Scleral Fixation of Single-Piece Foldable IOL Using Double-Flanged Technique
Open Access
- 1 October 2020
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 3131-3136
Abstract
Purpose: To describe the efficiency and visual results of a new method of transconjunctival intrascleral fixation of single-piece foldable IOL using double-flanged 6/0 prolene suture. Materials and Methods: Seventeen aphakic eyes of 17 patients without adequate capsular support were involved in this study. Lens was prepared by passing the 6/0 prolene suture in a track in the haptic of single-piece foldable IOL created by 31 g needle. The 6/0 prolene suture was retrieved through a 30 g needle transconjunctivally to outside the globe; then, IOL was implanted and a terminal bulb was created at the outer end of the prolene suture. Results: All cases were aphakic after complicated phacoemulsification. In 10 cases hydrophilic IOLs were used and in 7 cases hydrophobic IOLs were used. There is clear statistically significant difference between pre-UCVA and post- UCVA. Complications included suture slippage in 2 cases and prolene bulb exposure in one case. There was no significant difference in endothelial cell count and IOP before and after 3 months. Conclusion: Transconjunctival intrascleral fixation of foldable single-piece IOLs is a safe efficient method for correcting aphakia.Keywords
This publication has 12 references indexed in Scilit:
- Double-Flanged polypropylene Suture for Scleral Fixation of Cionni Capsule Tension RingClinical Ophthalmology, 2020
- Novel double-flanged technique for managing Marfan syndrome and microspherophakiaJournal of Cataract & Refractive Surgery, 2020
- Scleral fixation of a single-piece foldable acrylic IOL through a 1.80 mm corneal incisionJournal of Cataract & Refractive Surgery, 2020
- 27-GAUGE SUTURELESS INTRASCLERAL FIXATION OF INTRAOCULAR LENSES WITH HAPTIC FLANGINGRetina, 2019
- Surgical Technique for Sutureless Intrascleral Fixation of a 3-Piece Intraocular Lens Using a 30-Gauge NeedleRetina, 2019
- Reinforced scleral fixation of foldable intraocular lens by double sutures: comparison with intrascleral intraocular lens fixationJapanese Journal of Ophthalmology, 2018
- Flanged Intrascleral Intraocular Lens Fixation with Double-Needle TechniqueOphthalmology, 2017
- Sutureless 27-gauge needle-assisted transconjunctival intrascleral intraocular lens fixation: Initial experienceIndian Journal Of Ophthalmology, 2017
- Sutureless 27-Gauge Needle–Guided Intrascleral Intraocular Lens Implantation with Lamellar Scleral DissectionOphthalmology, 2014
- Four-point scleral fixation of posterior chamber intraocular lenses without scleral flapsBritish Journal of Ophthalmology, 2010