Indirect Estimation of Breathing Rate Using Wearable Devices
Open Access
- 1 March 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Abstract
Wearable sensors can be exploited for the indirect estimation of physiological parameters, such as Breathing Rate (BR). Indeed, BR is a significative quantity for both general health status monitoring and diagnostic purposes; however, standard methods for its assessment are often uncomfortable and mainly used for punctual (or brief, anyway) measurements. This paper aims to perform an uncertainty analysis of BR indirect estimation made starting from electrocardiographic signals gathered through wearable sensors, namely a cardiac belt (Zephyr BioHarness 3.0) and a smartwatch (Samsung Galaxy Watch3). Three different estimation methods were employed, considering respiratory sinus arrhythmia (RSA), signal amplitude modulation (AM), and Machine Learning (ML)-based techniques. Finally, the Monte Carlo simulation method was exploited for the measurement uncertainty estimation, including both sensors (hardware) and algorithms (software) contributions in the measurement chain. The results show that both the considered sensors are quite accurate (almost null bias) and precise (±[3-5] bpm, depending on the estimation method) in the estimation of BR with the three different estimation algorithms. A slightly higher precision is obtained for the cardiac belt (a reduced 95% confidence interval is reported, with a maximum reduction of 4 bpm depending on the estimation algorithm), whose results are also more strongly correlated to the reference ones (Pearson’s correlation coefficient ≥0.75 in all the three methods). The Monte Carlo simulation evidenced that the ML-based method is the most robust with respect to the sensors uncertainty (with no differences in the output uncertainty with respect to the sensors uncertainty in input); moreover, the higher precision of the cardiac belt with respect to the smartwatch was confirmed (-1 bpm in the output uncertainty) if RSA- and AM-based methods are considered.Keywords
This publication has 33 references indexed in Scilit:
- Indirect Estimation of Breathing Rate through Wearable Devices2022
- Embroidered wearable Antenna-based sensor for Real-Time breath monitoringMeasurement, 2022
- Respiratory Rate Prediction Algorithm based on Pulse Oximeter2021
- Assessment of Heart Rate and Respiratory Rate for Perioperative Infants Based on ELC ModelIEEE Sensors Journal, 2021
- Driver fatigue transition prediction in highly automated driving using physiological featuresExpert Systems with Applications, 2020
- Recent development of respiratory rate measurement technologiesPhysiological Measurement, 2019
- Towards real-time respiratory motion prediction based on long short-term memory neural networksPhysics in Medicine & Biology, 2019
- The effectiveness of breathing patterns to control maternal anxiety during the first period of labor: A randomized controlled clinical trialComplementary Therapies in Clinical Practice, 2017
- Electrocardiogram-derived respiration in screening of sleep-disordered breathingJournal of Electrocardiology, 2011
- Estimation of Breathing Rate from Respiratory Sinus Arrhythmia: Comparison of Various MethodsAnnals of Biomedical Engineering, 2008