JKJ. Christiaan Keurentjes

J. Christiaan Keurentjes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


J. Christiaan Keurentjes has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cemented total hip arthroplasty revisions in patients of eighty years and older

    by Martijn A. J. Te Stroet, Sushma A. Ghisai, J. Christiaan Keurentjes, Wim H. C. Rijnen, Jean W. M. Gardeniers, Albert Van Kampen, B. Willem Schreurs

    It is often a difficult decision whether it is safe to perform revision hip surgery in a patient of 80 years and older. Therefore we evaluated the results of cemented revisions in these elderly patients. Clinical data, radiographs and complications of 49 consecutive cup and/or stem revisions in 48 patients were prospectively collected. The average age of the patients at surgery was 84 years (range, 80–92). We performed Kaplan-Meier (KM) analysis and also a competing risk (CR) analysis because in this series the presence of a competing event (i.e. death) prevents the occurrence of endpoint rerevision. Twenty-nine patients (30 hips) died without rerevision during follow-up and their data was included. The average follow-up of the 16 surviving patients was eight years (range, six to 13). Six re-operations were performed, of which three were re-revisions. Eight-year survivorship was 91.6 % (95 % confidence interval (CI) 76–97 %) for endpoint re-revision for any reason. With the CR analysis we calculated that due to the increasing number of competing events, the KM analysis overestimates the failure rate with 32 % for this endpoint. The average Harris hip score improved from 49 to 74. Mortality within three months after surgery was 6 %. One postoperative fracture occurred and six hips dislocated. Cemented revisions can provide satisfying results in patient of 80 years and older with acceptable survivorship and complication rates.


  • High Incidence of Squeaking in THAs with Alumina Ceramic-on-ceramic Bearings

    by J. C. Keurentjes, R. M. Kuipers, D. J. Wever, B. W. Schreurs

    Nt 43 ceramic-on-ceramic noncemented THAs during the time of the study. Squeaking, defined as a reproducible sound of squeaking, clicking, or grating, occurred in nine of 43 implants (20.9%). Standard radiographs were normal. We used CT imaging to determine cup anteversion and inclination angles, comparing the squeaking hips with those of a randomly selected control group, but found no differences. We then hypothesized specific design features (stem size, cup size, head size, and neck length of the head) would be risk factors for squeaking. We found a difference in neck length between squeaking and nonsqueaking implants. A neck length of -4 mm or shorter resulted in a relative risk of 5.56 (95% confidence interval, 1.14-27.01) for squeaking. We found a high incidence of squeaking in our population, and we believe this phenomenon is an underreported side effect of these types of bearings. A short neck length of the femoral implant was a risk factor for squeaking in ceramic-on-ceramic THA. Level of Evidence: Level III, therapeutic study....