A higher reliability with a computed tomography scan-based three dimensional technique than with a two dimensional measurement for lower limb discrepancy in total hip arthroplasty planning
Authors:
- 4 August 2021
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 45 (12) , 3129-3137
Abstract
Purpose The goal was to compare the reliability of a novel 3D method with the standard 2D technique for lower limb discrepancy (LLD) measurement during pre-operative THA planning. Methods This prospective study included 100 consecutive patients who underwent THA using 3D planning based on a low-dose CT scan. The LLD was subdivided into three parameters: the intra-articular LLD (IA-LLD), the segmental extra-articular LLD (EA-LLD), and the total LLD (T-LLD). The LLD was assessed with a standard 2D technique on CT scanograms and also with a 3D method. A pelvic reference line (PBL) was determined as the 3D line joining the deepest part of the two great sciatic notches. The IA length was measured from the lesser trochanters (MLT) to the PBL. The EA length was measured from the MLT to the ankle center, and the total length was measured from the ankle center to the PBL. The intra- and inter-observer reliability of the measurements was assessed with the intra-class correlation coefficient (ICC). Results The intra-observer ICC was higher with the 3D technique for IA-LLD (0.96–0.97 vs. 0.79–0.84), EA-LLD (0.96 vs. 0.78–0.92), and T-LLD (0.99 vs. 0.90–0.97). Inter-observer ICC was also higher with the 3D technique for IA-LLD (0.90–0.94 vs. 0.70–0.84) and EA-LLD (0.93–0.96 vs. 0.80–0.82), but not for T-LLD (0.91–0.94 vs. 0.91–0.94). Conclusion The presented 3D method has a higher reliability than 2D assessment of LLD during pre-operative THA planning. This article presents the first discussion of measuring LLD from 3D models. As 3D reconstruction becomes both more feasible and less-invasive, this study has interest to the orthopaedic surgeon.Keywords
This publication has 17 references indexed in Scilit:
- The Assessment of Limb Length Discrepancy Before Total Hip ArthroplastyThe Journal of Arthroplasty, 2016
- Low Dose Computed Tomography for 3D Planning of Total Hip ArthroplastyJournal of Computer Assisted Tomography, 2015
- Assessment of Lower Limb Length and Alignment by Biplanar Linear Radiography: Comparison With Supine CT and Upright Full-Length RadiographyAmerican Journal of Roentgenology, 2014
- Weight-Bearing CT Imaging of the Lower ExtremityAmerican Journal of Roentgenology, 2013
- Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neckThe Journal of Bone and Joint Surgery. British volume, 2009
- Methods for Assessing Leg Length DiscrepancyClinical Orthopaedics and Related Research, 2008
- Prevalence and functional impact of patient-perceived leg length discrepancy after hip replacementInternational Orthopaedics, 2008
- Effect of Anesthesia Type on Limb Length Discrepancy After Total Hip ArthroplastyThe Journal of Arthroplasty, 2008
- AAPM/RSNA Physics Tutorial for Residents: Topics in CTRadioGraphics, 2002