LPLuna Panni

Luna Panni

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luna Panni has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Measurement of Spatio-Temporal Gait Parameters Through a Wearable Device for the Evaluation of the Activity Level of Athletes

    by Luna Panni, Gloria Cosoli, Marco Arnesano, Federico Citarelli, Luca Antognoli, Lorenzo Scalise

    Wearable technologies support athletes and coaches by providing objective data to enhance performance, prevent injuries, and optimize training. Magnetic and Inertial Measurement Units (MIMUs) measure spatio-temporal parameters, enabling the analysis of gait events outside laboratory settings. Recently, manufacturers have introduced single-point inertial sensors worn on the upper torso, gaining popularity in sports. Integrating machine learning (ML) algorithms has further revolutionized sport performance analysis. This paper presents the development and validation of a measurement method using a MIMU sensor on the upper torso to estimate gait parameters, particularly stride duration during walking and running. Data from the MIMU device is compared with that from sensorized insoles, and a metrological characterization assesses the device’s accuracy and reliability. Furthermore, the study developed ML models to classify the athlete’s activity level at three intensities: resting, walking (0 < speed ≤ 5 km/h), and running (speed > 5 km/h). Results show that the wearable sensor is accurate (bias: -0.002 s and almost 0 s for left and right feet, respectively) and precise (standard deviation of residuals: 0.07 s and 0.05 s for left and right feet) in estimating stride duration. Bland-Altman plots confirm agreement with the reference device, and Pearson’s correlation coefficients indicate strong linear correlation (0.94 and 0.97 for left and right feet). The ML-based classifier achieves an overall accuracy of 78%. Thus, the MIMU sensor placed at the upper torso effectively identifies stride duration, and the combination with the ML classifier advances wearable activity monitoring.These findings highlight the practical applicability of the proposed approach for continuous, non-invasive monitoring of athletes’ training load and movement patterns, offering a portable solution for performance optimization and injury prevention.

  • Open Access

    Indirect Estimation of Breathing Rate Using Wearable Devices

    by Gloria Cosoli, Luca Antognoli, Luna Panni, Lorenzo Scalise

    Wearable sensors can be exploited for the indirect estimation of physiological parameters, such as Breathing Rate (BR). Indeed, BR is a significative quantity for both general health status monitoring and diagnostic purposes; however, standard methods for its assessment are often uncomfortable and mainly used for punctual (or brief, anyway) measurements. This paper aims to perform an uncertainty analysis of BR indirect estimation made starting from electrocardiographic signals gathered through wearable sensors, namely a cardiac belt (Zephyr BioHarness 3.0) and a smartwatch (Samsung Galaxy Watch3). Three different estimation methods were employed, considering respiratory sinus arrhythmia (RSA), signal amplitude modulation (AM), and Machine Learning (ML)-based techniques. Finally, the Monte Carlo simulation method was exploited for the measurement uncertainty estimation, including both sensors (hardware) and algorithms (software) contributions in the measurement chain. The results show that both the considered sensors are quite accurate (almost null bias) and precise (±[3-5] bpm, depending on the estimation method) in the estimation of BR with the three different estimation algorithms. A slightly higher precision is obtained for the cardiac belt (a reduced 95% confidence interval is reported, with a maximum reduction of 4 bpm depending on the estimation algorithm), whose results are also more strongly correlated to the reference ones (Pearson’s correlation coefficient ≥0.75 in all the three methods). The Monte Carlo simulation evidenced that the ML-based method is the most robust with respect to the sensors uncertainty (with no differences in the output uncertainty with respect to the sensors uncertainty in input); moreover, the higher precision of the cardiac belt with respect to the smartwatch was confirmed (-1 bpm in the output uncertainty) if RSA- and AM-based methods are considered.