Luh Putu Ike Midiani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Luh Putu Ike Midiani has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- I Gusti Agung Baagus Wirajati
Politeknik Negeri Bali
2 shared publications I Nyoman Gunung
Politeknik Negeri Bali
2 shared publicationsI Wayan Adi Subagia
2 shared publications- Made Ery Arsana
Department of Mechanical Engineering, Politeknik Negeri Bali, Jalan Kampus Bukit Jimbaran, Kuta Selatan, Badung, Bali, 80363 Indonesia
2 shared publications - I Dewa Made Cipta Santosa
Mechanical Engineering Department, Politeknik Negeri Bali, Kampus Bukit Jimbaran Kuta Selatan, Badung, Bali, 80364 Indonesia
1 shared publication I Gede Artha Negara
1 shared publication
Latest Publications
- Open Access
- 31 October 2025
- Published by Atlantis Press SARL
- p. 441-450
Analysis of Bio Phase Change Material (PCM) Utilisation in Air Conditioning System on Energy Consumption
- 31 October 2025
- Published by Atlantis Press SARL
- p. 441-450
Open AccessAnalysis of Bio Phase Change Material (PCM) Utilisation in Air Conditioning System on Energy Consumption
- Open Access
- 30 March 2025
- Published by Politeknik Negeri Bali in Logic : Jurnal Rancang Bangun dan Teknologi
- Vol. 25 (1) , 45-53
Determination The Cooling Capacity of The Fan Coil Unit (FCU) in A Hotel Room - Based on Heat Transfer Analysis
Fan Coil Unit (FCU) with the appropriate cooling capacity is needed to obtain room thermal comfort. FCU installed based on the cooling load of the room. Cooling load is affected by room volume, material of : wall, floor, roof, equipment in a room, ventilation, infiltration, windows, outdoor air temperature and humidity, indoor air temperature and humidity. Appropriate and correct FCU installation will have an impact on the energy use of a building. Energy saving efforts are made when determining FCU capacity by calculating cooling load by analyzing heat transfer. This paper investigates and analyzes the amount of room cooling load using the CoolPack application. Calculation of cooling capacity using the CoolPack application is carried out after determining the thermal conductivity and material thickness, thermal resistance of the inner surface and outer surface of the wall, roof, floor, and heat transfer coefficient. Based on the results of calculations and analysis, it was concluded that the total cooling load was 3.58 kW. Furthermore, the FCU capacity to be installed must match the FCU capacity available on the market and be greater than the total cooling load in order to achieve the expected comfort. Proper and correct installation of FCUs will have an impact on energy use in a building is an effort to implement energy saving.
- 30 March 2025
- Published by Politeknik Negeri Bali in Logic : Jurnal Rancang Bangun dan Teknologi
- Vol. 25 (1) , 45-53
Open AccessDetermination The Cooling Capacity of The Fan Coil Unit (FCU) in A Hotel Room - Based on Heat Transfer Analysis
Fan Coil Unit (FCU) with the appropriate cooling capacity is needed to obtain room thermal comfort. FCU installed based on the cooling load of the room. Cooling load is affected by room volume, material of : wall, floor, roof, equipment in a room, ventilation, infiltration, windows, outdoor air temperature and humidity, indoor air temperature and humidity. Appropriate and correct FCU installation will have an impact on the energy use of a building. Energy saving efforts are made when determining FCU capacity by calculating cooling load by analyzing heat transfer. This paper investigates and analyzes the amount of room cooling load using the CoolPack application. Calculation of cooling capacity using the CoolPack application is carried out after determining the thermal conductivity and material thickness, thermal resistance of the inner surface and outer surface of the wall, roof, floor, and heat transfer coefficient. Based on the results of calculations and analysis, it was concluded that the total cooling load was 3.58 kW. Furthermore, the FCU capacity to be installed must match the FCU capacity available on the market and be greater than the total cooling load in order to achieve the expected comfort. Proper and correct installation of FCUs will have an impact on energy use in a building is an effort to implement energy saving.
- Open Access
- 10 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 128 (1) , 69-81
Development of an Automation System-Based Energy Saving Application Model in Tourism Village Accommodation
At this time the cost for energy is already significant in the operational costs of an accommodation in a tourist village. This research is a modelling analysis to obtain a Net Zero Energy system with the application of automation system in increasing energy savings for tourism accommodation in several tourist villages as a case study. The energy used is sourced from a combination of solar energy and electric national grid. Significant energy saving strategies and efforts in traditional Balinese buildings will also be analysed in this study. Further analysis of the data obtained will be compared with the reference green building model so that the model can be applied to achieve every traditional Balinese style building in implementing green building standards. The expected result of this research is to obtain an energy saving system with the Internet of Thing (IoT) application in Bali which is used as tourism accommodation as well as energy saving procedures from the aspect of equipment and occupant behaviour.
- 10 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 128 (1) , 69-81
Open AccessDevelopment of an Automation System-Based Energy Saving Application Model in Tourism Village Accommodation
At this time the cost for energy is already significant in the operational costs of an accommodation in a tourist village. This research is a modelling analysis to obtain a Net Zero Energy system with the application of automation system in increasing energy savings for tourism accommodation in several tourist villages as a case study. The energy used is sourced from a combination of solar energy and electric national grid. Significant energy saving strategies and efforts in traditional Balinese buildings will also be analysed in this study. Further analysis of the data obtained will be compared with the reference green building model so that the model can be applied to achieve every traditional Balinese style building in implementing green building standards. The expected result of this research is to obtain an energy saving system with the Internet of Thing (IoT) application in Bali which is used as tourism accommodation as well as energy saving procedures from the aspect of equipment and occupant behaviour.
- Open Access
- 4 December 2023
- Published by Politeknik Negeri Bali in Logic : Jurnal Rancang Bangun dan Teknologi
- Vol. 23 (3) , 203-211
Design of Clean Water Booster Pump for High-Rise Buildings
A sanitary system is a supporting component designed to meet the clean water requirements of a building, primarily for sanitation activities. The average sanitary equipment used typically requires a shower pressure of ±1 Bar. However, the shower pressure can be significantly affected by factors such as the distance from the top tank and the building's layout, considering only the pressure due to gravity. To address inadequate shower pressure, an auxiliary pump known as a booster pump is necessary. The need for a booster pump is determined by the cumulative demand from plumbing equipment, where the total capacity required is 6057 liters/hour. To address this demand, the system employs two pump units, each with a capacity of 3 m3/hour. The distribution pipes utilized in the system adhere to established standards and are made of random polypropylene with a diameter of 2 inches and a flow rate of 0.005889 m3/second. The overall head loss resulting from this installation amounts to 31.62 meters. To accommodate the booster system, a pressure tank with a capacity of 67 liters is employed. The minimum working pressure required for the pumps is 1.8 Bar.
- 4 December 2023
- Published by Politeknik Negeri Bali in Logic : Jurnal Rancang Bangun dan Teknologi
- Vol. 23 (3) , 203-211
Open AccessDesign of Clean Water Booster Pump for High-Rise Buildings
A sanitary system is a supporting component designed to meet the clean water requirements of a building, primarily for sanitation activities. The average sanitary equipment used typically requires a shower pressure of ±1 Bar. However, the shower pressure can be significantly affected by factors such as the distance from the top tank and the building's layout, considering only the pressure due to gravity. To address inadequate shower pressure, an auxiliary pump known as a booster pump is necessary. The need for a booster pump is determined by the cumulative demand from plumbing equipment, where the total capacity required is 6057 liters/hour. To address this demand, the system employs two pump units, each with a capacity of 3 m3/hour. The distribution pipes utilized in the system adhere to established standards and are made of random polypropylene with a diameter of 2 inches and a flow rate of 0.005889 m3/second. The overall head loss resulting from this installation amounts to 31.62 meters. To accommodate the booster system, a pressure tank with a capacity of 67 liters is employed. The minimum working pressure required for the pumps is 1.8 Bar.
- Open Access
- 1 November 2023
- Published by Politeknik Negeri Lhokseumawe in Jurnal Vokasi
- Vol. 7 (3) , 291-297
PKM PENGGUNAAN LAMPU PENERANGAN JALAN TENAGA SURYA UNTUK MENDUKUNG KAWASAN WISATA EDUKASI SUBAK TEBA MAJELANGU DESA KESIMAN KERTALANGU
Kawasan Wisata Subak Teba Majelangu di Desa Kesiman Kertalangu terletak di wilayah dengan keterbatasan jaringan listrik. Minimnya pencahayaan di jalan-jalan daerah ini mengakibatkan terganggunya kenyamanan dan keamanan dalam beraktivitas, terutama saat sore menjelang malam hari. Berdasarkan kondisi tersebut tim pengabdian dari Prodi Teknologi Rekayasa Utilitas Jurusan Teknik Mesin Politeknik Negeri Bali melakukan Pengabdian kepada Masyarakat (PkM) dengan menyediakan lampu penerangan jalan tenaga surya di kawasan Wisata Edukasi Subak Teba Majelangu. Kegiatan PkM melewati serangkaian tahapan sebagai berikut : 1) analisis situasi, 2) penentuan kebutuhan daya lampu, 3) persiapan peralatan, 4) instalasi dan pemeliharaan, 5) evaluasi dan monitoring. Hasil yang dicapai adalah pemasangan lampu penerangan jalan tenaga surya di kawasan Wisata Edukasi Subak Teba Majelangu Desa Kesiman Kertalangu, yang mampu memberikan penerangan yang memadai di malam hari untuk jalan dan area sekitarnya, serta memiliki durasi pencahayaan yang panjang. Pemasangan lampu penerangan jalan tenaga surya merupakan implementasi penggunaan energi terbarukan dalam upaya pelestarian lingkungan..
- 1 November 2023
- Published by Politeknik Negeri Lhokseumawe in Jurnal Vokasi
- Vol. 7 (3) , 291-297
Open AccessPKM PENGGUNAAN LAMPU PENERANGAN JALAN TENAGA SURYA UNTUK MENDUKUNG KAWASAN WISATA EDUKASI SUBAK TEBA MAJELANGU DESA KESIMAN KERTALANGU
Kawasan Wisata Subak Teba Majelangu di Desa Kesiman Kertalangu terletak di wilayah dengan keterbatasan jaringan listrik. Minimnya pencahayaan di jalan-jalan daerah ini mengakibatkan terganggunya kenyamanan dan keamanan dalam beraktivitas, terutama saat sore menjelang malam hari. Berdasarkan kondisi tersebut tim pengabdian dari Prodi Teknologi Rekayasa Utilitas Jurusan Teknik Mesin Politeknik Negeri Bali melakukan Pengabdian kepada Masyarakat (PkM) dengan menyediakan lampu penerangan jalan tenaga surya di kawasan Wisata Edukasi Subak Teba Majelangu. Kegiatan PkM melewati serangkaian tahapan sebagai berikut : 1) analisis situasi, 2) penentuan kebutuhan daya lampu, 3) persiapan peralatan, 4) instalasi dan pemeliharaan, 5) evaluasi dan monitoring. Hasil yang dicapai adalah pemasangan lampu penerangan jalan tenaga surya di kawasan Wisata Edukasi Subak Teba Majelangu Desa Kesiman Kertalangu, yang mampu memberikan penerangan yang memadai di malam hari untuk jalan dan area sekitarnya, serta memiliki durasi pencahayaan yang panjang. Pemasangan lampu penerangan jalan tenaga surya merupakan implementasi penggunaan energi terbarukan dalam upaya pelestarian lingkungan..
- Open Access
- 25 November 2022
- Published by Scientific and Literature Open Access Publishing in International research journal of engineering, IT and scientific research
- Vol. 8 (6) , 323-332
Design of sintered zeolite evaporative cooling system
An evaporative cooling system for fruit and vegetable was designed, fabricated, and evaluated in this study. The evaporative cooling system is made of plywood covered with steorofoam. The inside system is made of plywood with dimensions of 30 cm x 30 cm x 30 cm. The inside of the box is covered with steorofoam with a thickness of 2 cm on the front, sides and back. The cooling pad in this evaporative cooling system is sintered zeolite. Sintering zeolite is a new material used to optimize evaporative cooling systems. One suction fan to draw environmental air through the cooling pad and into the controlled room. There is a water reservoir used to collect cooling water and place a cooling water circulation pump. The pump lifts water from the reservoir then sprays the cooling pad through the pipe and then the water is stored back in the reservoir. As water drips through the cooling pad, the suction fan keeps the air moving and blowing through the cooling pad. When passing through the cooling pad, the evaporation process occurs, and the cooling effect takes place.
- 25 November 2022
- Published by Scientific and Literature Open Access Publishing in International research journal of engineering, IT and scientific research
- Vol. 8 (6) , 323-332
Open AccessDesign of sintered zeolite evaporative cooling system
An evaporative cooling system for fruit and vegetable was designed, fabricated, and evaluated in this study. The evaporative cooling system is made of plywood covered with steorofoam. The inside system is made of plywood with dimensions of 30 cm x 30 cm x 30 cm. The inside of the box is covered with steorofoam with a thickness of 2 cm on the front, sides and back. The cooling pad in this evaporative cooling system is sintered zeolite. Sintering zeolite is a new material used to optimize evaporative cooling systems. One suction fan to draw environmental air through the cooling pad and into the controlled room. There is a water reservoir used to collect cooling water and place a cooling water circulation pump. The pump lifts water from the reservoir then sprays the cooling pad through the pipe and then the water is stored back in the reservoir. As water drips through the cooling pad, the suction fan keeps the air moving and blowing through the cooling pad. When passing through the cooling pad, the evaporation process occurs, and the cooling effect takes place.