PF1000 High-Energy Plasma Focus Device Operated With Neon as a Copious Soft X-Ray Source
- 24 October 2017
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 45 (11) , 2979-2983
Abstract
The measured current waveforms of PF1000 plasma focus operating in neon are first fitted to the computed currents using the Lee model for the pressures of 0.5 and 0.8 torr. The fitting fixes the model parameters. The code is then run to study and to optimize the soft X-ray yield from (~352 kJ) PF1000 device. The maximum characteristic soft X-ray (H-like and He-like lines) yield of 4.2 kJ is found to occur at the pressure of 0.85 torr, with the pinch duration of 207 ns and with an all-line yield of 4.8 kJ. Maximum compression (corresponding to smallest pinch radius) of 0.585 cm with the duration of 224 ns is obtained at 1 torr with the greatest all-line yield of 7.1 kJ but a lower characteristic soft X-ray yield of 3.2 kJ. Detailed computation results indicate that the maximum compression (minimum pinch radius) at 1 torr is attributed to two mechanisms: thermodynamics specific heat ratio effects and radiative losses.Keywords
This publication has 31 references indexed in Scilit:
- Effects of Power Terms and Thermodynamics on the Contraction of Pinch Radius in Plasma Focus Devices Using the Lee ModelJournal of Fusion Energy, 2016
- Experiments and simulations on the possibility of radiative contraction/collapse in the PF-1000 plasma focusNukleonika, 2016
- Measurement of Radiative Collapse in 2.2 kJ PF: Achieving High Energy Density (HED) Conditions in a Small Plasma FocusJournal of Fusion Energy, 2016
- Conditions for Radiative Cooling and Collapse in the Plasma Focus Illustrated With Numerical Experiments on PF1000IEEE Transactions on Plasma Science, 2015
- Filamentary structure of plasma produced by compression of puffing deuterium by deuterium or neon plasma sheath on plasma-focus dischargePhysics of Plasmas, 2014
- Comprehensive Study of Neon HXR and SXR Emitted from APF Plasma Focus DeviceJournal of Fusion Energy, 2011
- Model Parameters Versus Gas Pressure in Two Different Plasma Focus Devices Operated in Argon and NeonJournal of Fusion Energy, 2011
- The effect of anode shape on neon soft x-ray emissions and current sheath configuration in plasma focus deviceJournal of Physics D: Applied Physics, 2009
- Current sheath curvature correlation with the neon soft x-ray emission from plasma focus devicePlasma Sources Science and Technology, 2005
- Dimensions and lifetime of the plasma focus pinchIEEE Transactions on Plasma Science, 1996