Safety and efficacy of left bundle branch pacing in comparison with conventional right ventricular pacing
Authors:
- Xing LiuXLXing Liu
- Wenbin LiWLWenbin Li
- Lei WangLWLei Wang
- Shaohua TianSTShaohua Tian
- Xiaolin ZhouXZXiaolin Zhou
- Mingxing WuMWMingxing Wu
Open Access
- 9 July 2021
- journal article
- review article
- Published by Wolters Kluwer Health in Medicine
- Vol. 100 (27) , e26560
Abstract
Background: Right ventricular pacing (RVP) has been widely accepted as a traditional pacing strategy, but long-term RVP has detrimental impact on ventricular synchrony. However, left bundle branch pacing (LBBP) that evolved from His-bundle pacing could maintain ventricular synchrony and overcome its clinical deficiencies such as difficulty of lead implantation, His bundle damage, and high and unstable thresholds. This analysis aimed to appraise the clinical safety and efficacy of LBBP. Methods: The Medline, PubMed, Embase, and the Cochrane Library databases from inception to November 2020 were searched for studies comparing LBBP and RVP. Results: Seven trials with 451 patients (221 patients underwent LBBP and 230 patients underwent RVP) were included in the analysis. Pooled analyses verified that the paced QRS duration (QRSd) and left ventricular mechanical synchronization parameters of the LBBP capture were similar with the native-conduction mode (P > .7),but LBBP showed shorter QRS duration (weighted mean difference [WMD]: −33.32; 95% confidence interval [CI], −40.44 to −26.19, P < .001), better left ventricular mechanical synchrony (standard mean differences: −1.5; 95% CI: −1.85 to −1.14, P < .001) compared with RVP. No significant differences in Pacing threshold (WMD: 0.01; 95% CI: −0.08 to 0.09, P < .001), R wave amplitude (WMD: 0.04; 95% CI: −1.12 to 1.19, P = .95) were noted between LBBP and RVP. Ventricular impedance of LBBP was higher than that of RVP originally (WMD: 19.34; 95% CI: 3.13–35.56, P = .02), and there was no difference between the 2 groups after follow-up (WMD: 11.78; 95% CI: −24.48 to 48.04, P = .52). And follow-up pacing threshold of LBBP kept stability (WMD: 0.08; 95% CI: −0.09 to 0.25, P = .36). However, no statistical difference existed in ejection fraction between the 2 groups (WMD: 1.41; 95% CI: −1.72 to 4.54, P = .38). Conclusions: The safety and efficacy of LBBP was firstly verified by meta-analysis to date. LBBP markedly preserve ventricular electrical and mechanical synchrony compared with RVP. Meanwhile, LBBP had stable and excellent pacing parameters. However, LBBP could not be significant difference in ejection fraction between RVP during short- term follow-up.Keywords
Funding Information
- Science and Technology Department of Hunan Province (2018SK52104)
This publication has 35 references indexed in Scilit:
- Detecting small‐study effects and funnel plot asymmetry in meta‐analysis of survival data: A comparison of new and existing testsResearch Synthesis Methods, 2017
- Avoiding non-responders to cardiac resynchronization therapy: a practical guideEuropean Heart Journal, 2016
- Heart failure due to right ventricular apical pacing: the importance of flow patternsEP Europace, 2016
- 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failureEuropean Heart Journal, 2016
- The risk of atrial fibrillation during right ventricular pacingEP Europace, 2015
- Quantifying the risk of error when interpreting funnel plotsSystematic Reviews, 2015
- PR Interval Identifies Clinical Response in Patients With Non–Left Bundle Branch BlockCirculation: Arrhythmia and Electrophysiology, 2014
- Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analysesEuropean Journal of Epidemiology, 2010
- Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure EventsNew England Journal of Medicine, 2009
- The anatomy of the cardiac conduction systemClinical Anatomy, 2008