Margot De Spiegeleer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Margot De Spiegeleer has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Lynn Vanhaecke
Laboratory of Integrative Metabolomics, Department of Translational Physiology, Infectiology and Public Health, Ghent University, Ghent, Belgium
6 shared publications - Marilyn De Graeve
Institute for Biomedicine, Eurac Research, Bolzano, Italy
5 shared publications - Kathleen Wijnant
Ghent University
3 shared publications - Nathalie Michels
Ghent University
3 shared publications - Inge Gies
Division of Paediatric Endocrinology, Universitair Ziekenhuis Brussel (UZ Brussel), Brussels Health Campus, Laarbeeklaan 101, 1090 Brussels, Belgium
2 shared publications - Karen De Clerck
Center For Textile Science and Engineering Department of Materials, Textiles and Chemical Engineering Ghent University Ghent Belgium
2 shared publications
Latest Publications
- Open Access
- 17 September 2023
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 168, 117287
Recent advances in high-throughput biofluid metabotyping by direct infusion and ambient ionization mass spectrometry
- 17 September 2023
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 168, 117287
Open AccessRecent advances in high-throughput biofluid metabotyping by direct infusion and ambient ionization mass spectrometry
- Open Access
- 9 June 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (23) , eade9933
Point-of-care applicable metabotyping using biofluid-specific electrospun MetaSAMPs directly amenable to ambient LA-REIMS
In recent years, ambient ionization mass spectrometry (AIMS) including laser ablation rapid evaporation IMS, has enabled direct biofluid metabolome analysis. AIMS procedures are, however, still hampered by both analytical, i.e., matrix effects, and practical, i.e., sample transport stability, drawbacks that impede metabolome coverage. In this study, we aimed at developing biofluid-specific metabolome sampling membranes (MetaSAMPs) that offer a directly applicable and stabilizing substrate for AIMS. Customized rectal, salivary, and urinary MetaSAMPs consisting of electrospun (nano)fibrous membranes of blended hydrophilic (polyvinylpyrrolidone and polyacrylonitrile) and lipophilic (polystyrene) polymers supported metabolite absorption, adsorption, and desorption. Moreover, MetaSAMP demonstrated superior metabolome coverage and transport stability compared to crude biofluid analysis and was successfully validated in two pediatric cohorts (MetaBEAse, n = 234 and OPERA, n = 101). By integrating anthropometric and (patho)physiological with MetaSAMP-AIMS metabolome data, we obtained substantial weight-driven predictions and clinical correlations. In conclusion, MetaSAMP holds great clinical application potential for on-the-spot metabolic health stratification.
- 9 June 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (23) , eade9933
Open AccessPoint-of-care applicable metabotyping using biofluid-specific electrospun MetaSAMPs directly amenable to ambient LA-REIMS
In recent years, ambient ionization mass spectrometry (AIMS) including laser ablation rapid evaporation IMS, has enabled direct biofluid metabolome analysis. AIMS procedures are, however, still hampered by both analytical, i.e., matrix effects, and practical, i.e., sample transport stability, drawbacks that impede metabolome coverage. In this study, we aimed at developing biofluid-specific metabolome sampling membranes (MetaSAMPs) that offer a directly applicable and stabilizing substrate for AIMS. Customized rectal, salivary, and urinary MetaSAMPs consisting of electrospun (nano)fibrous membranes of blended hydrophilic (polyvinylpyrrolidone and polyacrylonitrile) and lipophilic (polystyrene) polymers supported metabolite absorption, adsorption, and desorption. Moreover, MetaSAMP demonstrated superior metabolome coverage and transport stability compared to crude biofluid analysis and was successfully validated in two pediatric cohorts (MetaBEAse, n = 234 and OPERA, n = 101). By integrating anthropometric and (patho)physiological with MetaSAMP-AIMS metabolome data, we obtained substantial weight-driven predictions and clinical correlations. In conclusion, MetaSAMP holds great clinical application potential for on-the-spot metabolic health stratification.
- Open Access
- 24 April 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Point-of-care applicable metabotyping using biofluid-specific electrospun MetaSAMP®s directly amenable to ambient ionization mass spectrometry
While rapid analysis of the human biofluid metabolome is now possible using ambient ionization mass spectrometry (AIMS), these procedures are hampered by in-source matrix effects and reduced sample stability impeding metabolome coverage while remaining relatively labor-intensive. In this study, we aimed at developing biofluid-specific metabolome sampling membranes (MetaSAMP®s, WO2021/191467) that offer a directly applicable and stabilizing substrate for AIMS. Customized rectal, salivary and urinary MetaSAMP®s consisting of multilayered electrospun nanofibrous membranes of blended hydrophilic (polyvinylpyrrolidone and polyacrylonitrile) and lipophilic (polystyrene) polymers supported adequate metabolite ab- , ad-, and desorption. Moreover, MetaSAMP® demonstrated superior metabolome coverage and transport stability compared to crude biofluid analysis and was successfully validated in two pediatric cohorts (MetaBEAse, n=234, feces and urine; OPERA, n=138, saliva). By integrating anthropometric and (patho)physiological with MetaSAMP®-AIMS metabolome data, we obtained significant weight-driven predictions and clinical correlations. In conclusion, MetaSAMP® holds great clinical application potential for on-the-spot metabolic health stratification.
- 24 April 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessPoint-of-care applicable metabotyping using biofluid-specific electrospun MetaSAMP®s directly amenable to ambient ionization mass spectrometry
While rapid analysis of the human biofluid metabolome is now possible using ambient ionization mass spectrometry (AIMS), these procedures are hampered by in-source matrix effects and reduced sample stability impeding metabolome coverage while remaining relatively labor-intensive. In this study, we aimed at developing biofluid-specific metabolome sampling membranes (MetaSAMP®s, WO2021/191467) that offer a directly applicable and stabilizing substrate for AIMS. Customized rectal, salivary and urinary MetaSAMP®s consisting of multilayered electrospun nanofibrous membranes of blended hydrophilic (polyvinylpyrrolidone and polyacrylonitrile) and lipophilic (polystyrene) polymers supported adequate metabolite ab- , ad-, and desorption. Moreover, MetaSAMP® demonstrated superior metabolome coverage and transport stability compared to crude biofluid analysis and was successfully validated in two pediatric cohorts (MetaBEAse, n=234, feces and urine; OPERA, n=138, saliva). By integrating anthropometric and (patho)physiological with MetaSAMP®-AIMS metabolome data, we obtained significant weight-driven predictions and clinical correlations. In conclusion, MetaSAMP® holds great clinical application potential for on-the-spot metabolic health stratification.
- 2 August 2021
- Published by Springer Nature in Nature Protocols
- Vol. 16 (9) , 4327-4354
Rapid ex vivo molecular fingerprinting of biofluids using laser-assisted rapid evaporative ionization mass spectrometry
Of the many metabolites involved in any clinical condition, only a narrow range of biomarkers is currently being used in the clinical setting. A key to personalized medicine would be to extend this range. Metabolic fingerprinting provides a more comprehensive insight, but many methods used for metabolomics analysis are too complex and time-consuming to be diagnostically useful. Here, a rapid evaporative ionization mass spectrometry (REIMS) system for direct ex vivo real-time analysis of biofluids with minor sample pretreatment is detailed. The REIMS can be linked to various laser wavelength systems (such as optical parametric oscillator or CO2 laser) and with automation for high-throughput analysis. Laser-induced sample evaporation occurs within seconds through radiative heating with the plume guided to the MS instrument. The presented procedure includes (i) laser setup with automation, (ii) analysis of biofluids (blood/urine/stool/saliva/sputum/breast milk) and (iii) data analysis. We provide the optimal settings for biofluid analysis and quality control, enabling sensitive, precise and robust analysis. Using the automated setup, 96 samples can be analyzed in ~35–40 min per ionization mode, with no intervention required. Metabolic fingerprints are made up of 2,000–4,000 features, for which relative quantification can be achieved at high repeatability when total ion current normalization is applied. With saliva and feces as example matrices, >70% of features had a coefficient of variance ≤30%. However, to achieve acceptable long-term reproducibility, additional normalizations by, e.g., LOESS are recommended, especially for positive ionization.
- 2 August 2021
- Published by Springer Nature in Nature Protocols
- Vol. 16 (9) , 4327-4354
Rapid ex vivo molecular fingerprinting of biofluids using laser-assisted rapid evaporative ionization mass spectrometry
Of the many metabolites involved in any clinical condition, only a narrow range of biomarkers is currently being used in the clinical setting. A key to personalized medicine would be to extend this range. Metabolic fingerprinting provides a more comprehensive insight, but many methods used for metabolomics analysis are too complex and time-consuming to be diagnostically useful. Here, a rapid evaporative ionization mass spectrometry (REIMS) system for direct ex vivo real-time analysis of biofluids with minor sample pretreatment is detailed. The REIMS can be linked to various laser wavelength systems (such as optical parametric oscillator or CO2 laser) and with automation for high-throughput analysis. Laser-induced sample evaporation occurs within seconds through radiative heating with the plume guided to the MS instrument. The presented procedure includes (i) laser setup with automation, (ii) analysis of biofluids (blood/urine/stool/saliva/sputum/breast milk) and (iii) data analysis. We provide the optimal settings for biofluid analysis and quality control, enabling sensitive, precise and robust analysis. Using the automated setup, 96 samples can be analyzed in ~35–40 min per ionization mode, with no intervention required. Metabolic fingerprints are made up of 2,000–4,000 features, for which relative quantification can be achieved at high repeatability when total ion current normalization is applied. With saliva and feces as example matrices, >70% of features had a coefficient of variance ≤30%. However, to achieve acceptable long-term reproducibility, additional normalizations by, e.g., LOESS are recommended, especially for positive ionization.
- 1 April 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1108, 79-88
Impact of storage conditions on the human stool metabolome and lipidome: Preserving the most accurate fingerprint
- 1 April 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1108, 79-88
Impact of storage conditions on the human stool metabolome and lipidome: Preserving the most accurate fingerprint