Improved Delineation of Arteries in the Posterior Fossa of the Brain by Model-Based Iterative Reconstruction in Volume-Rendered 3D CT Angiography
Open Access
- 4 January 2013
- journal article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 34 (5) , 971-975
Abstract
BACKGROUND AND PURPOSE: Improved CTA delineation of arteries and unruptured aneurysms is clinically desired in the posterior fossa. We present a novel model-based iterative reconstruction that models system statistics and optics to improve CT image quality. We investigated the utility of MBIR for improving delineation of arteries in the posterior fossa on 3D brain CTA. MATERIALS AND METHODS: Using filtered back-projection with a standard kernel and MBIR, we reconstructed axial images of 0.625-mm thickness of 28 consecutive patients (14 men; mean age, 58.6 ± 14.6 years) who underwent 64-detector brain CTA. We placed regions of interest on the axial images, measured the mean CT value in the basilar artery and the value and SD in the pons and bilateral cerebellar hemispheres, and calculated the contrast-to-noise ratio of the brain arteries in the posterior fossa. Using volume-rendered CTA and a 4-point scale, 2 radiologists independently graded delineation of the BA, bilateral vertebral artery, superior cerebellar artery, and anterior and posterior inferior cerebellar arteries. We compared the results between FBP and MBIR by using paired t and Wilcoxon signed-rank tests. RESULTS: Compared with FBP, MBIR significantly improved the contrast-to-noise ratio (P < .0001) and subjective delineation of all arteries in the posterior fossa except the BA (VA, SCA, AICA, and PICA; P < .05 for all). The mean visual score by MBIR was 3.0 or higher for all those arteries except the AICA assessed by reader 1 (2.6 ± 0.7). CONCLUSIONS: With 3D brain CTA, contrast-to-noise ratio and arterial delineation of the VA, SCA, AICA, and PICA in the posterior fossa are better with MBIR than FBP.Keywords
This publication has 26 references indexed in Scilit:
- Unruptured Intracranial AneurysmsStroke, 2009
- A three‐dimensional statistical approach to improved image quality for multislice helical CTMedical Physics, 2007
- Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatmentThe Lancet, 2003
- Volume-rendered helical computerized tomography angiography in the detection and characterization of intracranial aneurysmsJournal of Neurosurgery, 2000
- The usefulness of 3D-CT angiography for the diagnosis of spontaneous vertebral artery dissection—report of two casesComputerized Medical Imaging and Graphics, 2000
- Use of spiral computerized tomography angiography in patients with subarachnoid hemorrhage in whom subtraction angiography did not reveal cerebral aneurysmsJournal of Neurosurgery, 2000
- Intracranial Aneurysms: Detection with Three-dimensional CT Angiography with Volume Rendering—Comparison with Conventional Angiographic and Surgical FindingsRadiology, 1999
- Subarachnoid hemorrhage: aneurysm detection and preoperative evaluation with CT angiography.Radiology, 1998
- Detection of circle of Willis aneurysms in patients with acute subarachnoid hemorrhage: a comparison of CT angiography and digital subtraction angiography.American Journal of Roentgenology, 1995
- Evaluation of cerebral aneurysms with helical CT: correlation with conventional angiography and MR angiography.Radiology, 1994