HMHideaki Maeda

Hideaki Maeda

*This is an algorithmically generated author record based on publicly available information.

Hideaki Maeda has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analyses of Deformation Due to Screening-Current-Induced Force in Layer-Wound REBCO Insert Coil for 1.3-GHz LTS/HTS NMR

    by Keisuke Naito, Ryo Harada, Ryota Inoue, SeokBeom Kim, Hiroshi Ueda, Yu Suetomi, Yoshinori Yanagisawa, Hideaki Maeda

    REBCO wires have high critical current density and thermal stability, and are being applied in various fields such as NMR, MRI, and accelerators. We are currently designing a 1.3-GHz LTS/HTS NMR magnet that operates in a persistent current (PC) mode. However, there are issues with using REBCO coils that need to be resolved. One problem unique to REBCO coils is non-uniform electromagnetic forces caused by screening currents. During the charging and discharging of the coil, screening currents are induced, resulting in a significantly non-uniform current distribution within the coil. As a result, non-uniform electromagnetic forces are generated within the coil due to these screening currents. In this study, we performed an electromagnetic stress analysis using a two-dimensional axisymmetric structural analysis that considered tension during winding, thermal stress during cooling, and electromagnetic force during charging. First, we compared the results of the numerical simulation of the layer-wound REBCO coil with the experimental results. Then, we conducted numerical simulations of an insert REBCO coil in a design example of a 1.3-GHz NMR to evaluate the stress and deformation of the REBCO coil.


  • Basic Behavior of the Contact Resistivity of an Intra-Layer No-Insulation (LNI) REBCO Coil

    by Keisuke Takahashi, Yu Suetomi, Tomoaki Takao, Hideaki Maeda, Yoshinori Yanagisawa

    The intra-layer no-insulation (LNI) method is effective for protecting a layer-wound REBCO coil from a quench. The most influential parameter is the electrical contact resistivity ct between the conductors and the copper sheets for current bypassing inside the winding. In previous work, an LNI-REBCO coil was protected from a 31.4 T quench, owing to a high ct value of 10,000 cm2. Thus, achieving the desired ct is of great importance for designing and fabricating an LNI-REBCO coil. In the present work, for obtaining basic knowledge on the behavior of the value of ct, we made a series of experiments; contact model experiment and coil experiment. The comparison between the experimental results in combination with a structural analysis suggests that the ct value of a coil does not follow a general electrical contact theory dominated by surface pressure; it is substantially affected by layer-to-layer contact conditions, resulting in being sensitive to external effects such as thermal cycling. The knowledge obtained in this work suggests that a solution to freeze the contact condition is required to control the value of ct.


  • Performance of Epoxy-Impregnated Intra-Layer No-Insulation (LNI) REBCO Coils at 77 K

    by Taisuke Yoshida, Yu Suetomi, Keisuke Takahashi, Tomoaki Takao, Yoshinori Yanagisawa, Hideaki Maeda, Hiroshi Ueda

    The intra-layer no-insulation (LNI) method is effective for protecting a layer-wound REBCO coil from a quench. However, a recently reported hoop stress modification (both increase and decrease) due to screening currents is a potential problem causing conductor degradation during charging. Epoxy impregnation can suppress the hoop stress modification and in this work, we develop prototypes of epoxy-impregnated LNI-REBCO coils to be charged at 77 K. Degradation of the coil performance due to cooling down can be prevented by mechanically isolating each layer. The coil shows a reasonably short field delay and current bypass-ing behavior, which are major technical benefits of the LNI-REBCO coil. A structural analysis with screening current-induced electromagnetic forces qualitatively suggests that the epoxy-impregnated LNI-REBCO coil can suppress a compressive hoop stress which causes conductor degradation due to buckling. The tensile hoop stress, however, is still very high at the upper and lower ends of each layer, causing fracture of a superconduct-ing layer; i.e. additional reinforcement is required.


  • Open Access

    Hoop Stress Modification, Stress Hysteresis and Degradation of a REBCO Coil Due to the Screening Current Under External Magnetic Field Cycling

    by Shunji Takahashi, Yu Suetomi, Tomoaki Takao, Yoshinori Yanagisawa, Hideaki Maeda, Yasuaki Takeda, Jun-Ichi Shimoyama

    Degradation of a REBCO coil under external magnetic fields is one of the major technical problems in the field of HTS magnet technology. A possible cause of such degradation is an inhomogeneous hoop stress distribution, or hoop stress modification (both increase and decrease), induced by the screening current. In this work, we investigate such a hoop stress modification by a small coil experiment with a strain measurement and a numerical simulation. An experimental result shows a very high stress increase factor of >4.1, defined by the maximum circumferential stress over BzJR stress, and the simulated result is in qualitative agreements. The strain (stress) shows a hysteresis effect corresponding to the screening current behavior. A large hoop stress modification causes not only a hoop stress increase, but also buckling of the conductor, which induces delamination and micro-clacks of the superconducting layer. We also show the stress modification can be reduced by bonding turns with epoxy.


  • Continuous Heating Criteria to Avoid Thermal Runaway of Insulated HTS Coils in High Fields

    by Hiroki Mochida, Yu Suetomi, Tomoaki Takao, Hideaki Maeda, Yoshinori Yanagisawa

    High-field high temperature superconducting (HTS) coils, in particular REBCO coils, tend to show electromagnetic force-induced degradation and premature thermal runaways. Operation of high-field HTS coils is practicable with resistive voltage if cooling power permits. In this light, understanding coil voltage and the corresponding Joule heating power that may give rise to a thermal runaway is essential for stable magnet operation. In this paper, we report investigations of continuous heating criteria for safe operation, Q safe , and the dependence of Q safe on applied field, operating conductor current density, heating length, cooling condition, and number of coil layers using a numerical simulation based on results of model coil experiment. In addition, Q safe values for actual HTS coils were estimated; the results showed that the simulation can predict Q safe values of actual coils.


  • The MIRAI Program and the New Super-High Field NMR Initiative and Its Relevance to the Development of Superconducting Joints in Japan

    by Hideaki Maeda, Jun-Ichi Shimoyama, Yoshinori Yanagisawa, Yoshitaka Ishii, Masaru Tomita

    Magnets using low temperature superconducting (LTS) conductors require liquid helium cooling, yet can only generate a magnetic field < 24 T. For full-fledged commerciali-zation, high temperature superconducting (HTS) conductors are preferred as they can be cooled by liquid nitrogen, enabling electric power transmission lines. Furthermore, they can gen-erate a much higher magnetic field, in excess of 30 T, in liquid helium, which makes them applicable to super-high field NMR. Unfortunately, the short maximum length of a single HTS con-ductor requires many joints, resulting in a difficult manufac-turing process and a complicated operating procedure. Thus, we have commenced the MIRAI Project in 2017, focusing on developing joining technologies for linking HTS. The program has two important research and development directions: (i) Development of superconducting joints for a persistent mode 1.3 GHz (30.5 T) NMR magnet, i.e. The Super-High Field NMR Initiative in Japan. (ii) Development of ultra-low resistance joints between superconducting DC feeder cables, enabling to connect adjacent railway substations that are 2-5 km apart. This paper firstly overviews the MIRAI Project. Secondly, it will describe initial results from investigations on supercon-ducting joints for a persistent mode NMR magnet; preliminary designs of the 1.3 GHz NMR magnet will also be discussed.


  • Design and Development of a Compact 1 GHz (23.5 T)-Class NMR Magnet With Bi-2223 Inner Coils

    by Renzhong Piao, Yasuyuki Miyoshi, Masatoshi Yoshikawa, Kazuyoshi Saito, Mamoru Hamada, Shinji Matsumoto, Hiroto Suematsu, Hiroki Mochida, Tomoaki Takao, Yu Suetomi, et al.

    The design and development for a compact 1 GHz (23.5 T)-class NMR magnet are presented. The magnet uses inner coils wound with Ni alloy-reinforced Bi-2223 conductors in combination with LTS outer coils. The series-connected coils are operated in a power supply-driven mode. The total magnet size is very compact, and is comparable to that of a currently commercialized 600-MHz (14.1 T) NMR magnet. This owes to a high current density operation of the Bi-2223 inner coils, which contribute as much as 53% of the total magnetic field. This paper investigated the following properties of the Bi-2223 inner coils: First, joint resistance under external magnetic fields; second, tensile stress tolerances of the Bi-2223 conductor under bending condition; third, high compressive stress on Bi-2223 coils; fourth, the effect of screening current-induced magnetic field on the field homogeneity and stability; and fifth, the maximum permissible Joule heating to avoid a thermal runaway. Two Bi-2223 inner coils for the magnet were built and tested in liquid nitrogen, which provided important knowledge for the magnet excitation.


  • The Effect of Tip Leakage Vortex on Cavitation Performance in Axial Hydro Turbine

    by Naoki Masuda, Faris Austen, Hideaki Maeda

    From viewpoint of greenhouse gas emission reduction, recently utilization of renewable energy becomes the focus of attention. Among several renewable energy systems, hydro power generation can supply the most stable energy and Torishima has already supplied an axial micro hydro turbine [1]. In general, the low cost system is needed in the case of micro hydro turbine. And one solution is to apply a fixed blade and constant rotation speed type. However the operating range will be narrow because of a cavitation problem. As is well known, there are some kinds of cavitations in the hydro machinery and they cause adverse effects such as vibration, excessive noise, decreasing efficiency and affecting turbine life [2]. Furthermore, these effects are more serious at partial and/or overload condition, so that turbine allowable operating range is limited by them. Therefore, the purpose of this study is to improve the cavitation performance in wider range for satisfying this requirement. In this paper, we focused on the influence of tip leakage vortex cavitation; one of the important phenomena for cavitation performance improvement as described in the references [3–5]. We tried to clarify the influence by both experimental and numerical investigation on the cavitation performance. In CFD (Computational Fluid Dynamics) analysis, tip clearance was applied for whole circumference model of runner and the full cavitation model [6] was used for the unsteady cavitation analysis. The calculation domain included guide vane was used to consider the effect of unsteady interference between runner and guide vane. In the CFD result, the tip leakage vortex cavitation was identified by void ratio and helicity [7] to analyze vortex structure with detail.


  • Open Access

    Mechanism and Suppressive Methods for Screening-current-induced Magnetic Field of REBCO Coils

    by Yoshinori Yanagisawa, Hideaki Maeda

    REBCO conductors were commercialized only recently in 2009 and therefore the magnet technology for REBCO conductors remains undeveloped. The major technological problems for REBCO coils encountered thus far are (a) degradation in the superconducting performance for mechanical reasons, (b) difficulty in protecting the magnet in the case of a super-normal transition of the REBCO coil and (c) the enormous effect of a screening-current-induced magnetic field. In this paper, the basic mechanism of the screening-current-induced magnetic field and effective remedies for suppressing the screening field is investigated through experiments and numerical simulations.