Comparison of toric intraocular lens alignment error with different toric markers
Authors:
- 1 November 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (11) , 1597-1601
Abstract
To compare the error in intraocular lens (IOL) toric alignment of 2 toric markers. Sir Charles Gairdner Hospital, Perth, Western Australia, Australia. Retrospective case series. Two consecutive groups of patients had cataract surgery with implantation of an AcrySof SN6A toric IOL (versions T2-T8) by the same surgeon at 2 public hospitals. The only difference in the toric alignment method between the groups was the toric maker used (Group 1: Barrett dual axis toric marker; Group 2: Mendez gauge). A mobile phone application (toriCAM) was used in both groups to determine the reference meridian. The primary outcome measure was the error in toric IOL alignment in degrees at 1 month. The secondary outcome measure was the percentage of eyes achieving a manifest refraction astigmatism within ±0.50 diopter (D) at 1 month. Seventy-two eyes of 56 patients were included (Group 1: 36 eyes of 35 patients; Group 2: 36 eyes of 25 patients). The mean absolute toric alignment error (intended versus achieved axis of alignment) was 4.0 degrees ± 2.9 (SD) in Group 1 and 8.4 ± 6.5 degrees in Group 2 (P = .0015). Twenty-nine eyes (80.6%) in Group 1 and 21 eyes (53.8%) in Group 2 achieved a manifest refractive astigmatism of 0.50 D or less (P < .05). Toric IOL alignment using the mobile phone application was more accurate with the Barrett dual axis toric marker than with the commonly used Mendez gauge, with a significantly higher percentage of eyes achieving a manifest refraction astigmatism within ±0.50 D.Keywords
This publication has 16 references indexed in Scilit:
- Axis Misalignment of Toric Intraocular Lens: Placement Error and Postoperative RotationOphthalmology, 2017
- Accuracy of toric intraocular lens axis alignment using a 3-dimensional computer-guided visualization systemJournal of Cataract & Refractive Surgery, 2016
- Toric Intraocular Lenses in the Correction of Astigmatism During Cataract SurgeryOphthalmology, 2016
- Clinical Outcomes of TECNIS Toric Intraocular Lens Implantation after Cataract Removal in Patients with Corneal AstigmatismOphthalmology, 2015
- Axis measurement strip for Haag-Streit BM900 series slitlampJournal of Cataract & Refractive Surgery, 2014
- Evaluation of 4 corneal astigmatic marking methodsJournal of Cataract & Refractive Surgery, 2012
- Visual acuity improvements after implantation of toric intraocular lenses in cataract patients with astigmatism: a systematic reviewBMC Ophthalmology, 2012
- Residual astigmatism produced by toric intraocular lens rotationJournal of Cataract & Refractive Surgery, 2011
- Accuracy of toric intraocular lens implantation in cataract and refractive surgeryJournal of Cataract & Refractive Surgery, 2011
- New Axis-Marking Method for a Toric Intraocular Lens: Mapping MethodJournal of Refractive Surgery, 2011