Corrosion failure of post-tensioning tendons in alkaline and chloride-free segregated grout: a case study
- 12 February 2014
- journal article
- research article
- Published by Taylor & Francis in Structure and Infrastructure Engineering
- Vol. 11 (3) , 402-411
Abstract
This paper describes a case study of corrosion of post-tensioning strands in segregated grout that led to failure of one of the external tendons of a bridge after less than 2 years from the construction. Unexpectedly, severe corrosion attacks took place in areas where the ducts were filled by the injection grout, but segregation of the grout led to the presence of an unhardened whitish paste. A detailed inspection of the failed tendon, as well as other tendons removed afterwards, showed that corrosion occurred mainly in the inclined parts of the external post-tensioning tendons, in the presence of whitish grout. Analysis on samples of segregated grout showed that it was highly alkaline and had a high content of sulphate ions, but was free of chloride ions, excluding thus the normal causes of corrosion of steel in cement-based materials. Microstructural analysis of failed wires also excluded the failure for hydrogen embrittlement.Keywords
This publication has 5 references indexed in Scilit:
- Corrosion of Steel in Concrete2013
- High pH Corrosion of Prestressing Steel in Segregated Grout2011
- Steel corrosion and service life of reinforced concrete structuresStructure and Infrastructure Engineering, 2008
- Polyethylene Duct Cracking on Posttensioning Tendons in Florida Segmented BridgesJournal of Materials in Civil Engineering, 2006
- Corrosion induced failure mechanisms of prestressing steelMaterials and Corrosion, 2002