Tamer Gamal Elsayed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tamer Gamal Elsayed has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Adel Farag
Ophthalmology department, Faculty of medicine, Zagazig University, Sharkia, Egypt
1 shared publication- Ahmed Samir
Department of Ophthalmology, Faculty of Medicine, Zagazig University, Zagazig, Sharkia, Egypt
1 shared publication - Ayman Lotfy
Assistant Professor of Ophthalmology, Ophthalmology Department, Zagazig University, Zagazig, Egypt
1 shared publication - Ayman M Abdelrahman Elsayed
Department of Ophthalmology, Zagazig University, Zagazig, Sharkia, Egypt
1 shared publication Basem Mohamed Ibrahim
Ophthalmology department, Faculty of medicine, Zagazig University, Sharkia, Egypt
1 shared publicationEmad Mohamed Elhady
Ophthalmology, Faculty of Medicine, Zagazig University, Egypt
1 shared publication
Latest Publications
- 2 October 2021
- Published by Egyptian Knowledge Bank in Zagazig University Medical Journal
Flanged Scleral Fixated Intraocular Lens for Correction of Aphakia in Zagazig University Hospitals
Background: Intraocular lens (IOL) implantation in the absence of capsular support represents a surgical challenge. Several techniques have been used for IOL implantation in aphakic eyes without adequate capsular support. The aim of this study was to compare the efficiency and visual results of Yamane technique with the glued IOL technique in correction of aphakia without adequate capsular support in Zagazig University Hospitals. Methods: Forty-Eight Aphakic eyes of 48 patients without adequate capsular support were included in this study. All eyes were planned to be corrected with posterior chamber foldable IOL implantation using either Yamane flanged scleral fixated IOL technique- (Group A)- or glued scleral fixated IOL technique- (Group B), 24 aphakic eyes were enrolled randomly in each group. Pre-operative, intra-operative and post-operative data including uncorrected and best corrected visual acuity, intraocular pressure, and endothelial cell count were recorded. Surgical time, intra-operative difficulties and post-operative complications were recorded. Patients were followed up for 6 months at least.Results: Forty-eight aphakic eyes without adequate capsular support following complicated phacoemulsification were enrolled randomly in tow groups (A&B). In all cases a three-piece foldable hydrophobic IOLs were used. There is clear statistically significant difference between pre- and post-UCVA (p < 0.001) in both groups. Complications included captured IOL in one case in group A, IOL decentration in 2 cases in group A and 3 cases in group B. Conclusion: Flanged intrascleral fixation of three-piece IOLs (Yamane technique) and glued scleral fixated IOLs, both are safe efficient methods for correction of aphakia.
- 2 October 2021
- Published by Egyptian Knowledge Bank in Zagazig University Medical Journal
Flanged Scleral Fixated Intraocular Lens for Correction of Aphakia in Zagazig University Hospitals
Background: Intraocular lens (IOL) implantation in the absence of capsular support represents a surgical challenge. Several techniques have been used for IOL implantation in aphakic eyes without adequate capsular support. The aim of this study was to compare the efficiency and visual results of Yamane technique with the glued IOL technique in correction of aphakia without adequate capsular support in Zagazig University Hospitals. Methods: Forty-Eight Aphakic eyes of 48 patients without adequate capsular support were included in this study. All eyes were planned to be corrected with posterior chamber foldable IOL implantation using either Yamane flanged scleral fixated IOL technique- (Group A)- or glued scleral fixated IOL technique- (Group B), 24 aphakic eyes were enrolled randomly in each group. Pre-operative, intra-operative and post-operative data including uncorrected and best corrected visual acuity, intraocular pressure, and endothelial cell count were recorded. Surgical time, intra-operative difficulties and post-operative complications were recorded. Patients were followed up for 6 months at least.Results: Forty-eight aphakic eyes without adequate capsular support following complicated phacoemulsification were enrolled randomly in tow groups (A&B). In all cases a three-piece foldable hydrophobic IOLs were used. There is clear statistically significant difference between pre- and post-UCVA (p < 0.001) in both groups. Complications included captured IOL in one case in group A, IOL decentration in 2 cases in group A and 3 cases in group B. Conclusion: Flanged intrascleral fixation of three-piece IOLs (Yamane technique) and glued scleral fixated IOLs, both are safe efficient methods for correction of aphakia.
- Open Access
- 1 July 2021
- Published by Egyptian Knowledge Bank in The Egyptian Journal of Hospital Medicine
- Vol. 84 (1) , 2538-2541
Evaluation of Lacrimal Sac Diameter in Different Age groups Using Ultrasound Biomicroscopy
Background: Chronic dacryocystitis is the most frequent disorder in the lacrimal drainage system. The disease has been considered to be strongly associated with obstruction of the lacrimal duct, which creates a fertile environment for bacterial colonization and promotes lacrimal sac inflammation. Objective: The aim of this work was to evaluate lacrimal sac diameter in different age groups using ultrasound biomicroscopy (UBM). Patients and Methods: Twenty-four eyes of 24 normal individuals. They were divided according to age into 3 groups; group A: age ranging between 30 and 40 years, group B: age ranging between 40 and 50 years and group C: age above 50 years. Lacrimal sac diameter was assessed. Ocular examination and special tests were done for lacrimal drainage system (regurge test and fluorescein dye disappearance test) with imaging of lacrimal passages by ultrasound biomicroscopy. Results: All patients had no symptoms of epiphora, negative both regurge test and dye disappearance test and clear contents of the lacrimal sac. There was no statistically significant difference between groups regarding either longitudinal or horizontal lacrimal sac diameter. Conclusion: UBM can be used for imaging and measuring lacrimal passages and thus can be useful as an adjunctive to clinical examination and surgical planning in cases with lacrimal system diseases.
- 1 July 2021
- Published by Egyptian Knowledge Bank in The Egyptian Journal of Hospital Medicine
- Vol. 84 (1) , 2538-2541
Open AccessEvaluation of Lacrimal Sac Diameter in Different Age groups Using Ultrasound Biomicroscopy
Background: Chronic dacryocystitis is the most frequent disorder in the lacrimal drainage system. The disease has been considered to be strongly associated with obstruction of the lacrimal duct, which creates a fertile environment for bacterial colonization and promotes lacrimal sac inflammation. Objective: The aim of this work was to evaluate lacrimal sac diameter in different age groups using ultrasound biomicroscopy (UBM). Patients and Methods: Twenty-four eyes of 24 normal individuals. They were divided according to age into 3 groups; group A: age ranging between 30 and 40 years, group B: age ranging between 40 and 50 years and group C: age above 50 years. Lacrimal sac diameter was assessed. Ocular examination and special tests were done for lacrimal drainage system (regurge test and fluorescein dye disappearance test) with imaging of lacrimal passages by ultrasound biomicroscopy. Results: All patients had no symptoms of epiphora, negative both regurge test and dye disappearance test and clear contents of the lacrimal sac. There was no statistically significant difference between groups regarding either longitudinal or horizontal lacrimal sac diameter. Conclusion: UBM can be used for imaging and measuring lacrimal passages and thus can be useful as an adjunctive to clinical examination and surgical planning in cases with lacrimal system diseases.
- Open Access
- 1 October 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 3131-3136
Scleral Fixation of Single-Piece Foldable IOL Using Double-Flanged Technique
Purpose: To describe the efficiency and visual results of a new method of transconjunctival intrascleral fixation of single-piece foldable IOL using double-flanged 6/0 prolene suture. Materials and Methods: Seventeen aphakic eyes of 17 patients without adequate capsular support were involved in this study. Lens was prepared by passing the 6/0 prolene suture in a track in the haptic of single-piece foldable IOL created by 31 g needle. The 6/0 prolene suture was retrieved through a 30 g needle transconjunctivally to outside the globe; then, IOL was implanted and a terminal bulb was created at the outer end of the prolene suture. Results: All cases were aphakic after complicated phacoemulsification. In 10 cases hydrophilic IOLs were used and in 7 cases hydrophobic IOLs were used. There is clear statistically significant difference between pre-UCVA and post- UCVA. Complications included suture slippage in 2 cases and prolene bulb exposure in one case. There was no significant difference in endothelial cell count and IOP before and after 3 months. Conclusion: Transconjunctival intrascleral fixation of foldable single-piece IOLs is a safe efficient method for correcting aphakia.
- 1 October 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 3131-3136
Open AccessScleral Fixation of Single-Piece Foldable IOL Using Double-Flanged Technique
Purpose: To describe the efficiency and visual results of a new method of transconjunctival intrascleral fixation of single-piece foldable IOL using double-flanged 6/0 prolene suture. Materials and Methods: Seventeen aphakic eyes of 17 patients without adequate capsular support were involved in this study. Lens was prepared by passing the 6/0 prolene suture in a track in the haptic of single-piece foldable IOL created by 31 g needle. The 6/0 prolene suture was retrieved through a 30 g needle transconjunctivally to outside the globe; then, IOL was implanted and a terminal bulb was created at the outer end of the prolene suture. Results: All cases were aphakic after complicated phacoemulsification. In 10 cases hydrophilic IOLs were used and in 7 cases hydrophobic IOLs were used. There is clear statistically significant difference between pre-UCVA and post- UCVA. Complications included suture slippage in 2 cases and prolene bulb exposure in one case. There was no significant difference in endothelial cell count and IOP before and after 3 months. Conclusion: Transconjunctival intrascleral fixation of foldable single-piece IOLs is a safe efficient method for correcting aphakia.