Conversion factor for size specific dose estimation of head CT scans based on age, for individuals from 0 up to 18 years old
- 16 April 2021
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (8) , 085011
Abstract
Assessing the radiation doses received by patients in computed tomography is still challenging. To overcome this, the American Association of Physicists in Medicine has introduced the concept of the size specific dose estimate (SSDE). However, the calculation of SSDE for head CT scans requires the knowledge of attenuation characteristics of the volume scanned, making its implementation in the daily clinical workflow cumbersome. In this study, we defined conversion coefficients from CTDI vol,16cm to SSDE for head CT scans based solely on the age of the patient. Using the head circumference-for-age from the child growth standards of the World Health Organization (WHO), the effective diameter-for-age was calculated for male and female individuals from 0 to 60 months-old. The effective diameter was converted into a water equivalent diameter-for-age, using a correlation established from the measurements of both quantities in 295 exams of male and female patients, from 0 to 18 years-old. WHO-estimated water equivalent diameter-for-age was validated against the measured water equivalent diameter-for-age. The head circumference-for-age from WHO was extrapolated for male and females individuals up to 18 years-old and their respective water equivalent diameter were estimated. Finally, the SSDE was calculated for all the CT head scans performed in a 9-years period in patients aged from 0 to 18 years old. Typical values of CTDI vol,16cm and DLP were also defined. SSDE varied from 0.80 up to 1.16 of the CTDI vol,16cm , depending on sex and age of the patient. WHO-estimated water equivalent diameter-for-age differed less than 20% from the measured water equivalent diameter-for-age. Typical values of SSDE varied from 28.5 up to 38.9 mGy, while typical values ranged from 30.9 up to 47.6 mGy for the CTDI vol,16cm and from 417.6 up to 861.1 mGy*cm for the DLP. SSDE can be directly calculated for head CT scans once the age of the patient is known.Keywords
Funding Information
- Conselho Nacional de Desenvolvimento Científico e Tecnológico (156056/2018-6)
- FAPESP--Neuromat (2013/07699-0)
This publication has 11 references indexed in Scilit:
- LOCAL DRLS FOR PAEDIATRIC CT EXAMINATIONS BASED ON SIZE-SPECIFIC DOSE ESTIMATES IN KERMANSHAH, IRANRadiation Protection Dosimetry, 2019
- Correlation of size-dependent conversion factor and body-mass-index using size-specific dose estimates formalism in CT examinationsEuropean Journal of Radiology, 2018
- Evaluation of AAPM Reports 204 and 220: Estimation of effective diameter, water‐equivalent diameter, and ellipticity ratios for chest, abdomen, pelvis, and head CT scansJournal of Applied Clinical Medical Physics, 2017
- U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT ExaminationsRadiology, 2017
- The Use of Computed Tomography in Pediatrics and the Associated Radiation Exposure and Estimated Cancer RiskJAMA Pediatrics, 2013
- Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort studyThe Lancet, 2012
- Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations2011
- Patient Size Measured on CT Images as a Function of Age at a Tertiary Care Children's HospitalAmerican Journal of Roentgenology, 2010
- United States Head Circumference Growth Reference Charts: Birth to 21 YearsThe Journal of Pediatrics, 2010
- Imaging strategies to reduce the risk of radiation in CT studies, including selective substitution with MRIJournal of Magnetic Resonance Imaging, 2007