API Content and Blend Uniformity Using Quantum Cascade Laser Spectroscopy Coupled with Multivariate Analysis
Authors:
- Vladimir Villanueva-LópezVVVladimir Villanueva-López
- Leonardo C. Pacheco-LondoñoLPLeonardo C. Pacheco-Londoño
- Reynaldo Villarreal-GonzálezRVReynaldo Villarreal-González
- John R. Castro-SuarezJCJohn R. Castro-Suarez
- Andrés Román-OspinoARAndrés Román-Ospino
- William Ortiz-RiveraWOWilliam Ortiz-Rivera
- Nataly J. Galán-FreyleNGNataly J. Galán-Freyle
- Samuel P. Hernandez-RiveraSamuel P. Hernandez-Rivera
Open Access
- 29 June 2021
- journal article
- research article
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (7) , 985
Abstract
The process analytical technology (PAT) initiative proposed by the US Food and Drug Administration (FDA) suggests innovative methods to better understand pharmaceutical processes. The development of analytical methods that quantify active pharmaceutical ingredients (APIs) in powders and tablets is fundamental to monitoring and controlling a drug product’s quality. Analytical methods based on vibrational spectroscopy do not require sample preparation and can be implemented during in-line manufacturing to maintain quality at each stage of operations. In this study, a mid-infrared (MIR) quantum cascade laser (QCL) spectroscopy-based protocol was performed to quantify ibuprofen in formulations of powder blends and tablets. Fourteen blends were prepared with varying concentrations from 0.0% to 21.0% (w/w) API. MIR laser spectra were collected in the spectral range of 990 to 1600 cm−1. Partial least squares (PLS) models were developed to correlate the intensities of vibrational signals with API concentrations in powder blends and tablets. PLS models were evaluated based on the following figures of merit: correlation coefficient (R2), root mean square error of calibration, root mean square error of prediction, root mean square error of cross-validation, and relative standard error of prediction. QCL assisted by multivariate analysis was demonstrated to be accurate and robust for analysis of the content and blend uniformity of pharmaceutical compounds.Keywords
Funding Information
- U.S. Department of War (W911NF-11-1-0152)
- Defense Threat Reduction Agency (DODRIF11-DTRA020-P-0017)
- U.S. Department of Homeland Security (2013-ST-061-ED0001)
This publication has 33 references indexed in Scilit:
- Application of mid-IR spectroscopy for the characterization of pharmaceutical systemsInternational Journal of Pharmaceutics, 2011
- Preformulation studies on grewia gum as a formulation excipientJournal of Thermal Analysis and Calorimetry, 2011
- Simultaneous determination of ibuprofen and paracetamol using derivatives of the ratio spectra methodArabian Journal of Chemistry, 2011
- A review of near infrared spectroscopy and chemometrics in pharmaceutical technologiesJournal of Pharmaceutical and Biomedical Analysis, 2007
- Pharmaceutical applications of Mid-IR and Raman spectroscopyAdvanced Drug Delivery Reviews, 2005
- Quantitation of active pharmaceutical ingredients and excipients in powder blends using designed multivariate calibration models by near-infrared spectroscopyInternational Journal of Pharmaceutics, 2005
- Solid-phase microextraction and chiral HPLC analysis of ibuprofen in urineJournal of Chromatography B, 2005
- A novel method for analyzing thick tablets by near infrared spectroscopyAAPS PharmSciTech, 2001
- High power mid-infrared (λ∼5 μm) quantum cascade lasers operating above room temperatureApplied Physics Letters, 1996
- Rapid HPLC‐Determination of Ibuprofen and Flurbiprofen in Plasma for Therapeutic Drug Control and Pharmacokinetic ApplicationsActa Pharmacologica et Toxicologica, 1986