Calibration Alignment Sensitivity in Corneal Terahertz Imaging
Authors:
- Faezeh ZarrinkhatFZFaezeh Zarrinkhat
- Mariangela BaggioMBMariangela Baggio
- Joel LambergJLJoel Lamberg
- Aleksi TamminenATAleksi Tamminen
- Irina NefedovaINIrina Nefedova
- Juha Ala-LaurinahoJAJuha Ala-Laurinaho
- Elsayed E. M. KhaledEKElsayed E. M. Khaled
- Juan M. RiusJRJuan M. Rius
- Jordi RomeuJRJordi Romeu
- Zachary TaylorZTZachary Taylor
Open Access
Abstract
Improving the longitudinal modes coupling in layered spherical structure contributes significantly to corneal terahertz sensing, which plays a crucial role in the early diagnosis of cornea dystrophies. Using a steel sphere to calibrate reflection from the cornea sample assists in enhancing the resolution of longitudinal modes. The requirement and challenges toward applying the calibration sphere are introduced and addressed. Six corneas with different properties are spotted to study the effect of perturbations in the calibration sphere in a frequency range from 100 GHz to 600 GHz. A particle-swarm optimization algorithm is employed to quantify corneal characteristics considering cases of accurately calibrated and perturbed calibrated scenarios. For the first case, the study is carried out with signal-to-noise values of 40 dB, 50 dB and 60 dB at waveguide bands WR-, WR-, and WR-. As expected, better estimation is achieved in high-SNR cases. Furthermore, the lower waveguide band is revealed as the most proper band for the assessment of corneal features. For perturbed cases, the analysis is continued for the noise level of 60 dB in the three waveguide bands. Consequently, the error in the estimation of corneal properties rises significantly (around ).
Keywords
Funding Information
- Agencia Estatal de Investigación (PID2019-107885GB-C31/AEI/10.13039, PRE2018-084326)
- Research Council of Finland (327640)
This publication has 18 references indexed in Scilit:
- In vivo estimation of water diffusivity in occluded human skin using terahertz reflection spectroscopyJournal of Biophotonics, 2018
- THz Imaging System for in vivo Human CorneaIEEE Transactions on Terahertz Science and Technology, 2017
- Optical System Design for Noncontact, Normal Incidence, THz Imaging of in vivo Human CorneaIEEE Transactions on Terahertz Science and Technology, 2017
- Millimeter-Wave Tissue Diagnosis: The Most Promising Fields for Medical ApplicationsIEEE Microwave Magazine, 2015
- THz and mm-Wave Sensing of Corneal Tissue Water Content: In Vivo Sensing and Imaging ResultsIEEE Transactions on Terahertz Science and Technology, 2015
- THz and mm-Wave Sensing of Corneal Tissue Water Content: Electromagnetic Modeling and AnalysisIEEE Transactions on Terahertz Science and Technology, 2015
- Scattering of electromagnetic radiation by a multilayered sphereComputer Physics Communications, 2009
- Light scattering by a coated sphere illuminated with a Gaussian beamApplied Optics, 1994
- Scattered and internal intensity of a sphere illuminated with a Gaussian beamIEEE Transactions on Antennas and Propagation, 1993
- WATER GRADIENTS ACROSS BOVINE CORNEA1988