Fusion of Biplane Fluoroscopy With Fiber Bragg Grating for 3D Catheter Shape Reconstruction
- 2 July 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (4) , 6505-6512
Abstract
Nowadays, navigating therapeutic catheters takes place under 2D fluoroscopic imaging. This requires considerable training of the clinician and exposes him/her to X-ray radiation. Researchers have increasingly investigated alternative sensing techniques. In this respect Fiber Bragg Grating (FBG)-based shape sensing is gaining popularity. This paper proposes two approaches to fuse FBG with fluoroscropy, improve the understanding of the 3- dimensional shape while reducing fluoroscopy use. This paper proposes 2 FBG-fluoroscopy fusion approaches that combine fluoroscopy and FBG measurements. A comparison is performed between 3D shape reconstructions based on biplane fluoroscopy, rigidly fused multi-core FBG and dynamically fused FBG shape reconstruction. To verify the performance of the different approaches experiments were performed with custom made catheter in a CathLab on 3D printed tubes with known ground truth shape. The experiments showed overall acceptable errors for the targeted application with a maximum below 2 mm. The error of shape reconstruction through biplane fluoroscopy, rigid and dynamic fusion were found to be 1.51+-0.04 mm, 1.77+-0.29 mm and 1.47+-0.15 mm, respectively. Thus, FBG-fluoroscopy fusion offers comparable results to fluoroscopy and may substantially reduce the radiation dose through optimal acquisition frequency.Keywords
This publication has 23 references indexed in Scilit:
- Steerable Catheters in Cardiology: Classifying Steerability and Assessing Future ChallengesIEEE Transactions on Biomedical Engineering, 2016
- Robust Catheter and Guidewire Tracking Using B-Spline Tube Model and Pixel-Wise PosteriorsIEEE Robotics and Automation Letters, 2016
- New devices and technology in interventional cardiologyJournal of Cardiology, 2015
- Electromagnetic Tracking in Medicine—A Review of Technology, Validation, and ApplicationsIEEE Transactions on Medical Imaging, 2014
- Error Analysis of FBG-Based Shape Sensors for Medical Needle TrackingIEEE/ASME Transactions on Mechatronics, 2013
- Improving Frenet's Frame Using Bishop's FrameJournal of Mathematics Research, 2013
- Real‐time x‐ray fluoroscopy‐based catheter detection and tracking for cardiac electrophysiology interventionsMedical Physics, 2013
- A realistic elastic rod model for real-time simulation of minimally invasive vascular interventionsThe Visual Computer, 2010
- Three‐Dimensional Catheter Positioning During Radiofrequency Ablation in Patients: First Application of a Real‐Time Position Management SystemJournal of Cardiovascular Electrophysiology, 2000
- Multiscale vessel enhancement filtering1998