Andrés Román-Ospino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrés Román-Ospino has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- John R. Castro-Suarez
ALERT DHS Center of Excellence for Explosives Research, Department of Chemistry, University of Puerto Rico, Mayagüez, PR 00681, USA
1 shared publication - Leonardo C. Pacheco-Londono
Centro de Investigaciones en Ciencias de la Vida, Facultad de Ciencias Básicas y Biomedicas, Universidad Simón Bolívar, Barranquilla 080002, Colombia
1 shared publication - Nataly J. Galan-Freyle
Facultad de Ciencias Básicas y Biomédicas, Life Science Research Center, Universidad Simón Bolívar, Barranquilla 080002, Colombia
1 shared publication - Reynaldo Villarreal-González
AudacIA Center, Universidad Simón Bolívar, Barranquilla 080002, Colombia
1 shared publication - Samuel P. Hernandez-Rivera
Center for Chemical Sensors (CCS), Chemical Imaging and Surface Analysis Center (CISAC), Department of Chemistry, University of Puerto Rico-Mayagüez, Mayagüez, PR 00681, USA
1 shared publication - Vladimir Villanueva-López
ALERT DHS Center of Excellence for Explosives Research, Department of Chemistry, University of Puerto Rico, Mayagüez, PR 00681, USA
1 shared publication
Latest Publications
- Open Access
- 29 June 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (7) , 985
API Content and Blend Uniformity Using Quantum Cascade Laser Spectroscopy Coupled with Multivariate Analysis
The process analytical technology (PAT) initiative proposed by the US Food and Drug Administration (FDA) suggests innovative methods to better understand pharmaceutical processes. The development of analytical methods that quantify active pharmaceutical ingredients (APIs) in powders and tablets is fundamental to monitoring and controlling a drug product’s quality. Analytical methods based on vibrational spectroscopy do not require sample preparation and can be implemented during in-line manufacturing to maintain quality at each stage of operations. In this study, a mid-infrared (MIR) quantum cascade laser (QCL) spectroscopy-based protocol was performed to quantify ibuprofen in formulations of powder blends and tablets. Fourteen blends were prepared with varying concentrations from 0.0% to 21.0% (w/w) API. MIR laser spectra were collected in the spectral range of 990 to 1600 cm−1. Partial least squares (PLS) models were developed to correlate the intensities of vibrational signals with API concentrations in powder blends and tablets. PLS models were evaluated based on the following figures of merit: correlation coefficient (R2), root mean square error of calibration, root mean square error of prediction, root mean square error of cross-validation, and relative standard error of prediction. QCL assisted by multivariate analysis was demonstrated to be accurate and robust for analysis of the content and blend uniformity of pharmaceutical compounds.
- 29 June 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (7) , 985
Open AccessAPI Content and Blend Uniformity Using Quantum Cascade Laser Spectroscopy Coupled with Multivariate Analysis
The process analytical technology (PAT) initiative proposed by the US Food and Drug Administration (FDA) suggests innovative methods to better understand pharmaceutical processes. The development of analytical methods that quantify active pharmaceutical ingredients (APIs) in powders and tablets is fundamental to monitoring and controlling a drug product’s quality. Analytical methods based on vibrational spectroscopy do not require sample preparation and can be implemented during in-line manufacturing to maintain quality at each stage of operations. In this study, a mid-infrared (MIR) quantum cascade laser (QCL) spectroscopy-based protocol was performed to quantify ibuprofen in formulations of powder blends and tablets. Fourteen blends were prepared with varying concentrations from 0.0% to 21.0% (w/w) API. MIR laser spectra were collected in the spectral range of 990 to 1600 cm−1. Partial least squares (PLS) models were developed to correlate the intensities of vibrational signals with API concentrations in powder blends and tablets. PLS models were evaluated based on the following figures of merit: correlation coefficient (R2), root mean square error of calibration, root mean square error of prediction, root mean square error of cross-validation, and relative standard error of prediction. QCL assisted by multivariate analysis was demonstrated to be accurate and robust for analysis of the content and blend uniformity of pharmaceutical compounds.