Varun Sabu Sam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Varun Sabu Sam has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Nammalvar Anand
Department of Civil Engineering, Karunya Institute of Technology and Sciences, Coimbatore 641114, India
10 shared publications - A. Diana Andrushia
Department of Electronics and Communication Engineering, Karunya Institute of Technology and Sciences, Coimbatore 641114, India
3 shared publications - Beulah Gnana Ananthi Gurupatham
Department of Civil Engineering, College of Engineering Guindy Campus, Anna University, Chennai 600025, India
3 shared publications Diana Andrushia
Department of ECE, Karunya Institute of Technology and Sciences, Coimbatore, India
3 shared publications- Krishanu Roy
School of Engineering, Civil Engineering, The University of Waikato, Hamilton 3216, New Zealand
3 shared publications Garry Robson Lyngdoh
2 shared publications
Latest Publications
- 17 February 2026
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Forensic Engineering
- Vol. 179 (3) , 1-14
Impact of protective coatings on fire resistance and axial capacity of galvanised CFS columns
The literature on the structural performance of cold-formed steel (CFS) columns under fire conditions is limited. This study delivers critical insights into the buckling behaviour of back-to-back connected CFS columns with three different fire-resistant coatings. These columns underwent various heating and cooling procedures. Outcomes of this research offer significant implications for building codes and standards, particularly in understanding the effects of thermal exposure and cooling methods on CFS structural elements. In all specimens, the failure pattern observed was consistent, characterised primarily by significant buckling. Notably, sections coated with perlite demonstrated superior performance in fire resistance compared with other sections that were coated and heated. Among the coated specimens heated to 60 min and cooled using air, BC2AC (perlite) has the highest ultimate load at 268.93 kN, which is just 1.7% lower than the unheated section and 7.2% higher than BC1AC (gypsum) and 12.6% higher than BC3AC (vermiculite). This study contributes essential observations into the axial resistance of columns with various coatings under varying temperature and cooling conditions, potentially informing updates to standard guidelines regarding the impact of heating and cooling.
- 17 February 2026
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Forensic Engineering
- Vol. 179 (3) , 1-14
Impact of protective coatings on fire resistance and axial capacity of galvanised CFS columns
The literature on the structural performance of cold-formed steel (CFS) columns under fire conditions is limited. This study delivers critical insights into the buckling behaviour of back-to-back connected CFS columns with three different fire-resistant coatings. These columns underwent various heating and cooling procedures. Outcomes of this research offer significant implications for building codes and standards, particularly in understanding the effects of thermal exposure and cooling methods on CFS structural elements. In all specimens, the failure pattern observed was consistent, characterised primarily by significant buckling. Notably, sections coated with perlite demonstrated superior performance in fire resistance compared with other sections that were coated and heated. Among the coated specimens heated to 60 min and cooled using air, BC2AC (perlite) has the highest ultimate load at 268.93 kN, which is just 1.7% lower than the unheated section and 7.2% higher than BC1AC (gypsum) and 12.6% higher than BC3AC (vermiculite). This study contributes essential observations into the axial resistance of columns with various coatings under varying temperature and cooling conditions, potentially informing updates to standard guidelines regarding the impact of heating and cooling.
- 25 November 2025
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 17 (2) , 153-184
Influence of stiffener configurations on the post-fire flexural capacity of mild steel based cold-formed steel beams
Purpose: Because of its many benefits over conventional steel kinds, cold-formed steel (CFS) members – which are reputed by their thin profiles – are becoming more common in the building industry. The performance of CFS composed of mild steel (MS) under very high temperatures, especially about its flexural behavior, has, however, received comparatively little attention. Design/methodology/approach: The flexural behavior of CFS beams made of MS under high temperature and after being cooled down to room temperature with both air and water is carefully examined in this work. A detailed analysis is conducted of the effects of temperature loading and the efficiency of the two cooling methods. The direct strength method (DSM) and ABAQUS finite element (FE) modeling findings are compared and evaluated with the experimental data. Additionally, a parametric analysis is conducted on the beams to assess the effects of not providing a stiffener versus using a horizontal stiffener. Findings: Among the experimental sections, the maximum load was observed for the reference specimen at 90.26 kN. The specimen that was heated for 90 min and cooled with water had the least reported load, which was 35.5 kN. For the beam that was heated for 60 min then cooled with water, there is a noticeable drop in load. The load capacity of the sections that were heated for 60 min and cooled with air and water differed by 41.9%. Interestingly, specimens that were heated for 90 min showed a notable reduction in stiffness. Sections that have been heated for 90 min exhibit an abrupt reduction in stiffness. Additionally, the stiffness of sections heated for 60 and 90 min and cooled with air differs by 100%. The mode of failure for beam sections with vertical and horizontal stiffeners was distortional buckling (DB), with some instances of local buckling observed in members with vertical stiffeners. Conversely, beam sections without any stiffener experienced lateral torsional buckling as the dominant failure mode. Compared to the reference section, the loads obtained through parametric analysis were lower by 45–85% for horizontally stiffened beams and by 68.5–123.5% for beams without stiffeners. The maximum load reduction of nearly 60% was recorded for beams exposed to 90 min of heating followed by water cooling. These quantified effects provide clear insights into the role of heating duration, cooling method and stiffener configuration on post-fire flexural behavior. Originality/value: This study provides a comprehensive evaluation of the post-fire flexural behavior of CFS beams made of MS, including the effects of both air- and water-cooling methods. Unlike traditional fire performance studies, this work examines residual strength characteristics after cooling, reflecting real-world post-fire assessment needs. The paper also contributes new insights into the influence of stiffener configuration on failure modes under elevated temperature exposure.
- 25 November 2025
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 17 (2) , 153-184
Influence of stiffener configurations on the post-fire flexural capacity of mild steel based cold-formed steel beams
Purpose: Because of its many benefits over conventional steel kinds, cold-formed steel (CFS) members – which are reputed by their thin profiles – are becoming more common in the building industry. The performance of CFS composed of mild steel (MS) under very high temperatures, especially about its flexural behavior, has, however, received comparatively little attention. Design/methodology/approach: The flexural behavior of CFS beams made of MS under high temperature and after being cooled down to room temperature with both air and water is carefully examined in this work. A detailed analysis is conducted of the effects of temperature loading and the efficiency of the two cooling methods. The direct strength method (DSM) and ABAQUS finite element (FE) modeling findings are compared and evaluated with the experimental data. Additionally, a parametric analysis is conducted on the beams to assess the effects of not providing a stiffener versus using a horizontal stiffener. Findings: Among the experimental sections, the maximum load was observed for the reference specimen at 90.26 kN. The specimen that was heated for 90 min and cooled with water had the least reported load, which was 35.5 kN. For the beam that was heated for 60 min then cooled with water, there is a noticeable drop in load. The load capacity of the sections that were heated for 60 min and cooled with air and water differed by 41.9%. Interestingly, specimens that were heated for 90 min showed a notable reduction in stiffness. Sections that have been heated for 90 min exhibit an abrupt reduction in stiffness. Additionally, the stiffness of sections heated for 60 and 90 min and cooled with air differs by 100%. The mode of failure for beam sections with vertical and horizontal stiffeners was distortional buckling (DB), with some instances of local buckling observed in members with vertical stiffeners. Conversely, beam sections without any stiffener experienced lateral torsional buckling as the dominant failure mode. Compared to the reference section, the loads obtained through parametric analysis were lower by 45–85% for horizontally stiffened beams and by 68.5–123.5% for beams without stiffeners. The maximum load reduction of nearly 60% was recorded for beams exposed to 90 min of heating followed by water cooling. These quantified effects provide clear insights into the role of heating duration, cooling method and stiffener configuration on post-fire flexural behavior. Originality/value: This study provides a comprehensive evaluation of the post-fire flexural behavior of CFS beams made of MS, including the effects of both air- and water-cooling methods. Unlike traditional fire performance studies, this work examines residual strength characteristics after cooling, reflecting real-world post-fire assessment needs. The paper also contributes new insights into the influence of stiffener configuration on failure modes under elevated temperature exposure.
- 30 March 2025
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 10 (4) , 1-17
Web crippling strength of GI based cold- formed steel under high temperature: experimental and analytical modeling
- 30 March 2025
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 10 (4) , 1-17
Web crippling strength of GI based cold- formed steel under high temperature: experimental and analytical modeling
- Open Access
Effect of Protective Coatings on Post-Fire Performance and Behavior of Mild Steel-Based Cold-Formed Steel Back-to-Back Channel Columns with Bolted Connections
This study investigates the buckling performance of built-up cold-formed steel (CFS) columns, with a focus on how different thermal exposures and cooling strategies influence their susceptibility to various failure mechanisms. Addressing the gap in the literature on the fire behavior of mild steel (MS)-based CFS columns, the research aims to provide new insights. Compression tests were conducted on MS-based CFS column specimens after they were exposed to fire, to assess their post-fire buckling strength. The columns were subjected to controlled fire conditions following standardized protocols and then allowed to cool to room temperature. The study examined axial load-bearing capacity and deformation characteristics under elevated temperatures. To improve fire resistance, protective coatings—gypsum, perlite, and vermiculite—were applied to certain specimens before testing, and their performance was compared to that of uncoated specimens. A comprehensive finite element analysis (FEA) was also performed to model the structural response under different thermal and cooling scenarios, providing a detailed comparison of the coating effectiveness, which was validated against experimental results. The findings revealed significant variations in axial strength and failure mechanisms based on the type of fire-resistant coating used, as well as the heating and cooling durations. Among the coated specimens, those treated with perlite showed the best performance. For example, the air-cooled perlite-coated column (MBC2AC) retained a load capacity of 277.9 kN after 60 min of heating, a reduction of only 6.0% compared to the unheated reference section (MBREF). This performance was superior to that of the gypsum-coated (MBC1AC) and vermiculite-coated (MBC3AC) specimens, which showed reductions of 3.6% and 7.9% more, respectively. These results highlight the potential of perlite coatings to enhance the fire resistance of CFS columns, offering valuable insights for structural fire design.
Open AccessEffect of Protective Coatings on Post-Fire Performance and Behavior of Mild Steel-Based Cold-Formed Steel Back-to-Back Channel Columns with Bolted Connections
This study investigates the buckling performance of built-up cold-formed steel (CFS) columns, with a focus on how different thermal exposures and cooling strategies influence their susceptibility to various failure mechanisms. Addressing the gap in the literature on the fire behavior of mild steel (MS)-based CFS columns, the research aims to provide new insights. Compression tests were conducted on MS-based CFS column specimens after they were exposed to fire, to assess their post-fire buckling strength. The columns were subjected to controlled fire conditions following standardized protocols and then allowed to cool to room temperature. The study examined axial load-bearing capacity and deformation characteristics under elevated temperatures. To improve fire resistance, protective coatings—gypsum, perlite, and vermiculite—were applied to certain specimens before testing, and their performance was compared to that of uncoated specimens. A comprehensive finite element analysis (FEA) was also performed to model the structural response under different thermal and cooling scenarios, providing a detailed comparison of the coating effectiveness, which was validated against experimental results. The findings revealed significant variations in axial strength and failure mechanisms based on the type of fire-resistant coating used, as well as the heating and cooling durations. Among the coated specimens, those treated with perlite showed the best performance. For example, the air-cooled perlite-coated column (MBC2AC) retained a load capacity of 277.9 kN after 60 min of heating, a reduction of only 6.0% compared to the unheated reference section (MBREF). This performance was superior to that of the gypsum-coated (MBC1AC) and vermiculite-coated (MBC3AC) specimens, which showed reductions of 3.6% and 7.9% more, respectively. These results highlight the potential of perlite coatings to enhance the fire resistance of CFS columns, offering valuable insights for structural fire design.
- 24 September 2024
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 9 (10) , 1-23
Flexural behavior of cold-formed mild steel beams with web holes exposed to high temperature: analytical and experimental investigation
- 24 September 2024
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 9 (10) , 1-23
Flexural behavior of cold-formed mild steel beams with web holes exposed to high temperature: analytical and experimental investigation
- Open Access
Investigation on Flexural Behavior of Galvanized Cold-Formed Steel Beams Exposed to Fire with Different Stiffener Configurations
Cold-formed steel (CFS) sections, increasingly favored in the construction industry due to their numerous advantages over hot-rolled steel, have received limited attention in research concerning the flexural behavior of galvanized iron (GI)-based CFS at elevated temperatures. Understanding how these materials and structures behave under elevated temperatures is crucial for fire safety. The authors have performed experimental studies previously on GI-based CFS under elevated temperatures. In that study, CFS sections made of GI of grade E350 of 1.5 m long and 2 mm thickness were used. Built-up beam sections were tested under two-point loading after heating to 60 and 90 min durations and subsequently cooling them down using air and water. This study aims to uncover the influence of different stiffener configurations on the load carrying capacity of sections under elevated temperature parametrically. With the experimental study results from previous studies as a reference, authors used FEM analysis to comprehensively study the behavior of GI-based CFS sections under fire. Vertical, horizontal, and not providing a stiffener were the configurations selected to study the beams parametrically. Parametric analysis confirmed that different stiffener configurations did not alter the predominant failure mode, which remained distortional buckling across all specimens. Beams with vertical stiffeners demonstrated superior performance compared to those with horizontal stiffeners in parametric analysis. Lateral–torsional buckling was observed in the reference specimen, lacking stiffeners due to inadequate restraint at the supports.
Open AccessInvestigation on Flexural Behavior of Galvanized Cold-Formed Steel Beams Exposed to Fire with Different Stiffener Configurations
Cold-formed steel (CFS) sections, increasingly favored in the construction industry due to their numerous advantages over hot-rolled steel, have received limited attention in research concerning the flexural behavior of galvanized iron (GI)-based CFS at elevated temperatures. Understanding how these materials and structures behave under elevated temperatures is crucial for fire safety. The authors have performed experimental studies previously on GI-based CFS under elevated temperatures. In that study, CFS sections made of GI of grade E350 of 1.5 m long and 2 mm thickness were used. Built-up beam sections were tested under two-point loading after heating to 60 and 90 min durations and subsequently cooling them down using air and water. This study aims to uncover the influence of different stiffener configurations on the load carrying capacity of sections under elevated temperature parametrically. With the experimental study results from previous studies as a reference, authors used FEM analysis to comprehensively study the behavior of GI-based CFS sections under fire. Vertical, horizontal, and not providing a stiffener were the configurations selected to study the beams parametrically. Parametric analysis confirmed that different stiffener configurations did not alter the predominant failure mode, which remained distortional buckling across all specimens. Beams with vertical stiffeners demonstrated superior performance compared to those with horizontal stiffeners in parametric analysis. Lateral–torsional buckling was observed in the reference specimen, lacking stiffeners due to inadequate restraint at the supports.
- Open Access
Flexural Behavior of Galvanized Iron Based Cold-Formed Steel Back-to-Back Built-Up Beams at Elevated Temperatures
Cold-formed steel (CFS) sections have become popular in construction due to several advantages over structural steel. However, research on the performance of galvanized iron (GI)-based CFS under high temperatures, especially regarding its flexural behavior, has been limited. This study extensively investigates how GI-based CFS beams with varying spans behave under elevated temperatures and subsequent cooling using air and water. This study examines the impact of temperature loading and compares the effectiveness of air- and water-cooling methods. Experimental results are validated and analyzed alongside findings from finite element modeling (FEM) using ABAQUS (2019_09_13-23.19.31) and the Direct Strength Method (DSM). Additionally, this study conducts a parametric investigation to assess how beam span influences flexural capacity. Among beams heated to the same temperature, those cooled with water show slightly lower load capacities compared to those cooled with air. The highest load capacity observed is 64.3 kN for the reference specimen, while the lowest is 26.2 kN for the specimen heated for 90 min and cooled with water, a 59.27% difference between them. Stiffness decreases as heating duration increases, with the reference section exhibiting significantly higher stiffness compared to the section heated for 90 min and cooled with water, with a 92.76% difference in stiffness. As heating duration increases, ductility also increases. Various failure modes are observed based on different heating and cooling conditions across different beam spans. This study provides insights into how GI-based CFS beams perform under temperature stress and different cooling scenarios, contributing valuable data for structural design and safety considerations in construction.
Open AccessFlexural Behavior of Galvanized Iron Based Cold-Formed Steel Back-to-Back Built-Up Beams at Elevated Temperatures
Cold-formed steel (CFS) sections have become popular in construction due to several advantages over structural steel. However, research on the performance of galvanized iron (GI)-based CFS under high temperatures, especially regarding its flexural behavior, has been limited. This study extensively investigates how GI-based CFS beams with varying spans behave under elevated temperatures and subsequent cooling using air and water. This study examines the impact of temperature loading and compares the effectiveness of air- and water-cooling methods. Experimental results are validated and analyzed alongside findings from finite element modeling (FEM) using ABAQUS (2019_09_13-23.19.31) and the Direct Strength Method (DSM). Additionally, this study conducts a parametric investigation to assess how beam span influences flexural capacity. Among beams heated to the same temperature, those cooled with water show slightly lower load capacities compared to those cooled with air. The highest load capacity observed is 64.3 kN for the reference specimen, while the lowest is 26.2 kN for the specimen heated for 90 min and cooled with water, a 59.27% difference between them. Stiffness decreases as heating duration increases, with the reference section exhibiting significantly higher stiffness compared to the section heated for 90 min and cooled with water, with a 92.76% difference in stiffness. As heating duration increases, ductility also increases. Various failure modes are observed based on different heating and cooling conditions across different beam spans. This study provides insights into how GI-based CFS beams perform under temperature stress and different cooling scenarios, contributing valuable data for structural design and safety considerations in construction.
- 8 July 2024
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 16 (1) , 1-36
Influence of section profiles on flexural behavior of unsymmetrical cold formed steel sections – analytical and numerical investigation
Purpose: Cold-formed steel (CFS) sections are a popular choice for constructing medium and low-rise structures that are engineered to support relatively light loads. An important characteristic of CFS sections is that they are produced without the use of heat during manufacturing. Consequently, it becomes essential to gain a comprehensive understanding in the behavior of CFS sections when exposed to fire or elevated temperatures.Design/methodology/approach: In this study, sections of 1.5 m length and 2 mm thickness were taken and analyzed to find its flexural behavior after heating them for 60 and 90 min. There were two modes of cooling phase which was considered to reach ambient temperature, i.e. air or water respectively. Performance of each sections (C, C with inclined flanges, sigma and Zed) were examined and evaluated at different conditions. Effects of different profiles and lips in the profiles on flexural behavior of CFS sections were investigated fully analytically.Findings: The variation in stiffness among the sections with different lipped profiles was noted between 20.36 and 33.26%, for 60 min water cooling case. For the sections with unlipped profiles, it was between 23.56 and 28.60%. Influence of lip and section profile on reduction in stiffness is marginal. The average reduction in load capacity of sections for 60 min specimens cooled by water was found to be 43.42%. An increase in deflection is observed for the sections in the range of 25–37.23% for 60 min case. This is the critical temperature responsible for reduction in yield strength of material as it substantially increases the material safety margin to be considered for the design. Sections with Zed profile have shown better performance among other types, in terms of its load carrying capacity.Originality/value: This paper deals with the flexural behavior of Galvanized (GI) based CFS unsymmetric sections at elevated temperature and cooled down to ambient temperature with air or water.
- 8 July 2024
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 16 (1) , 1-36
Influence of section profiles on flexural behavior of unsymmetrical cold formed steel sections – analytical and numerical investigation
Purpose: Cold-formed steel (CFS) sections are a popular choice for constructing medium and low-rise structures that are engineered to support relatively light loads. An important characteristic of CFS sections is that they are produced without the use of heat during manufacturing. Consequently, it becomes essential to gain a comprehensive understanding in the behavior of CFS sections when exposed to fire or elevated temperatures.Design/methodology/approach: In this study, sections of 1.5 m length and 2 mm thickness were taken and analyzed to find its flexural behavior after heating them for 60 and 90 min. There were two modes of cooling phase which was considered to reach ambient temperature, i.e. air or water respectively. Performance of each sections (C, C with inclined flanges, sigma and Zed) were examined and evaluated at different conditions. Effects of different profiles and lips in the profiles on flexural behavior of CFS sections were investigated fully analytically.Findings: The variation in stiffness among the sections with different lipped profiles was noted between 20.36 and 33.26%, for 60 min water cooling case. For the sections with unlipped profiles, it was between 23.56 and 28.60%. Influence of lip and section profile on reduction in stiffness is marginal. The average reduction in load capacity of sections for 60 min specimens cooled by water was found to be 43.42%. An increase in deflection is observed for the sections in the range of 25–37.23% for 60 min case. This is the critical temperature responsible for reduction in yield strength of material as it substantially increases the material safety margin to be considered for the design. Sections with Zed profile have shown better performance among other types, in terms of its load carrying capacity.Originality/value: This paper deals with the flexural behavior of Galvanized (GI) based CFS unsymmetric sections at elevated temperature and cooled down to ambient temperature with air or water.
- Open Access
- 31 March 2024
- Published by EJSE International in Electronic Journal of Structural Engineering
- Vol. 24 (1) , 53-59
Investigation on Residual Mechanical Properties of Galvanized Iron Cold-Formed Steel Sections Exposed to Elevated Temperatures
Cold-formed steel (CFS) sections are used to construct medium and low-rise structures designed to carry small-scale loads. CFS sections are manufactured without the application of heat. Therefore, it is crucial to comprehend the properties of CFS sections which are exposed to fire or elevated temperatures. To simulate the real- time fire exposure, an ISO Standard fire curve was used to heat the CFS sections. The objective of the study is to assess the residual mechanical strength of exposed sections after the elevated temperature test. The study aims to compile data for forecasting the degeneration of elements and to ascertain whether the structural components can be reused or replaced. The CFS sections were subjected to different temperatures, and after heating, two cooling methods were used to bring down to room temperature. The characteristics of the retrieved specimens, taken from exposed CFS sections were assessed using a tensile coupon test. The residual properties such as ultimate strength, yield strength, and elastic modulus were examined and reported. The influence of heating and cooling is more pronounced from the test results. A reduction in the yield and ultimate strength was noticed, and it was found to decrease as the heating intensity increases for air and water cooling respectively. In the case of yield and ultimate strength, the strength reduction is critical beyond 60 minutes. The elastic modulus was also found to be reducing with a similar trend. Based on the test results, reduction factors are proposed for ultimate strength, yield strength and elastic modulus. Reduction factors obtained for yield strength under 60 minutes of heating for air and water cooling is 0.575 and 0.557 respectively. In 120 minutes, the values are 0.400 and 0.329. Reduction factors obtained for ultimate strength under 60 minutes of heating for air and water cooling is 0.586 and 0.566 respectively. For 120 minutes, the values are 0.331 and 0.313.
- 31 March 2024
- Published by EJSE International in Electronic Journal of Structural Engineering
- Vol. 24 (1) , 53-59
Open AccessInvestigation on Residual Mechanical Properties of Galvanized Iron Cold-Formed Steel Sections Exposed to Elevated Temperatures
Cold-formed steel (CFS) sections are used to construct medium and low-rise structures designed to carry small-scale loads. CFS sections are manufactured without the application of heat. Therefore, it is crucial to comprehend the properties of CFS sections which are exposed to fire or elevated temperatures. To simulate the real- time fire exposure, an ISO Standard fire curve was used to heat the CFS sections. The objective of the study is to assess the residual mechanical strength of exposed sections after the elevated temperature test. The study aims to compile data for forecasting the degeneration of elements and to ascertain whether the structural components can be reused or replaced. The CFS sections were subjected to different temperatures, and after heating, two cooling methods were used to bring down to room temperature. The characteristics of the retrieved specimens, taken from exposed CFS sections were assessed using a tensile coupon test. The residual properties such as ultimate strength, yield strength, and elastic modulus were examined and reported. The influence of heating and cooling is more pronounced from the test results. A reduction in the yield and ultimate strength was noticed, and it was found to decrease as the heating intensity increases for air and water cooling respectively. In the case of yield and ultimate strength, the strength reduction is critical beyond 60 minutes. The elastic modulus was also found to be reducing with a similar trend. Based on the test results, reduction factors are proposed for ultimate strength, yield strength and elastic modulus. Reduction factors obtained for yield strength under 60 minutes of heating for air and water cooling is 0.575 and 0.557 respectively. In 120 minutes, the values are 0.400 and 0.329. Reduction factors obtained for ultimate strength under 60 minutes of heating for air and water cooling is 0.586 and 0.566 respectively. For 120 minutes, the values are 0.331 and 0.313.
- 10 November 2023
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 15 (3) , 314-337
Influence of elevated temperature on buckling capacity of mild steel-based cold-formed steel column sections– experimental investigation and finite element modelling
Purpose: The capability of steel columns to support their design loads is highly affected by the time of exposure and temperature magnitude, which causes deterioration of mechanical properties of steel under fire conditions. It is known that structural steel loses strength and stiffness as temperature increases, particularly above 400 °C. The duration of time in which steel is exposed to high temperatures also has an impact on how much strength it loses. The time-dependent response of steel is critical when estimating load carrying capacity of steel columns exposed to fire. Thus, investigating the structural response of cold-formed steel (CFS) columns is gaining more interest due to the nature of such structural elements.Design/methodology/approach: In this study, experiments were conducted on two CFS configurations: back-to-back (B-B) channel and toe-to-toe (T-T) channel sections. All CFS column specimens were exposed to different temperatures following the standard fire curve and cooled by air or water. A total of 14 tests were conducted to evaluate the capacity of the CFS sections. The axial resistance and yield deformation were noted for both section types at elevated temperatures. The CFS column sections were modelled to simulate the section's behaviour under various temperature exposures using the general-purpose finite element (FE) program ABAQUS. The results from FE modelling agreed well with the experimental results. Ultimate load of experiment and finite element model (FEM) are compared with each other. The difference in percentage and ratio between both are presented.Findings: The results showed that B-B configuration showed better performance for all the investigated parameters than T-T sections. A noticeable loss in the ultimate strength of 34.5 and 65.6% was observed at 90 min (986℃) for B-B specimens cooled using air and water, respectively. However, the reduction was 29.9 and 46% in the T-T configuration, respectively.Originality/value: This research paper focusses on assessing the buckling strength of heated CFS sections to analyse the mode of failure of CFS sections with B-B and T-T design configurations under the effect of elevated temperature.
- 10 November 2023
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 15 (3) , 314-337
Influence of elevated temperature on buckling capacity of mild steel-based cold-formed steel column sections– experimental investigation and finite element modelling
Purpose: The capability of steel columns to support their design loads is highly affected by the time of exposure and temperature magnitude, which causes deterioration of mechanical properties of steel under fire conditions. It is known that structural steel loses strength and stiffness as temperature increases, particularly above 400 °C. The duration of time in which steel is exposed to high temperatures also has an impact on how much strength it loses. The time-dependent response of steel is critical when estimating load carrying capacity of steel columns exposed to fire. Thus, investigating the structural response of cold-formed steel (CFS) columns is gaining more interest due to the nature of such structural elements.Design/methodology/approach: In this study, experiments were conducted on two CFS configurations: back-to-back (B-B) channel and toe-to-toe (T-T) channel sections. All CFS column specimens were exposed to different temperatures following the standard fire curve and cooled by air or water. A total of 14 tests were conducted to evaluate the capacity of the CFS sections. The axial resistance and yield deformation were noted for both section types at elevated temperatures. The CFS column sections were modelled to simulate the section's behaviour under various temperature exposures using the general-purpose finite element (FE) program ABAQUS. The results from FE modelling agreed well with the experimental results. Ultimate load of experiment and finite element model (FEM) are compared with each other. The difference in percentage and ratio between both are presented.Findings: The results showed that B-B configuration showed better performance for all the investigated parameters than T-T sections. A noticeable loss in the ultimate strength of 34.5 and 65.6% was observed at 90 min (986℃) for B-B specimens cooled using air and water, respectively. However, the reduction was 29.9 and 46% in the T-T configuration, respectively.Originality/value: This research paper focusses on assessing the buckling strength of heated CFS sections to analyse the mode of failure of CFS sections with B-B and T-T design configurations under the effect of elevated temperature.