TFTiago Bravo Ferreira

Tiago Bravo Ferreira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tiago Bravo Ferreira has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of Daily Visual Habits in a Presbyopic Population

    by Filomena Ribeiro, Tiago B. Ferreira, Diana Silva, Ana Cláudia Matos, Sylvia Gaspar, David P. Piñero

    Purpose. To evaluate and report the visual habits and requirements of a sample of presbyopic patients using an advanced sensor. Methods. Transversal study collecting clinical data from 40 presbyopes candidates for presbyopia‐correction intraocular lens (IOL) implantation with mean age of 61.0 years (43–80 years). A complete ophthalmological examination was performed in all patients including visual, refractive, an ocular biometric analysis. Furthermore, patients were instructed about the use of the Vivior Monitor system (Vivior AG, Zürich, Switzerland), which consists of a series of sensors attached to the rim of the patient’s glasses that capture information about the visual behavior of the patient. This device was worn for a period of 36 hours or more. The data collected were transferred to a database and analyzed. Results. Mean percentages of time dedicated to distance, intermediate, and near vision were 27.25 ± 11.93% (5–65%), 30.23 ± 9.36% (12–50%), and 42.53 ± 14.96% (13–78%), respectively. Mean percentages of time performing activities under photopic, mesopic, and scotopic conditions were 37.08 ± 23.20% (5–87%), 33.65 ± 13.84% (6–67%), and 29.28 ± 17.03% (4–65%). The percentage of time with digital screens ranged from 2% to 48%. Age was significantly correlated with the percentage of time dedicated to distance vision (r = 0.317, p = 0.047) and to activities performed under photopic conditions (r = −0.344, p = 0.030). Conclusions. Distance and illumination conditions used to perform different daily life visual activities vary significantly among presbyopes, with a trend to the dedication of more time to intermediate and near visual activities performed under photopic and mesopic conditions. Data interpretation should be done with care until a proper validation of the device used.


  • Comparison of refractive and visual outcomes of 3 presbyopia-correcting intraocular lenses

    by Tiago B Md Ferreira, Filomena J MD Ribeiro, Diana Co Silva, Ana Cláudia Co Matos, Sylvia Co Gaspar, Soraia Co Almeida

    Purpose: To evaluate and compare the clinical outcomes after cataract surgery with implantation of 3 types of trifocal diffractive intraocular lenses (IOLs). Setting: Hospital da Luz, Lisbon, Portugal. Design: Prospective comparative case series. Methods: Patients undergoing phacoemulsification cataract surgery with implantation of 1 of the 3 trifocal IOLs were enrolled: TECNIS Synergy (Synergy group, 30 patients), Acrysof PanOptix (PanOptix group, 30 patients), and POD F (Finevision group, 30 patients). The outcomes of distance, intermediate, and near visual acuity (VA), refraction, defocus curve, photic phenomena, and spectacle independence were evaluated at the 3-month follow-up. Results: 180 eyes of 90 patients were enrolled. No statistically significant differences were found between groups in monocular distance-corrected intermediate (Synergy group 0.04 ± 0.11, PanOptix group 0.05 ± 0.09, and Finevision group 0.08 ± 0.10; P = .107) and near VA (0.01 ± 0.08, 0.01 ± 0.06, and 0.04 ± 0.10, respectively; P = .186). Similarly, no statistically significant differences among groups were found in binocular uncorrected distance (P = .572), near (P = .929), and intermediate VA (P = .327). By contrast, statistically significant differences between groups were found in the visual acuity for the vergence demands of −0.50, −1.00, −2.00, −3.50, and −4.00 diopters (P ≤ .045). No statistically significant differences among groups were found in the frequency, severity, and bothersomeness of different disturbing visual symptoms, including glare and halos (P ≥ .129). More than 87 (96%) of patients in all groups did not require the use of spectacles at any distance postoperatively. Conclusions: The 3 trifocal IOLs evaluated provided an effective visual rehabilitation with minimal incidence of photic phenomena. A trend to obtain a wider range of functional focus was observed with the TECNIS Synergy IOL.


  • Visual outcomes and patient satisfaction after implantation of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and multifocal profiles

    by Filomena J MD Ribeiro, Tiago B MD Ferreira, Diana Orthoptist Silva, Ana Cláudia Orthoptist Matos, Sylvia Orthoptist Gaspar

    Purpose: To evaluate clinical outcomes delivered by a new hybrid presbyopia-correcting intraocular lens (IOL): TECNIS Synergy ZFR00V IOL model (Johnson & Johnson Vision). Setting: Hospital da Luz Lisboa, Lisbon, Portugal. Design: Prospective observational study. Methods: Patients undergoing bilateral IOL implantation were included. Visual acuity (VA) was measured for far distance, intermediate (66 cm), and near (40 cm) vision under both photopic and mesopic conditions. In addition, at the 3-month follow-up visit, the defocus curve was obtained for binocular vision, and questionnaires were administered to measure spectacle independence and level of satisfaction ( quality of vision and Catquest-SF9) with the surgical outcomes. Results: 54 eyes of 27 patients were included. At the 3-month follow-up, under photopic conditions, VA values were as follows: corrected distance VA (CDVA) = −0.02 ± 0.07, distance-corrected intermediate VA = 0.03 ± 0.11, and distance-corrected near VA (DCNVA) = 0.00 ± 0.08, whereas under mesopic conditions, VA values were as follows: CDVA = −0.01 ± 0.05 and DCNVA = 0.07 ± 0.09. The binocular defocus curve revealed that mean VA was better than 0.30 logMAR within the +1.00 to −4.00 diopters (D) interval, and better than 0.10 logMAR between +0.50 and −3.00 D. All patients achieved distance vision spectacle freedom, whereas 3.7% of them said they used them in certain intermediate or near vision situations. As much as 88% of the patients reported being fairly satisfied or very satisfied. Conclusions: The TECNIS Synergy ZFR00V IOL model used for cataract surgery is capable of restoring visual function while providing very good intermediate and near vision, under both photopic and mesopic conditions, resulting in a high level of patient satisfaction.


  • Open Access

    How Can We Improve Toric Intraocular Lens Calculation Methods? Current Insights

    by Tiago B Ferreira, Filomena Ribeiro

    In this paper, we review current strategies for calculating toric intraocular lenses (IOLs). We discuss the prevalence and clinical relevance of astigmatism and the assessment of toric IOL candidates. We detail recommendations for evaluating astigmatism and current biometry and IOL power calculation techniques. Finally, error sources and results of current toric IOL calculators are discussed.


  • Comparison of clinical outcomes of 3 trifocal IOLs

    by Filomena MD Ribeiro, Tiago B Md Ferreira

    Purpose: To compare the clinical outcomes obtained after implantation of 1 of 3 models of diffractive trifocal IOLs. Setting: Hospital da Luz, Lisbon, Portugal. Design: Prospective randomized comparative study. Methods: Patients undergoing cataract surgery with bilateral implantation of 1 of 3 models of diffractive trifocal IOLs were enrolled. The IOL models implanted were the FineVision POD F, RayOne Trifocal, or the AcrySof IQ PanOptix IOL (30 eyes of 15 patients in each group). Visual acuity (VA), refraction, defocus curve, and contrast sensitivity outcomes were evaluated during a 3-month follow-up. Furthermore, the Quality of Vision questionnaire (QoV) was used to evaluate the frequency, severity, and discomfort of different visual symptoms. Results: A total of 90 eyes of 45 patients were included. No statistically significant differences were found between groups in distance, intermediate, and near VA (P ≥ .112) and postoperative refraction (P ≥ .059). Postoperative binocular uncorrected intermediate VA of 0.10 logarithm of the minimum angle of resolution (logMAR) or better was found in 14 (93.33%) patients in the 3 groups. Postoperative binocular uncorrected near VA of 0.10 logMAR or better was found in 13 (86.67%), 14 (93.33%), and 13 (86.67%) patients in the POD F, RayOne, and PanOptix IOLs groups, respectively. No statistically significant differences were found between groups in scotopic contrast sensitivity with and without glare and in the QoV scores (P ≥ .057), except for the difference between the POD F and RayOne IOLs groups in depth perception severity, which was less in the RayOne IOL group (P = .019). Conclusions: The 3 trifocal IOLs evaluated provided a complete visual restoration with good visual quality outcomes.


  • Open Access

    Predictability of different calculators in the minimization of postoperative astigmatism after implantation of a toric intraocular lens

    by Filomena J Ribeiro, Tiago B Ferreira, Catarina Relha, Carina Esteves, Sylvia Gaspar

    Purpose: To assess the efficacy of five calculators for toric intraocular lenses (IOL). Methods: Retrospective comparative case series in cataract patients undergoing implantation of trifocal toric IOLs (PhysIOL FineVision POD FT). Inclusion criteria were age-related cataract and a corneal astigmatism between 0.90D and 4.50D. Refractive astigmatism predictability of five different toric calculators or calculation methods were compared. Furthermore, two groups were differentiated according to the type of astigmatism. The mean absolute error and the centroid errors in the predicted residual astigmatism from each calculator were evaluated. Results: Fifty-one eyes of 43 patients were included in the study. For the standard toric calculator using anterior keratometry values only, the centroid prediction error was 0.39D±0.41@166º, which was reduced by the application of the PhysIOL toric calculator that includes the Abulafia-Koch regression formula and adjustment for the effective lens position (0.05D±0.34@167º), and also by the application of the Barrett toric calculator (0.07D±0.28@160º). Regarding the techniques that directly evaluate posterior corneal surface, the Holladay toric calculator, using total corneal power provided by a color-LED topographer, generated better results (0.10D±0.44@156º) than those using Scheimpflug camera data (0.23D±0.56@158º). Similar results were found for both types of astigmatism. Conclusion: The PhysIOL and the Barrett toric calculators taking into account the posterior corneal astigmatism by mathematical models, yielded lower astigmatic prediction errors compared to a standard toric calculator based on anterior keratometry data only. When total corneal power measurements were used, prediction errors were lower with color-LED than with Scheimpflug based topography.


  • Prospective Comparison of Clinical Performance and Subjective Outcomes Between Two Diffractive Trifocal Intraocular Lenses in Bilateral Cataract Surgery

    by Tiago B. Ferreira, Filomena J. Ribeiro

    PURPOSE: To compare clinical outcomes and subjective experience after bilateral implantation of two non-toric diffractive trifocal intraocular lenses (IOLs). METHODS: In a prospective, comparative case series, patients were randomly allocated to receive bilateral implantation of either the preloaded RayOne Trifocal (Rayner, Worthing, UK) or the FineVision POD F (PhysIOL, Liège, Belgium). At the 3-month follow-up, the main outcomes were monocular and binocular uncorrected and corrected distance (UDVA, CDVA), intermediate at 80 cm (UIVA, DCIVA), and near at 40 cm (UNVA, DCNVA) visual acuities, refractive outcomes, and defocus curves. Patients' satisfaction in terms of visual disturbance was also evaluated. RESULTS: Each group comprised 30 eyes (15 patients). The mean monocular UDVA was 0.03 ± 0.11 (RayOne Trifocal) and 0.04 ± 0.08 (FineVision POD F) logMAR ( P = .605); DCIVA was 0.05 ± 0.13 and 0.05 ± 0.10 logMAR, respectively ( P > .999); and DCNVA was 0.02 ± 0.12 and 0.03 ± 0.11 logMAR ( P = .742). A better manifest spherical equivalent was found in the RayOne Trifocal than in the FineVision POD F group ( P = .035) and depth perception issues were less severe with the RayOne Trifocal IOL ( P = .042). There was no significant difference in other photic phenomena between groups. CONCLUSIONS: Both IOLs provided good visual outcomes at all distances with no differences between the groups. Refractive accuracy was better for the RayOne Trifocal IOL. The results indicated that the new trifocal IOL may represent a safe and effective option for presbyopic patients. [ J Refract Surg. 2019;35(7):418–425.]


  • Comparison of Surgically Induced Astigmatism and Morphologic Features Resulting From Femtosecond Laser and Manual Clear Corneal Incisions for Cataract Surgery

    by Tiago B. Ferreira, Filomena J. Ribeiro, João Pinheiro, Paulo Ribeiro, João G. O'NEill

    PURPOSE: To compare the surgically induced astigmatism (SIA) vector, flattening effect, torque, and wound architecture following femtosecond laser and manual clear corneal incisions (CCIs). METHODS: In a double-armed, randomized, prospective case series, cataract surgery was performed for 600 eyes using femtosecond laser (300 eyes) or manual (300 eyes) 2.4-mm CCIs in temporal or superior oblique locations. SIA, flattening effect, torque, and the summated vector mean for SIA were calculated. Correlation with individual features was established and incision morphology was investigated by anterior segment optical coherence tomography at 3 months of follow-up. RESULTS: The SIA, flattening effect, and torque were lower in the femtosecond laser group for both incision locations, although the differences were not significant (all P > .05). The femtosecond laser group showed less dispersion of SIA magnitude and flattening effect. Temporal and superior oblique incisions resulted in flattening effect values of −0.11 and −0.21 diopters (D), respectively, in the femtosecond laser group and −0.13 and −0.34 D, respectively, in the manual group. Significant correlations with individual features were only found in the femtosecond laser group, with preoperative astigmatism being the only significant SIA predictor by multiple regression analysis ( P = .003). Femtosecond laser CCIs showed less deviation from the intended length, wound enlargement, endothelial misalignment, and Descemet membrane detachments (all P < .037). CONCLUSIONS: Femtosecond laser CCIs were more reproducible. Although SIAs were smaller in femtosecond laser CCIs than in manual CCIs for both temporal and superior oblique incisions, the difference was not statistically significant. Association with individual features is highly variable. [ J Refract Surg. 2018;34(5):322–329.]


  • Comparative analysis of clinical outcomes of a monofocal and an extended-range-of-vision intraocular lens in eyes with previous myopic laser in situ keratomileusis

    by Tiago B. Ferreira, João Pinheiro, Leyre Zabala, Filomena J. Ribeiro

    To compare the clinical outcomes after cataract surgery with implantation of a monofocal or an extended-range-of-vision intraocular lens (IOL). Hospital da Luz, Lisbon Portugal. Prospective case series. Patients who previously had myopic laser in situ keratomileusis (LASIK) had cataract surgery with bilateral implantation of an extended-range-of-vision IOL (Tecnis Symfony) or a monofocal IOL (Tecnis ZCB00). Visual acuity, refraction, defocus curve, contrast sensitivity, photic phenomena, spectacle independence, and patient satisfaction were evaluated at 4 months postoperatively. The study comprised 44 patients (88 eyes), with 22 patients in each IOL group. No significant differences between groups were found postoperatively for most visual and refractive parameters (all P ≥ .27). However, binocular uncorrected intermediate and near visual acuities were significantly better in the extended-range-of-vision group (P < .01). The defocus curve of both IOLs differed more with increasing negative defocus (P < .01). No significant differences between IOLs were found in contrast sensitivity for any spatial frequency evaluated (P ≥ .05). Most of the patients did not perceive photic phenomena with either IOL. Mild glare was reported in 22.7% of the extended-range-of-vision patients and 9.1% of the monofocal group; mild halos were comparable with 13.6% in both groups. Spectacle dependence for intermediate vision and near vision was higher in the monofocal IOL group. The extended-range-of-vision IOL was a useful option to restore visual function after cataract surgery in eyes that previously had myopic LASIK surgery, offering levels of visual quality comparable to those achieved with the monofocal IOL.


  • Open Access

    Comparability and repeatability of different methods of corneal astigmatism assessment

    by Tiago B Ferreira, Filomena J Ribeiro

    Comparability and repeatability of different methods of corneal astigmatism assessment Tiago B Ferreira, Filomena J Ribeiro Department of Ophthalmology, Hospital da Luz, Lisbon, Portugal Purpose: To assess the comparability and repeatability of keratometric and astigmatism values measured by four techniques: Orbscan IIz® (Bausch and Lomb), Lenstar LS 900® (Haag-Streit), Cassini® (i-Optics), and Total Cassini (anterior + posterior surface), in healthy volunteers.Patients and methods: Fifteen healthy volunteers (30 eyes) were assessed by the four techniques. In each eye, three consecutive measures were performed by the same operator. Keratometric and astigmatism values were recorded. The intraclass correlation coefficient (ICC) was used to assess comparability and repeatability. Agreement between measurement techniques was evaluated with Bland–Altman plots.Results: Comparability was high between all measurement techniques for minimum keratometry (K1), maximum keratometry (K2), astigmatism magnitude, and astigmatism axis, with ICC >0.900, except for astigmatism magnitude measured by Cassini compared to Lenstar (ICC =0.798) and Orbscan compared to Lenstar (ICC =0.810). However, there were some differences in the median values of K1 and K2 between measurement techniques, and the Bland–Altman plots showed a wide data spread for all variables, except for astigmatism magnitude measured by Cassini and Total Cassini. For J0 and J45, comparability was only high for J0 between Cassini and Orbscan. Repeatability was also high for all measurement techniques except for K2 (ICC =0.814) and J45 (ICC =0.621) measured by Cassini.Conclusion: All measurement techniques showed high comparability regarding K1, K2, and astigmatism axis. Although posterior corneal surface is known to influence these measurements, comparability was high between Cassini and Total Cassini regarding astigmatism magnitude and axis. However, the wide data spread suggests that none of these devices should be used interchangeably. Keywords: astigmatism, keratometry, topography, repeatability, comparability