UOU. O'Connor

U. O'Connor

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


U. O'Connor has a total of 79 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Feasibility study of computational occupational dosimetry: evaluating a proof-of-concept in an endovascular and interventional cardiology setting

    by U O’cOnnor, C Walsh, D Gorman, G O’rEilly, Z Martin, P Madhavan, R T Murphy, R Szirt, A Almén, M Andersson, et al.

    Individual monitoring of radiation workers is essential to ensure compliance with legal dose limits and to ensure that doses are As Low As Reasonably Achievable. However, large uncertainties still exist in personal dosimetry and there are issues with compliance and incorrect wearing of dosimeters. The objective of the PODIUM (Personal Online Dosimetry Using Computational Methods) project was to improve personal dosimetry by an innovative approach: the development of an online dosimetry application based on computer simulations without the use of physical dosimeters. Occupational doses were calculated based on the use of camera tracking devices, flexible individualised phantoms and data from the radiation source. When combined with fast Monte Carlo simulation codes, the aim was to perform personal dosimetry in real-time. A key component of the PODIUM project was to assess and validate the methodology in interventional radiology workplaces where improvements in dosimetry are needed. This paper describes the feasibility of implementing the PODIUM approach in a clinical setting. Validation was carried out using dosimeters worn by Vascular Surgeons and Interventional Cardiologists during patient procedures at a hospital in Ireland. Our preliminary results from this feasibility study show acceptable differences of the order of 40% between calculated and measured staff doses, in terms of the personal dose equivalent quantity Hp(10), however there is a greater deviation for more complex cases and improvements are needed. The challenges of using the system in busy interventional rooms have informed the future needs and applicability of PODIUM. The availability of an online personal dosimetry application has the potential to overcome problems that arise from the use of current dosimeters. In addition, it should increase awareness of radiation protection among staff. Some limitations remain and a second phase of development would be required to bring the PODIUM method into operation in a hospital setting. However, an early prototype system has been tested in a clinical setting and the results from this two-year proof-of-concept PODIUM project are very promising for future development.


  • Personal dosimetry for positron emitters, and occupational exposures from clinical use of gallium-68

    by J Eakins, L Hager, U O’cOnnor, J Cooke, G O’rEilly, C Walsh, T Willson

    The current status and issues regarding positron dosimetry in nuclear medicine are summarized. The suitability of the United Kingdom Health Security Agency extremity and eye beta-gamma personal thermoluminescence dosemeters are then considered. Monte Carlo modelling is performed to determine their responses and derive sets of calibration factors, along with H p(0.07) and H p(3) conversion coefficients, for carbon-11, nitrogen-13, oxygen-15, fluorine-18 and gallium-68 sources, which are commonly used in positron emission tomography (PET) computed tomography; data for these isotopes is assumed extrapolatable to other positron sources. It is found that the dosemeters are adequate for assessing exposures to PET radionuclides, even if their routine calibrations to caesium-137 were maintained. An idealized set of measurements representing gallium-68 exposure scenarios is then described, including reproducible mock-ups of individuals manipulating vials and syringes. Finally, a short case-study is presented that explores occupational doses during routine clinical use of gallium-68. The extremity dosemeter results demonstrated significant variations dependent upon the exposure conditions, with some seen to be comparatively large; whole-body and eye dose rates per activity were found to be lower. The importance of routine dose monitoring of workers is emphasized, with the need for a longer-termed follow-up study demonstrated.


  • Open Access

    What Is Worth Knowing in Interventional Practices about Medical Staff Radiation Exposure Monitoring: A Review of Recent Outcomes of EURADOS Working Group 12

    by Paolo Ferrari, Mercè Ginjaume, Oliver Hupe, Una O’connor, Filip Vanhavere, Elena Bakhanova, Frank Becker, Lorenzo Campani, Eleftheria Carinou, Isabelle Clairand, et al.

    EURADOS (European Radiation Dosimetry Group) Working Group 12 (WG12) SG1 activities are aimed at occupational radiation protection and individual monitoring in X-ray and nuclear medicine practices. In recent years, many studies have been carried out in these fields, especially for interventional radiology and cardiology workplaces (IC/IR). The complexity of the exposure conditions of the medical staff during interventional practices makes the radiation protection and monitoring of the exposed workers a challenging task. The scope of the present work is to review some of the main results obtained within WG12 activities about scattered field characterization and personal dosimetry that could be very useful in increasing the quality of radiation protection of the personnel, safety, and awareness of radiation risk. Two papers on Monte Carlo modelling of interventional theater and three papers on active personal dosimeters (APDs) for personnel monitoring were considered in the review. More specifically, Monte Carlo simulation was used as the main tool to characterize the levels of exposure of the medical staff, allowing to determine how beam energy and direction can have an impact on the doses received by the operators. Indeed, the simulations provided information about the exposure of the operator’s head, and the study concluded with the determination of an eye-lens protection factor when protection goggles and a ceiling shielding are used. Moreover, the review included the results of studies on active personal dosimeters, their use in IC/IR workplaces, and how they respond to calibration fields, with X-ray standard and pulsed beams. It was shown that APDs are insensitive to backscatter radiation, but some of them could not respond correctly to the very intense pulsed fields (as those next to the patient in interventional practices). The measurements during interventional procedures showed the potential capability of the employment of APDs in hospitals.


  • Open Access

    Recommendations for the use of active personal dosemeters (APDs) in interventional workplaces in hospitals

    by U. O'COnnor, E. Carinou, I. Clairand, O. Ciraj-Bjelac, F. De Monte, J. Domienik-Andrzejewska, P. Ferrari, M. Ginjaume, H. Hršak, O. Hupe, et al.


  • Occupational radiation dose to eyes from interventional radiology procedures in light of the new eye lens dose limit from the International Commission on Radiological Protection

    by U O'Connor, C Walsh, A Gallagher, A Dowling, M Guiney, J M Ryan, N McEniff, G O'Reilly

    In 2011, the International Commission on Radiological Protection (ICRP) recommended a substantial reduction in the equivalent dose limit for the lens of the eye, in line with a reduced threshold of absorbed dose for radiation-induced cataracts. This is of particular relevance in interventional radiology (IR) where it is well established that staff doses can be significant, however, there is a lack of data on IR eye doses in terms of Hp(3). Hp(3) is the personal dose equivalent at a depth of 3 mm in soft tissue and is used for measuring lens dose. We aimed to obtain a reliable estimate of eye dose to IR operators. Lens doses were measured for four interventional radiologists over a 3-month period using dosemeters specifically designed to measure Hp(3). Based on their typical workloads, two of the four interventional radiologists would exceed the new ICRP dose limit with annual estimated doses of 31 and 45 mSv to their left eye. These results are for an "unprotected" eye, and for IR staff who routinely wear lead glasses, the dose beneath the glasses is likely to be significantly lower. Staff eye dose normalized to patient kerma-area product and eye dose per procedure have been included in the analysis. Eye doses to IR operators have been established using a dedicated Hp(3) dosemeter. Estimated annual doses have the potential to exceed the new ICRP limit. We have estimated lens dose to interventional radiologists in terms of Hp(3) for the first time in an Irish hospital setting.


  • Open Access

    Occupational radiation dose to eyes from endoscopic retrograde cholangiopancreatography procedures in light of the revised eye lens dose limit from the International Commission on Radiological Protection

    by U O’cOnnor, A Gallagher, L Malone, G O’rEilly

    Objective:Endoscopic retrograde cholangiopancreatography (ERCP) is a common procedure that combines the use of X-ray fluoroscopy and endoscopy for examination of the bile duct. Published data on ERCP doses are limited, including staff eye dose from ERCP. Occupational eye doses are of particular interest now as the International Commission on Radiological Protection (ICRP) has recommended a reduction in the dose limit to the lens of the eye. The aim of this study was to measure occupational eye doses obtained from ERCP procedures.Methods:A new eye lens dosemeter (EYE-D™, Radcard, Krakow, Poland) was used to measure the ERCP eye dose, Hp(3), at two endoscopy departments in Ireland. A review of radiation protection practice at the two facilities was also carried out.Results:The mean equivalent dose to the lens of the eye of a gastroenterologist is 0.01 mSv per ERCP procedure with an undercouch X-ray tube and 0.09 mSv per ERCP procedure with an overcouch X-ray tube. Staff eye dose normalised to patient kerma ...


  • Practical application of suspension criteria scenarios in general radiography, computed radiography,digital radiography and fluoroscopy

    by U. O'Connor, A. Gallagher, G. O'Reilly, A. Dowling, J. F. Malone

    Radiological equipment must be assessed against criteria for acceptability to ensure that it meets the minimum standards for patient safety. This assessment is typically led by a medical physicist with input from radiology staff and the equipment supplier. Equipment that does not meet the criteria requires action and may be suspended from clinical use. European Commission report RP 91 will be revised and replaced as RP 162. It has been drawn up to aid medical physicists with the assessment process and provide guidance on suspension levels. This paper details several cases where the criteria in the proposed RP 162 were applied in general radiography, computed radiography, digital radiography and fluoroscopy. The factors considered by the medical physicist and the outcome of each case are presented. The proposed RP 162 report improves on its predecessor and provides a robust set of criteria for ensuring that patient safety within the EU medical exposures framework is optimised.

  • Acceptance testing of fluoroscopy systems used for interventional purposes

    by U. O'Connor, A. Dowling, A. Gallagher, D. Gorman, C. Walsh, A. Larkin, L. Gray, M. Devine, J. Malone

    This study presents the results of acceptance testing on 18 interventional fluoroscopy systems in Ireland. Acceptance testing and routine quality assurance (QA) of X-ray systems are the requirements of the EU Medical Exposures Directive (MED) and these requirements were subsequently implemented into Irish legislation. The MED states that special consideration should be given to the QA and dose assessment of high dose procedures such as interventional fluoroscopy. Owing to the advances in fluoroscopy technology, it has been found that comprehensive testing of interventional systems proves challenging in a busy hospital environment. A number of recurrent problems have been identified and are presented.


  • Development of training syllabi for radiation protection and quality assurance of dual-energy X-ray absorptiometry (DXA) systems

    by U. O'Connor, A. Dowling, A A Larkin, N. Sheahan, L. Gray, A. Gallagher, G. O'Reilly, A. Kosunen, U. Zdesar, J. F. Malone

    The use of dual-energy X-ray absorptiometry (DXA) scanners for measuring bone mineral density (BMD) is on the increase. A single DXA scan is a relatively low-dose diagnostic X-ray examination; however, radiation protection (RP) issues should not be trivialised. One objective of the EU 6th Framework SENTINEL co-ordination action was to develop training syllabi in RP and quality assurance (QA) for BMD, and this study presents the results. An EU-wide survey was carried out which confirmed that there was a need for an accredited DXA RP training course in many EU states. There is also limited published guidance on acceptance testing/QA for DXA. Two training syllabi were developed: one on RP and one on QA of DXA systems. A training course was delivered in Ireland in 2006 by the Medical Physics & Bioengineering Department of St James's Hospital, Dublin. Following the training course, a PC-based training CD was developed and will be made available. A harmonised approach to training will promote consistent approaches to radiation safety across the EU.


  • Quality control measurements for fluoroscopy systems in eight countries participating in the SENTINEL EU coordination action

    by J. Zoetelief, F. W. Schultz, S. Kottou, L. Gray, U. O'Connor, D. Salat, K. Kepler, P. Kaplanis, J. Jankowski, A. Schreiner, et al.

    Quality control (QC) is becoming increasingly important in relation to the introduction of digital medical imaging systems using X rays. It was, therefore, decided to organise and perform a trial on image quality and physical measurements. The SENTINEL toolkit for QC measurements of fluoroscopy systems containing equipment and instructions for their use in the assessment of dose and image quality circulated among participants in the trial. The participants reported on their results. In the present contribution, the impact of the trial on the selected protocols is presented. The Medical Physics and Bioengineering protocol appeared to be useful for QC, and also for digital systems. The protocol needs an additional section, or an addition to each section, to state compliance with the requirements. The circular cross-sections of the Leeds test objects need adaptation for rectangular flat panel detector (FPD) systems. Only one participant was able to perform the monitor test using MoniQA. This is due to the fact that assistance is required from the suppliers of the X-ray systems. This problem needs to be solved to apply MoniQA in practice.