Postoperative 320 multi-slice computed tomography in assessment of pedicle screw insertion in thoraco-lumbar fixation
Open Access
- 26 November 2019
- journal article
- research article
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 50 (1) , 1-10
Abstract
Background: Pedicle screw instrumentation is used widely in lumbar spine for stabilization to enhance arthrodesis and has been accepted in the thoracic spine in recent years. The purpose of this study was to assess the value of postoperative 320 multi-slice computed tomography (MSCT) in assessment of pedicle screw placement in patients with spinal fixation with clinical and surgical correlation. Results: A total of 340 pedicular screws were inserted to 70 cases. 286 (84.12%) were in, 54 screws (15.88%) were violated, and revision surgeries were required for 5 displaced screws. On axial, coronal reconstruction and three-dimensional (3D) reformatted CT images 36, 47, and 54 displaced screws were detected, respectively. Both sensitivity and specificity for 3D reformatted images were 100%. For axial image, they were 97.6% and 89.4%, respectively, compared with surgical findings in 5 revised screws. Conclusion: Multi-slice CT scan is a valuable and valid postoperative assessment tool of accuracy of spinal pedicle screw placement.Keywords
This publication has 30 references indexed in Scilit:
- Role of postoperative multislice computed tomography in assessment of pedicle screw placement in spinal surgical fixationEgyptian Journal of Radiology and Nuclear Medicine, 2013
- Accuracy of Free-Hand Pedicle Screws in the Thoracic and Lumbar Spine: Analysis of 6816 Consecutive ScrewsNeurosurgery, 2011
- Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patientsJournal of Neurosurgery: Spine, 2010
- Image-guided pedicle screw insertion accuracy: a meta-analysisInternational Orthopaedics, 2009
- Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilizationEuropean Spine Journal, 2006
- Observer reliability in evaluating pedicle screw placement using computed tomographyInternational Orthopaedics, 2006
- Inter- and Intraobserver Reliability of Computed Tomography in Assessment of Thoracic Pedicle Screw PlacementSpine, 2003
- Lumbar pedicle: surgical anatomic evaluation and relationshipsEuropean Spine Journal, 2001
- Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patientsEuropean Spine Journal, 2000
- A Method for Radiographic Evaluation of Pedicle Screw Violation of the Vertebral EndplateSpine, 1996