Influence of elevated temperature on buckling capacity of mild steel-based cold-formed steel column sections– experimental investigation and finite element modelling
- 10 November 2023
- journal article
- research article
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 15 (3) , 314-337
Abstract
Purpose: The capability of steel columns to support their design loads is highly affected by the time of exposure and temperature magnitude, which causes deterioration of mechanical properties of steel under fire conditions. It is known that structural steel loses strength and stiffness as temperature increases, particularly above 400 °C. The duration of time in which steel is exposed to high temperatures also has an impact on how much strength it loses. The time-dependent response of steel is critical when estimating load carrying capacity of steel columns exposed to fire. Thus, investigating the structural response of cold-formed steel (CFS) columns is gaining more interest due to the nature of such structural elements.Design/methodology/approach: In this study, experiments were conducted on two CFS configurations: back-to-back (B-B) channel and toe-to-toe (T-T) channel sections. All CFS column specimens were exposed to different temperatures following the standard fire curve and cooled by air or water. A total of 14 tests were conducted to evaluate the capacity of the CFS sections. The axial resistance and yield deformation were noted for both section types at elevated temperatures. The CFS column sections were modelled to simulate the section's behaviour under various temperature exposures using the general-purpose finite element (FE) program ABAQUS. The results from FE modelling agreed well with the experimental results. Ultimate load of experiment and finite element model (FEM) are compared with each other. The difference in percentage and ratio between both are presented.Findings: The results showed that B-B configuration showed better performance for all the investigated parameters than T-T sections. A noticeable loss in the ultimate strength of 34.5 and 65.6% was observed at 90 min (986℃) for B-B specimens cooled using air and water, respectively. However, the reduction was 29.9 and 46% in the T-T configuration, respectively.Originality/value: This research paper focusses on assessing the buckling strength of heated CFS sections to analyse the mode of failure of CFS sections with B-B and T-T design configurations under the effect of elevated temperature.Keywords
This publication has 28 references indexed in Scilit:
- Design of cold-formed high strength steel tubular beamsEngineering Structures, 2017
- Seismic behavior of steel sheathed cold-formed steel shear wall: Experimental investigation and numerical modelingThin-Walled Structures, 2015
- Cold-formed steel columns made with open cross-sections subjected to fireThin-Walled Structures, 2014
- Experimental and numerical studies of fire exposed lipped channel columns subject to distortional bucklingFire Safety Journal, 2014
- Ultimate load-carrying capacity of cold-formed thin-walled columns with built-up box and I section under axial compressionThin-Walled Structures, 2014
- Cold-formed steel sections with web openings subjected to web crippling under two-flange loading conditions—Part II: Parametric study and proposed design equationsThin-Walled Structures, 2012
- Compression tests of cold-formed steel I-shaped open sections with edge and web stiffenersThin-Walled Structures, 2012
- An experimental study of loaded full-scale cold-formed thin-walled steel structural panels under fire conditionsFire Safety Journal, 2005
- An analysis of the structural behaviour of axially loaded full-scale cold-formed thin-walled steel structural panels tested under fire conditionsThin-Walled Structures, 2005
- Axial strength of cold-formed thin-walled steel channels under non-uniform temperatures in fireFire Safety Journal, 2003