Abstract
The intra-layer no-insulation (LNI) method is effective for protecting a layer-wound REBCO coil from a quench. The most influential parameter is the electrical contact resistivity ct between the conductors and the copper sheets for current bypassing inside the winding. In previous work, an LNI-REBCO coil was protected from a 31.4 T quench, owing to a high ct value of 10,000 cm2. Thus, achieving the desired ct is of great importance for designing and fabricating an LNI-REBCO coil. In the present work, for obtaining basic knowledge on the behavior of the value of ct, we made a series of experiments; contact model experiment and coil experiment. The comparison between the experimental results in combination with a structural analysis suggests that the ct value of a coil does not follow a general electrical contact theory dominated by surface pressure; it is substantially affected by layer-to-layer contact conditions, resulting in being sensitive to external effects such as thermal cycling. The knowledge obtained in this work suggests that a solution to freeze the contact condition is required to control the value of ct.
Funding Information
  • JST-Mirai Program (JPMJMI17A2)
  • Special Postdoctoral Researcher Program in RIKEN

This publication has 14 references indexed in Scilit: