MWMingxing Wu

Mingxing Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mingxing Wu has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Association of the weight-adjusted waist index and obstructive sleep apnea in adults

    by Si Pang, Haobo Huang, Yunlong Zhu, Mingxing Wu

    The weight-adjusted waist index (WWI) has gained attention as an innovative anthropometric metric that may offer superior assessment of central obesity compared to conventional measures. This study aims to explore the correlation between WWI and obstructive sleep apnea (OSA) across a broad range of the American population, seeking to uncover any potential associations between these variables. Using a weighted multivariate logistic regression approach, the analysis examined the association between WWI and OSA among adult participants in the National Health and Nutrition Examination Survey. Data collection spanned 2 intervals: 2005 to 2008 and 2015 to 2020. The study employed smoothed curve fitting, subgroup analyses, threshold effect assessments, and interaction tests to conduct a thorough investigation. This comprehensive methodology enabled an in-depth exploration of the relationship between the variables. Among 21,382 participants, the study identified a significant association between WWI and OSA, with an odds ratio of 1.38 (95% confidence interval: 1.27, 1.51). Notably, there were significant interactions across gender and age groups, but not within subgroups based on hypertension, diabetes, or body mass index status. Furthermore, a U-shaped correlation between WWI and OSA was observed in elderly individuals, while an inverted U-shaped pattern emerged among males, with inflection points at 10.45 cm/√kg for the elderly and 12.49 cm/√kg for males. The higher WWI ratio is nonlinearly associated with OSA among adults in the US. Implementing moderate interventions to manage WWI may help reduce the incidence of OSA, especially in individuals aged 70 and older.

  • Open Access

    Takotsubo syndrome following mitral transcatheter edge-to-edge repair: a case report and literature review

    by Si Pang, Haobo Huang, Yunlong Zhu, Rong Zhou, Dan Tan, Yuqing Zhang, Mingxing Wu

    Background: Takotsubo syndrome (TTS), characterized by transient wall motion aberrations and clinical manifestations akin to acute coronary syndrome, predominantly arises from significant physical or emotional stress, often throughout the perioperative period. The prevalence and mechanisms of this condition remain inadequately elucidated, particularly in the context of transcatheter valvular disease procedures. This knowledge gap may result in under-recognition and subsequent delays in diagnosis.Case summary: A 76-year-old female was scheduled in our department for mitral transcatheter edge-to-edge repair (TEER). Despite the procedural success, multi-lead T-wave inversions and a 43% decrease in ejection fraction accompanied by new apical hypokinesis were noted postoperatively. Subsequent assessment revealed TTS. After receiving the optimal medical therapy, the patient was discharged after 10 days without experiencing acute chest pain or shortness of breath. The patient’s electrocardiogram (ECG) and function of the left ventricular function, particularly regional wall motion abnormalities, recovered on the 20th day after surgery.Discussion: The limited literature reporting TTS post-TEER that we reviewed suggests that this rare complication must be anticipated in patients exhibiting an unexpected postoperative ECG and impaired myocardial contraction.Conclusion: Researchers call for high-risk patient identification, adequate preoperative evaluation, and vigilant postoperative monitoring, and note the significance of early detection in optimizing therapeutic outcomes. Further research is imperative to further explore the management and prognosis of TTS following TEER.


  • Open Access

    Comparison of clinical outcomes of Ibutilide-guided cardioversion and direct current synchronized cardioversion after radiofrequency ablation of persistent atrial fibrillation

    by Xing Liu, Yan He, Chun Gui, Weiming Wen, Zhiyuan Jiang, Guoqiang Zhong, Mingxing Wu

    Backgroup: Ibutilide has already been used for cardioversion of persistent atrial fibrillation (PsAF) after radiofrequency catheter ablation (RFCA). The purpose of this study was to determine the effect of Ibutilide-guided cardioversion on clinical outcomes after individualized ablation of PsAF.Methods: From October 2020 to September 2021, consecutive patients with PsAF accepted for RFCA were prospectively enrolled. After individualized ablation including pulmonary vein isolation plus left atrial roof line ablation and personalized linear ablation based on left atrial low-voltage zones, patients were divided into the spontaneous conversion (SCV) group, direct current synchronized cardioversion (DCC) group and Ibutilide group according to different cardioversion types during ablation. The rates of freedom from atrial tachyarrhythmia (ATT) among the three groups were evaluated after follow-up.Results: In this study, 110 patients were enrolled, including 12 patients with SCV, 50 patients receiving DCC and 48 patients receiving Ibutilide cardioversion after individualized ablation. Among the three groups, the SCV group had shorter AF duration {12 months [interquartile range (IQR) 12–16], P = 0.042} and smaller left atrial diameter (LAD) [35 mm (IQR: 33–42), P = 0.023]. A 12-month freedom from ATT rate was 83.3% in SCV group, 69.4% in DCC group, and 79.2% in Ibutilide group, respectively (Log-rank, P = 0.745). During the follow-up [17 months (IQR: 15–19)], the rate of freedom from ATT of SCV group (83.3%), and Ibutilide group (72.9%) were both higher than that of DCC group (53.1%, P = 0.042). Moreover, Kaplan–Meier analysis showed a significantly higher sinus rhythm (SR) maintenance in Ibutilide group than in DCC group (Log-rank, P = 0.041). After adjusting for risk factors of AF recurrence, the hazard ratio for AF recurrence of the DCC group with reference to the Ibutilide group was 4.10 [95% confidence interval (CI) (1.87–8.98), P < 0.001]. Furthermore, subgroup analysis showed that freedom from ATT rate in effective Ibutilide subgroup was significantly higher than noneffective Ibutilide subgroup (Log-rank, P < 0.001).Conclusion: For the treatment of the patients with PsAF, Ibutilide-guided cardioversion after individualized RFCA may be benefit for maintenance of SR compared to conventional DCC, especially for the patients who are effective for administration of Ibutilide.


  • Open Access

    Bioinformatics analysis of the circRNA-miRNA-mRNA network for atrial fibrillation

    by Xing Liu, Yiqian Zeng, Zhao Liu, Wenbin Li, Lei Wang, Mingxing Wu

    Atrial fibrillation (AF) is a chronic and progressive disease, with advancing age, the morbidity of which will increase exponentially. Circular ribonucleic acids (RNAs; circRNAs) have gained a growing attention in the development of AF in recent years. The purpose of this study is to explore the mechanism of circRNA regulation in AF, in particular, the intricate interactions among circRNA, microRNA (miRNA), and messenger RNA (mRNA). Three datasets (GSE129409, GSE68475, and GSE79768) were obtained from the Gene Expression Omnibus database to screen differentially expressed (DE) circRNAs, DE miRNAs, and DE mRNAs in AF, respectively. Based on circRNA-miRNA pairs and miRNA-mRNA pairs, a competing endogenous RNAs (ceRNAs) network was built. Then, Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) functional enrichment analysis of DE mRNAs in the network were performed and protein-protein interaction (PPI) networks were established to identify hub genes. Finally, a circRNA-miRNA-hub gene subnetwork was constructed. A total of 103 DE circRNAs, 16 DE miRNAs, and 110 DE mRNAs were screened in AF. Next, ceRNAs network in AF was constructed with 3 upregulated circRNAs, 2 downregulated circRNAs, 2 upregulated miRNAs, 2 downregulated miRNAs, 17 upregulated mRNAs, and 24 downregulated mRNAs. Thirty GO terms and 6 KEGG pathways were obtained. Besides, 6 hub genes (C-X-C chemokine receptor type 4 [CXCR4], C-X-C chemokine receptor type 2 [CXCR2], C-X-C motif chemokine 11 [CXCL11], neuromedin-U, B1 bradykinin receptor, and complement C3) were screened from constructing a PPI network. Finally, a circRNA-miRNA-hub gene subnetwork with 10 regulatory axes was constructed to describe the interactions among the differential circRNAs, miRNA, and hub genes. We speculated that hsa_circRNA_0056281/hsa_circRNA_0006665 -hsa-miR-613-CXCR4/CXCR2/CXCL11 regulatory axes and hsa_circRNA_0003638-hsa-miR-1207-3p-CXCR4 regulatory axis may be associated with the pathogenesis of AF.


  • Open Access

    Clinical Outcomes of Left Bundle Branch Area Pacing in Comparison with Right Ventricular Septal Pacing in Patients with High Ventricular Pacing Ratio ≥40%

    by Xing Liu, Wenbin Li, Xiaolin Zhou, Haobo Huang, Lei Wang, Mingxing Wu

    Background: The aim of the present study is to compare the clinical outcomes between left bundle branch area pacing (LBBaP) and right ventricular septal pacing (RVSP) in patients with percent ventricular pacing (VP%) ≥ 40%. Methods: Fifty-four patients with VP% ≥ 40% were retrospectively studied, including 33 patients with LBBaP and 21 patients with RVSP. QRS duration (QRSd), interventricular mechanical delay (IVMD) and septal-posterior wall motion delay (SPWMD) were measured to evaluate ventricular synchrony. Heart failure hospitalization (HFH), pacing parameters, and complications were evaluated postoperatively and at follow-ups. Results: The mean follow-up duration of the study participants was 13.80 ± 4.47 months. In the LBBaP group, no significant differences were noted in paced QRSd, IVMD and SPWMD of the LBBaP capture and intrinsic-conduction modes, but the paced QRSd was narrower (QRSd, 110.88 ± 7.37 vs 132.90 ± 14.78 ms, P< 0.0001) and the IVMD and SPWMD were lower when compared with the RVSP group (IVMD, 28.16 ± 4.76 vs 40.28 ± 6.97 ms, P < 0.0001; SPWMD, 43.68 ± 26.41 vs 97.94 ± 12.77 ms, P < 0.0001). LBBaP was associated with better left ventricular function in comparison with RVSP during follow-ups (LVEDD, 47.09 ± 4.47 vs 51.28 ± 7.58, P = 0.017; LVEF, 64.81± 5.49 vs 60.44 ± 9.28, P = 0.041). Patients with LBBaP had lower occurrences of HFH than patients with RVSP (3.13% vs 27.78%, P = 0.034). Pacing parameters showed no differences between the two groups and remained stable throughout the study period. Conclusion: The results of this study suggest that LBBaP may be more suitable for patients requiring long-term high ventricular pacing ratio.


  • Open Access

    Evaluation of clinical safety and efficacy of left bundle branch area pacing in comparison with right ventricular septal pacing

    by Xing Liu, Wenbin Li, Jianping Zeng, He Huang, Lei Wang, Shaohua Tian, Mingxing Wu

    Left bundle branch area pacing (LBBaP) has recently emerged as a new physiological pacing strategy. The purpose of this study is to compare LBBaP with right ventricular sepal pacing (RVSP) in terms of their clinical safety and efficacy. From February 2019 to May 2020, consecutive pacing-indicated patients were prospectively enrolled and divided into 2 groups. Ventricular synchrony indexes such as QRS duration (QRSd), interventricular mechanical delay and septal-posterior wall motion delay, left ventricular function such as left ventricular end-diastolic diameter (LVEDD) and left ventricular ejection fraction (LVEF), pacing parameters, and complications were evaluated in the perioperative period and during follow-up. LBBaP was successful in 45 patients (88.2%), and finally 46 patients underwent RVSP. With LBBaP, ventricular electricalmechanical synchrony were similar to those of native-conduction system (P = .78). However, the ventricular electrical synchrony (QRSd, 108.47±7.64 vs 130.63±13.63ms, P < .001) and mechanical synchrony (interventricular mechanical delay, 27.68±4.33 vs 39.88±5.83, P < .001; septal-posterior wall motion delay, 40.39±23.21 vs 96.36±11.55, P < .001) in the LBBaP group were significantly better than those in the RVSP group. No significant differences in LVEDD (46 [44-48.5] vs 47 [44-52] mm, P = .49) and LVEF% (66 [62.5-70] vs 64 [61-68], P = .76) was observed between 2 groups at last follow-up. But, in the subgroup analysis, LVEDD was shorter (46 [44-49] vs 50 [47-58] mm, P = .03) and the LVEF% was higher (65 [62-68] vs 63 [58-65], P = .02) in the LBBaP-H (high ventricular pacing ratio >40%) group compared with RVSP-H group at last follow-up. There were lower capture thresholds (0.59±0.18V vs 0.71 ± 0.26 V, P = 0.01) at implantation in the LBBaP group than those in the RVSP group, with R-wave amplitudes and pacing impedances showing no significant difference between 2 groups. No serious complications were found in both 2 groups at implantation and follow-ups. This study confirms the clinical safety and efficacy of LBBaP, and it produces better ventricular electrical-mechanical synchrony than RVSP. The event of pacing-induced left ventricular dysfunction is lower in the LBBaP-H group than RVSP-H group.


  • Open Access

    The Construction and Comprehensive Analysis of a ceRNA Immunoregulatory Network and Tissue-Infiltrating Immune Cells in Atrial Fibrillation

    by Xing Liu, Guoqiang Zhong, Wenbin Li, Yiqian Zeng, Mingxing Wu

    Background: At present, the mechanisms behind atrial fibrillation (AF) pathogenesis are still unclear. We construct a ceRNA immunoregulatory network to further understand the mechanism of AF. Methods: Four AF mRNA datasets from the Gene Expression Omnibus (GEO) database were integrated by SVA method. AF-related immune genes (AF-IRGs) were selected via combining ImmPort database with the genes in the module most associated with AF obtained by a weighted gene coexpression network analysis (WGCNA). Then, circRNA and miRNA expressions from the GEO database were extracted and mapped with related databases. Next, an immune-related circRNA-miRNA-mRNA ceRNA network was constructed and hub genes were filtered from a protein–protein interaction (PPI) network, and the differentially expressed (DE) hub genes in AF were further screened. Additionally, immune infiltration was investigated in AF by using CIBERSORT. Subsequently, the relationships between DE hub genes and AF-related infiltrating immune cells were performed by using Pearson correlation coefficients. Ulteriorly, the immune-cells-related ceRNA subnetwork in AF was built. Results: A total of 95 AF-IRGs were detected, and an immune-related ceRNA network in AF was constructed with 12 circRNAs, 7 miRNAs and 50 mRNAs. The immune infiltration analysis indicated that a higher level of neutrophils, as well as a lower level of T cells regulatory (Tregs) and NK cells activated in AF. Four DE hub genes (CXCL12, IL7R, TNFSF13B, CD8A) were associated with Tregs or NK cells activated immune cells (P < 0.05). Tregs or NK cells activated immune cells-related ceRNA subnetwork including 5 circRNAs (has_circ_0001190, has_circ_0006725, has_circ_0079284, has_circ_0005299, and has_circ_0002103), 4 miRNAs (has-miR-198, has-miR-623, has-miR-1246, and has-miR-339-3p) and 4 DE hub genes was eventually constructed in AF. Conclusion: Our results provide new insights into the molecular mechanisms governing AF progression from the perspective of immune-related ceRNA network.


  • Open Access

    Safety and efficacy of left bundle branch pacing in comparison with conventional right ventricular pacing

    by Xing Liu, Wenbin Li, Lei Wang, Shaohua Tian, Xiaolin Zhou, Mingxing Wu

    Background: Right ventricular pacing (RVP) has been widely accepted as a traditional pacing strategy, but long-term RVP has detrimental impact on ventricular synchrony. However, left bundle branch pacing (LBBP) that evolved from His-bundle pacing could maintain ventricular synchrony and overcome its clinical deficiencies such as difficulty of lead implantation, His bundle damage, and high and unstable thresholds. This analysis aimed to appraise the clinical safety and efficacy of LBBP. Methods: The Medline, PubMed, Embase, and the Cochrane Library databases from inception to November 2020 were searched for studies comparing LBBP and RVP. Results: Seven trials with 451 patients (221 patients underwent LBBP and 230 patients underwent RVP) were included in the analysis. Pooled analyses verified that the paced QRS duration (QRSd) and left ventricular mechanical synchronization parameters of the LBBP capture were similar with the native-conduction mode (P > .7),but LBBP showed shorter QRS duration (weighted mean difference [WMD]: −33.32; 95% confidence interval [CI], −40.44 to −26.19, P < .001), better left ventricular mechanical synchrony (standard mean differences: −1.5; 95% CI: −1.85 to −1.14, P < .001) compared with RVP. No significant differences in Pacing threshold (WMD: 0.01; 95% CI: −0.08 to 0.09, P < .001), R wave amplitude (WMD: 0.04; 95% CI: −1.12 to 1.19, P = .95) were noted between LBBP and RVP. Ventricular impedance of LBBP was higher than that of RVP originally (WMD: 19.34; 95% CI: 3.13–35.56, P = .02), and there was no difference between the 2 groups after follow-up (WMD: 11.78; 95% CI: −24.48 to 48.04, P = .52). And follow-up pacing threshold of LBBP kept stability (WMD: 0.08; 95% CI: −0.09 to 0.25, P = .36). However, no statistical difference existed in ejection fraction between the 2 groups (WMD: 1.41; 95% CI: −1.72 to 4.54, P = .38). Conclusions: The safety and efficacy of LBBP was firstly verified by meta-analysis to date. LBBP markedly preserve ventricular electrical and mechanical synchrony compared with RVP. Meanwhile, LBBP had stable and excellent pacing parameters. However, LBBP could not be significant difference in ejection fraction between RVP during short- term follow-up.


  • Open Access

    Prospective evaluation of clinical safety and efficacy of left bundle branch area pacing in comparison with right ventricular sepal pacing

    by Xing Liu, Wenbin Li, Jianping Zeng, He Huang, Lei Wang, Shaohua Tian, Mingxing Wu

    BackgroundLeft bundle branch area pacing (LBBaP) has recently emerged as alternative a new physiologic strategy of pacing to His-bundle pacing (HBP) associated with difficulty of lead implantation, His bundle damage, high and unstable thresholds.ObjectiveThe purpose of this study is to compare clinical safety and efficacy of LBBaP with right ventricular sepal pacing (RVSP).MethodsFrom February 2019 to May 2020, consecutive pacing-indicated patients were prospectively enrolled and divided into two groups. Ventricular synchrony index such as QRS duration (QRSd), interventricular mechanical delay (IVMD) and septal-posterior wall motion delay (SPWMD), left ventricular function such as left ventricular end-diastolic diameter (LVEDD) and left ventricular ejection fraction (LVEF), pacing parameters, and complications were evaluated in perioperative period and during follow-up.ResultsLBBaP was successful in 45 patients (88.2%), and finally 46 patients underwent RVSP. With LBBaP, the ventricular electrical- mechanical synchrony were similar with the native-conduction system (P = .784). However, the ventricular electrical synchrony (QRSd, 108.47 ± 7.64 vs 130.63 ± 13.63 ms, P < .0001) and mechanical synchrony (IVMD, 27.68 ± 4.33 vs 39.88 ± 5.83, P < .0001; SPWMD, 40.39 ± 23.21 vs 96.36 ± 11.55, P < .0001) in the LBBaP group were significantly superior to the RVSP group. No significant differences in LVEDD (46 [44-48.5] vs 47 [44–52] mm, P = .488) and LVEF% (66 [62.5–70] vs 64 [61–68], P = .759) were noted in both two groups at last follow-up. But, in the subgroup analysis, LVEDD was shorter (46 [44–49] vs 50 [47–58] mm, P = .032) and the LVEF% was higher (65 [62–68] vs 63 [58–65], P = .022) in the LBBaP-H (high ventricular pacing ratio > 40%) group compared with RVSP-H group at last follow-up. There was lower capture thresholds (0.59 ± 0.18V vs. 0.71 ± 0.26V, P = 0.011) at implantation in the LBBaP group than RVSP group, and R-wave amplitudes and pacing impedances did not differ between the two groups. No serious complications were found in both two groups at implantation and follow-ups.ConclusionThis study confirms the clinical safety and efficacy of LBBaP, and that produces better ventricular electrical-mechanical synchrony than RVSP. The event of pacing-induced left ventricular dysfunction is lower in the LBBaP-H group than RVSP-H group.Trial registrationTrial registration Chinese Clinical Trial Registry, ChiCTR2100046901, Registered 30 May 2021—Retrospectively registered, http://www.chictr.org.cn/searchproj.aspx?regstatus=1008001.