Luca Bertolini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Luca Bertolini has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Elena Redaelli
Politecnico di Milano
27 shared publications - Federica Lollini
Politecnico di Milano
19 shared publications Maddalena Carsana
9 shared publications- Tommaso Pastore
University of Bergamo, BERGAMO, Italy
8 shared publications - Maddalena Carsana
Politecnico di Milano
7 shared publications M. Gastaldi
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta” Politecnico di Milano via Mancinelli, 7 I‐20131 Milano Italy
5 shared publications
Latest Publications
- Open Access
- 1 December 2017
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 7, 36-44
A study on the cement-based decorative materials in the San Fedele Church in Milan
- 1 December 2017
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 7, 36-44
Open AccessA study on the cement-based decorative materials in the San Fedele Church in Milan
- 1 June 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 28 (6)
Characterization of Segregated Grout Promoting Corrosion of Posttensioning Tendons
Segregation of grout applied for the protection of posttensioning steel may cause corrosion of steel wires, leading to serious hazards to the safety of posttensioned structures. Several cases of failure of external tendons of bridges have been documented arising from heavily corrosion attacks initiated and propagated in the presence of an unhardened (soft) whitish paste generated by segregation. The reasons for this aggressive corrosion attack are not clear, and improving the knowledge on the properties of the segregated grout would help in clarifying this phenomenon. Chemical, physical, and microstructural properties of grouts collected from the ducts of a bridge where segregation occurred are investigated. Results describe the different stages of segregation of the grout and show that the aggressiveness of the whitish grout could be associated with the high content of soluble compounds produced by early hydration of cement, especially alkalis, which lead to pH values exceeding 14.
- 1 June 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 28 (6)
Characterization of Segregated Grout Promoting Corrosion of Posttensioning Tendons
Segregation of grout applied for the protection of posttensioning steel may cause corrosion of steel wires, leading to serious hazards to the safety of posttensioned structures. Several cases of failure of external tendons of bridges have been documented arising from heavily corrosion attacks initiated and propagated in the presence of an unhardened (soft) whitish paste generated by segregation. The reasons for this aggressive corrosion attack are not clear, and improving the knowledge on the properties of the segregated grout would help in clarifying this phenomenon. Chemical, physical, and microstructural properties of grouts collected from the ducts of a bridge where segregation occurred are investigated. Results describe the different stages of segregation of the grout and show that the aggressiveness of the whitish grout could be associated with the high content of soluble compounds produced by early hydration of cement, especially alkalis, which lead to pH values exceeding 14.
- Open Access
- 1 June 2016
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 4, 55-61
Corrosion assessment of reinforced concrete elements of Torre Velasca in Milan
- 1 June 2016
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 4, 55-61
Open AccessCorrosion assessment of reinforced concrete elements of Torre Velasca in Milan
- 31 March 2016
- Published by Wiley in Materials and Corrosion
- Vol. 67 (6) , 573-582
Improving durability of reinforced concrete structures by recycling wet‐ground MSWI bottom ash
Municipal solid waste incineration (MSWI) generates high amounts of bottom ash that, after grinding, could be used as mineral addition for concrete. Wet grinding of the bottom ash can prevent the risk of deleterious expansion due to hydrogen evolution, associated to the presence of metallic aluminium. The pozzolanic behavior of the bottom ash may improve concrete resistance to the penetration of aggressive species. Advantages of recycling wet‐ground MSWI bottom ashes may even be higher when self‐compacting concrete (SCC) is used, which requires large quantity of fine powders (usually more than 500 kg/m3) to prevent segregation of the fresh mix. This paper describes the results of a research aimed at investigating the use of wet‐ground MSWI bottom ashes as mineral additions for the production of self‐compacting concrete. Several types of mineral additions (MSWI bottom ash, coal fly ash, and ground limestone) were used in replacement of 15, 30, and 45% of Portland cement. The results showed that the MSWI ash, added to the mix as a fine slurry obtained by wet‐grinding, led to the production of SCC concrete with compressive strength and resistance to chloride and carbonation similar, or even better, than those of concrete with same amount of coal fly ash.
- 31 March 2016
- Published by Wiley in Materials and Corrosion
- Vol. 67 (6) , 573-582
Improving durability of reinforced concrete structures by recycling wet‐ground MSWI bottom ash
Municipal solid waste incineration (MSWI) generates high amounts of bottom ash that, after grinding, could be used as mineral addition for concrete. Wet grinding of the bottom ash can prevent the risk of deleterious expansion due to hydrogen evolution, associated to the presence of metallic aluminium. The pozzolanic behavior of the bottom ash may improve concrete resistance to the penetration of aggressive species. Advantages of recycling wet‐ground MSWI bottom ashes may even be higher when self‐compacting concrete (SCC) is used, which requires large quantity of fine powders (usually more than 500 kg/m3) to prevent segregation of the fresh mix. This paper describes the results of a research aimed at investigating the use of wet‐ground MSWI bottom ashes as mineral additions for the production of self‐compacting concrete. Several types of mineral additions (MSWI bottom ash, coal fly ash, and ground limestone) were used in replacement of 15, 30, and 45% of Portland cement. The results showed that the MSWI ash, added to the mix as a fine slurry obtained by wet‐grinding, led to the production of SCC concrete with compressive strength and resistance to chloride and carbonation similar, or even better, than those of concrete with same amount of coal fly ash.
- 25 July 2015
- Published by Elsevier in Construction and Building Materials
- Vol. 95, 457-466
Corrosion behaviour of metal inserts in simulated ancient masonry mortars
- 25 July 2015
- Published by Elsevier in Construction and Building Materials
- Vol. 95, 457-466
Corrosion behaviour of metal inserts in simulated ancient masonry mortars
- 1 March 2015
- Published by Elsevier in Construction and Building Materials
- Vol. 79, 245-254
The challenge of the performance-based approach for the design of reinforced concrete structures in chloride bearing environment
- 1 March 2015
- Published by Elsevier in Construction and Building Materials
- Vol. 79, 245-254
The challenge of the performance-based approach for the design of reinforced concrete structures in chloride bearing environment
- 28 August 2014
- Published by Wiley in Materials and Corrosion
- Vol. 66 (8) , 756-762
Macroscopic observations on the long‐term effects of cathodic protection applied to carbonated reinforced concrete
The aim of the paper was to study macroscopic long‐term modifications induced by cathodic protection (CP) applied to carbonated concrete, in order to localise possible deterioration phenomena that can affect the performance of the protection system. Carbonated reinforced specimens that had been subjected to CP for 13 years were analysed with phenolphthalein indicator, that allowed to highlight a pH reduction in the originally alkaline mortar in which the anode was embedded. The pH reduction was localised in the mortar in contact with carbonated concrete, rather than directly in contact with the anode. The thickness of the layer with reduced pH increased with the circulated charge and was nil on specimens that were not subjected to current application. This modification was attributed to a mechanism of dissolution of calcium hydroxide in the mortar. Although a thorough qualitative and quantitative description of the modifications requires further investigations, the results provide a better understanding of possible deterioration phenomena at the anode and they indicate that such phenomena may be hindered by embedding the anode mesh in an adequate layer of alkaline mortar and keeping the current at the least value that is necessary to protect the steel from corrosion.
- 28 August 2014
- Published by Wiley in Materials and Corrosion
- Vol. 66 (8) , 756-762
Macroscopic observations on the long‐term effects of cathodic protection applied to carbonated reinforced concrete
The aim of the paper was to study macroscopic long‐term modifications induced by cathodic protection (CP) applied to carbonated concrete, in order to localise possible deterioration phenomena that can affect the performance of the protection system. Carbonated reinforced specimens that had been subjected to CP for 13 years were analysed with phenolphthalein indicator, that allowed to highlight a pH reduction in the originally alkaline mortar in which the anode was embedded. The pH reduction was localised in the mortar in contact with carbonated concrete, rather than directly in contact with the anode. The thickness of the layer with reduced pH increased with the circulated charge and was nil on specimens that were not subjected to current application. This modification was attributed to a mechanism of dissolution of calcium hydroxide in the mortar. Although a thorough qualitative and quantitative description of the modifications requires further investigations, the results provide a better understanding of possible deterioration phenomena at the anode and they indicate that such phenomena may be hindered by embedding the anode mesh in an adequate layer of alkaline mortar and keeping the current at the least value that is necessary to protect the steel from corrosion.
- 18 August 2014
- Published by Taylor & Francis
- p. 215-221
Durability aspects of electrochemical realkalisation treatment
- 18 August 2014
- Published by Taylor & Francis
- p. 215-221
Durability aspects of electrochemical realkalisation treatment
- Open Access
- 24 July 2014
- Published by Purdue University Press
- p. 363-368
Behavior of CFRP Plate in Simulated ICCP System of Concrete Structures
An innovative effort was made to utilize carbon fiber reinforced polymer (CFRP) plate as an anode in impressed current cathodic protection (ICCP) of reinforced concrete structure. The feasibility was explored by bonding CFRP strips to concrete and then applying protection current through CFRP strips to steel rebar in concrete. Service life and performance of CFRP plate were investigated in simulated ICCP systems with various configurations. Steel potential results confirmed that the steel rebar in concrete maintained at a satisfactory level with the applied protection current. It is shown that CFRP strips can be successfully used in various solutions as an anode material.
- 24 July 2014
- Published by Purdue University Press
- p. 363-368
Open AccessBehavior of CFRP Plate in Simulated ICCP System of Concrete Structures
An innovative effort was made to utilize carbon fiber reinforced polymer (CFRP) plate as an anode in impressed current cathodic protection (ICCP) of reinforced concrete structure. The feasibility was explored by bonding CFRP strips to concrete and then applying protection current through CFRP strips to steel rebar in concrete. Service life and performance of CFRP plate were investigated in simulated ICCP systems with various configurations. Steel potential results confirmed that the steel rebar in concrete maintained at a satisfactory level with the applied protection current. It is shown that CFRP strips can be successfully used in various solutions as an anode material.
- 12 February 2014
- Published by Taylor & Francis in Structure and Infrastructure Engineering
- Vol. 11 (3) , 402-411
Corrosion failure of post-tensioning tendons in alkaline and chloride-free segregated grout: a case study
This paper describes a case study of corrosion of post-tensioning strands in segregated grout that led to failure of one of the external tendons of a bridge after less than 2 years from the construction. Unexpectedly, severe corrosion attacks took place in areas where the ducts were filled by the injection grout, but segregation of the grout led to the presence of an unhardened whitish paste. A detailed inspection of the failed tendon, as well as other tendons removed afterwards, showed that corrosion occurred mainly in the inclined parts of the external post-tensioning tendons, in the presence of whitish grout. Analysis on samples of segregated grout showed that it was highly alkaline and had a high content of sulphate ions, but was free of chloride ions, excluding thus the normal causes of corrosion of steel in cement-based materials. Microstructural analysis of failed wires also excluded the failure for hydrogen embrittlement.
- 12 February 2014
- Published by Taylor & Francis in Structure and Infrastructure Engineering
- Vol. 11 (3) , 402-411
Corrosion failure of post-tensioning tendons in alkaline and chloride-free segregated grout: a case study
This paper describes a case study of corrosion of post-tensioning strands in segregated grout that led to failure of one of the external tendons of a bridge after less than 2 years from the construction. Unexpectedly, severe corrosion attacks took place in areas where the ducts were filled by the injection grout, but segregation of the grout led to the presence of an unhardened whitish paste. A detailed inspection of the failed tendon, as well as other tendons removed afterwards, showed that corrosion occurred mainly in the inclined parts of the external post-tensioning tendons, in the presence of whitish grout. Analysis on samples of segregated grout showed that it was highly alkaline and had a high content of sulphate ions, but was free of chloride ions, excluding thus the normal causes of corrosion of steel in cement-based materials. Microstructural analysis of failed wires also excluded the failure for hydrogen embrittlement.