Impact of anatomical and functional severity of coronary atherosclerotic plaques on the transmural perfusion gradient: a [15O]H2O PET study
Open Access
- 29 April 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 35 (31) , 2094-2105
Abstract
Myocardial ischaemia occurs principally in the subendocardial layer, whereas conventional myocardial perfusion imaging provides no information on the transmural myocardial blood flow (MBF) distribution. Subendocardial perfusion measurements and quantification of the transmural perfusion gradient (TPG) could be more sensitive and specific for the detection of coronary artery disease (CAD). The current study aimed to determine the impact of lesion severity as assessed by the fractional flow reserve (FFR) on subendocardial perfusion and the TPG using [15O]H2O positron emission tomography (PET) imaging in patients evaluated for CAD. Sixty-six patients with anginal chest pain were prospectively enrolled and underwent [15O]H2O myocardial perfusion PET imaging. Subsequently, invasive coronary angiography was performed and FFR obtained in all coronary arteries irrespective of the PET imaging results. Thirty (45%) patients were diagnosed with significant CAD (i.e. FFR ≤0.80), whereas on a per vessel analysis (n = 198), 53 (27%) displayed a positive FFR. Transmural hyperaemic MBF decreased significantly from 3.09 ± 1.16 to 1.67 ± 0.57 mL min−1 g−1 (P < 0.001) in non-ischaemic and ischaemic myocardium, respectively. The TPG decreased during hyperaemia when compared with baseline (1.20 ± 0.14 vs. 0.94 ± 0.17, P < 0.001), and was lower in arteries with a positive FFR (0.97 ± 0.16 vs. 0.88 ± 0.18, P < 0.01). A TPG threshold of 0.94 yielded an accuracy to detect CAD of 59%, which was inferior to transmural MBF with an optimal cutoff of 2.20 mL min−1 g−1 and an accuracy of 85% (P < 0.001). Diagnostic accuracy of subendocardial perfusion measurements was comparable with transmural MBF (83 vs. 85%, respectively, P = NS). Cardiac [15O]H2O PET imaging is able to distinguish subendocardial from subepicardial perfusion in the myocardium of normal dimensions. Hyperaemic TPG is significantly lower in ischaemic myocardium. This technique can potentially be employed to study subendocardial perfusion impairment in more detail. However, the diagnostic accuracy of subendocardial hyperaemic perfusion and TPG appears to be limited compared with quantitative transmural MBF, warranting further study.Keywords
This publication has 35 references indexed in Scilit:
- Assessment of Coronary Artery Stenosis Severity and LocationJACC: Cardiovascular Imaging, 2013
- Feasibility of subendocardial and subepicardial myocardial perfusion measurements in healthy normals with 15O-labeled water and positron emission tomographyJournal of Nuclear Cardiology, 2011
- Why is the subendocardium more vulnerable to ischemia? A new paradigmAmerican Journal of Physiology-Heart and Circulatory Physiology, 2011
- Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scannerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2011
- Low-Dose Quantitative Myocardial Blood Flow Imaging Using 15O-Water and PET Without Attenuation CorrectionJournal of Nuclear Medicine, 2010
- Adenosine Stress 64- and 256-Row Detector Computed Tomography Angiography and Perfusion ImagingCirculation: Cardiovascular Imaging, 2009
- Determinants of coronary microvascular dysfunction in symptomatic hypertrophic cardiomyopathyAmerican Journal of Physiology-Heart and Circulatory Physiology, 2008
- Is subendocardial ischaemia present in patients with chest pain and normal coronary angiograms? A cardiovascular MR studyEuropean Heart Journal, 2007
- Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the HeartCirculation, 2002
- Magnetic Resonance Imaging of Myocardial Perfusion in Single-Vessel Coronary Artery Disease: Implications for Transmural Assessment of Myocardial PerfusionJournal of Cardiovascular Magnetic Resonance, 2000