Abstract
Of the many metabolites involved in any clinical condition, only a narrow range of biomarkers is currently being used in the clinical setting. A key to personalized medicine would be to extend this range. Metabolic fingerprinting provides a more comprehensive insight, but many methods used for metabolomics analysis are too complex and time-consuming to be diagnostically useful. Here, a rapid evaporative ionization mass spectrometry (REIMS) system for direct ex vivo real-time analysis of biofluids with minor sample pretreatment is detailed. The REIMS can be linked to various laser wavelength systems (such as optical parametric oscillator or CO2 laser) and with automation for high-throughput analysis. Laser-induced sample evaporation occurs within seconds through radiative heating with the plume guided to the MS instrument. The presented procedure includes (i) laser setup with automation, (ii) analysis of biofluids (blood/urine/stool/saliva/sputum/breast milk) and (iii) data analysis. We provide the optimal settings for biofluid analysis and quality control, enabling sensitive, precise and robust analysis. Using the automated setup, 96 samples can be analyzed in ~35–40 min per ionization mode, with no intervention required. Metabolic fingerprints are made up of 2,000–4,000 features, for which relative quantification can be achieved at high repeatability when total ion current normalization is applied. With saliva and feces as example matrices, >70% of features had a coefficient of variance ≤30%. However, to achieve acceptable long-term reproducibility, additional normalizations by, e.g., LOESS are recommended, especially for positive ionization.Keywords
This publication has 44 references indexed in Scilit:
- Development of Isotope Labeling LC–MS for Human Salivary Metabolomics and Application to Profiling Metabolome Changes Associated with Mild Cognitive ImpairmentAnalytical Chemistry, 2012
- Extended international (IOTF) body mass index cut‐offs for thinness, overweight and obesityPediatric Obesity, 2012
- In Situ, Real-Time Identification of Biological Tissues by Ultraviolet and Infrared Laser Desorption Ionization Mass SpectrometryAnalytical Chemistry, 2011
- MZmine 2: Modular framework for processing, visualizing, and analyzing mass spectrometry-based molecular profile dataBMC Bioinformatics, 2010
- Partial least squares regression and projection on latent structure regression (PLS Regression)WIREs Computational Statistics, 2010
- References for growth and pubertal development from birth to 21 years in Flanders, BelgiumAnnals of Human Biology, 2009
- In Vivo, In Situ Tissue Analysis Using Rapid Evaporative Ionization Mass SpectrometryAngewandte Chemie International Edition, 2009
- Coupling desorption electrospray ionisation and neutral desorption/extractive electrospray ionisation with a travelling‐wave based ion mobility mass spectrometer for the analysis of drugsRapid Communications in Mass Spectrometry, 2007
- OPLS discriminant analysis: combining the strengths of PLS‐DA and SIMCA classificationJournal of Chemometrics, 2006
- XCMS: Processing Mass Spectrometry Data for Metabolite Profiling Using Nonlinear Peak Alignment, Matching, and IdentificationAnalytical Chemistry, 2006