Determination The Cooling Capacity of The Fan Coil Unit (FCU) in A Hotel Room - Based on Heat Transfer Analysis
Open Access
- 30 March 2025
- journal article
- Published by Politeknik Negeri Bali in Logic : Jurnal Rancang Bangun dan Teknologi
- Vol. 25 (1) , 45-53
Abstract
Fan Coil Unit (FCU) with the appropriate cooling capacity is needed to obtain room thermal comfort. FCU installed based on the cooling load of the room. Cooling load is affected by room volume, material of : wall, floor, roof, equipment in a room, ventilation, infiltration, windows, outdoor air temperature and humidity, indoor air temperature and humidity. Appropriate and correct FCU installation will have an impact on the energy use of a building. Energy saving efforts are made when determining FCU capacity by calculating cooling load by analyzing heat transfer. This paper investigates and analyzes the amount of room cooling load using the CoolPack application. Calculation of cooling capacity using the CoolPack application is carried out after determining the thermal conductivity and material thickness, thermal resistance of the inner surface and outer surface of the wall, roof, floor, and heat transfer coefficient. Based on the results of calculations and analysis, it was concluded that the total cooling load was 3.58 kW. Furthermore, the FCU capacity to be installed must match the FCU capacity available on the market and be greater than the total cooling load in order to achieve the expected comfort. Proper and correct installation of FCUs will have an impact on energy use in a building is an effort to implement energy saving.Keywords
This publication has 9 references indexed in Scilit:
- Analisa kinerja cooling tower tipe counter flow induced draftJournal of Applied Mechanical Engineering and Green Technology, 2021
- Experimental and numerical studies of heat and mass transfer performance and design optimization of Fan-coil with high supply chilled water temperature in Air-Conditioning systemSustainable Energy Technologies and Assessments, 2021
- Measurement and optimization on the energy consumption of fans in semiconductor cleanroomsBuilding and Environment, 2021
- ANALYSIS OF HEAT AND MASS TRANSFER ON COOLING TOWER FILLJurnal Forum Nuklir, 2020
- A review on energy consumption in the residential and commercial buildings located in tropical regions of Indian Ocean: A case of Madagascar islandJournal of Energy Storage, 2019
- Study on a fan coil unit and chiller by an intelligent control method with a stepless variable speed driving technologyBuilding and Environment, 2018
- A review of different strategies for HVAC energy savingEnergy Conversion and Management, 2014
- Experimental analysis on pressure drop and heat transfer of a terminal fan-coil unit with ice slurry as cooling mediumInternational Journal of Refrigeration, 2010
- Thermal comfort and indoor air quality in the lecture room with 4-way cassette air-conditioner and mixing ventilation systemBuilding and Environment, 2007