODIUM project are very promising for future development.Keywords
Funding Information
- CONCERT-European Joint Programme for the Integration of Radiation Protection Research (2014–2018)
This publication has 24 references indexed in Scilit:
- A summary of recommendations for occupational radiation protection in interventional cardiologyCatheterization and Cardiovascular Interventions, 2012
- Personal dosimetry for interventional operators: when and how should monitoring be done?British Journal of Radiology, 2011
- Radiological Protection in Fluoroscopically Guided Procedures Performed Outside the Imaging DepartmentAnnals of the ICRP, 2010
- Risk for radiation‐induced cataract for staff in interventional cardiology: Is there reason for concern?Catheterization and Cardiovascular Interventions, 2010
- Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional RadiologyCardioVascular and Interventional Radiology, 2009
- Monte Carlo simulations of occupational radiation doses in interventional radiologyBritish Journal of Radiology, 2007
- Preface, Executive Summary and GlossaryAnnals of the ICRP, 2007
- Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizationsBritish Journal of Radiology, 2003
- Abstract: Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85Annals of the ICRP, 2000
- General principles for the radiation protection of workersAnnals of the ICRP, 1997