  • Occupational dose attenuation and dosimetric performance of autonomous radiation protection systems in fluoroscopy: a scoping review with implications for the role of conventional lead aprons

    by Sergio Ramos-Avasola, Nitza Espinosa-Rojo, Ricardo Ampuero, Constanza Vira, Mario Araya, Adlin López Díaz, E Honorio da Silva

    Background: Interventional cardiology procedures chronically expose healthcare personnel to ionizing radiation, raising concerns about long-term health effects such as cataracts and cancer. Consequently, growing attention has been directed toward advanced shielding technologies capable of substantially reducing occupational dose while improving ergonomic conditions.” Objective: To synthesize the available evidence on the technical performance and radiation attenuation capabilities of Autonomous Radiation Protection Systems (Protego™, Rampart™, and EggNest XR™), used in interventional cardiology settings. Methods: A scoping review was conducted following the PRISMA-ScR framework. Relevant studies were identified through a systematic search of PubMed, EBSCO, Scopus, WOS and Cochrane. Eligible studies included clinical and phantom-based assessments reporting quantitative dosimetric outcomes. Results: Fourteen studies met the inclusion criteria. Protego™ was associated with consistently high reported attenuation, typically ≥95% in studies providing quantifiable measurements; in several investigations, post-shielding doses fell below the detection limits of standard personal dosimeters, whereas Rampart™ demonstrated wider reported attenuation ranges (approximately 16.7–100%) across heterogeneous study designs and measurement protocols and EggNest XR™ exhibited attenuation values ranging from 91.5% to 99.0% in a single phantom-based study. Device performance varied by anatomical site and professional role, with higher attenuation typically observed among primary operators (often exceeding 95% at head and torso levels) compared with more variable reductions in peripheral personnel such as nurses and anesthesiologists, where attenuation occasionally decreased to the 80–90% range depending on positioning and projection. Conclusion: The attenuation results for autonomous shielding systems are promising, particularly for fixed systems, which demonstrate consistently high performance. Given their potential for ergonomic improvement and radiation reduction, Autonomous Radiation Protection Systems (ARPS) are emerging as valuable tools. However, given the limited clinical validation and the heterogeneity of existing study, the implementation of these systems should be supported by site-specific validation and standardized dosimetry protocols.”

  • Changes induced in the human respiratory tract by chronic cigarette smoking can reduce the dose to the lungs from exposure to radon progeny

    by E Honorio da Silva, E Davesne, Y Bonchuk, G Ratia, B Madas, V Berkovskyy, D Broggio

    Chronic cigarette smoking leads to changes in the respiratory tract that might affect the dose received from exposure to radon progeny. In this study, changes induced by cigarette smoking in the respiratory tract were collected from the literature and used for calculation of the dose received by the lungs and organs outside the respiratory tract. Morphological and physiological parameters affected by chronic smoking were implemented in the human respiratory tract model (HRTM) used by the International Commission of Radiological Protection (ICRP). Smokers were found to receive lung doses 3% smaller than the ICRP reference worker (non-smoking reference adult male) in mines and 14% smaller in indoor workplaces and tourist caves. A similar dose reduction was found for the extrathoracic region of the HRTM. Conversely, kidneys, brain, and bone marrow of smokers were found to receive from 2.3- up to 3-fold of the dose received by the respective organ in the ICRP reference worker, although they remained at least two orders of magnitude smaller than the lung dose. These results indicate that the differences in the lung dose from radon progeny exposure in cigarette smokers and non-smokers are smaller than 15%.


  • An investigation into potential improvements in the design of lead glasses for protecting the eyes of interventional cardiologists

    by Edilaine Honorio da Silva, Colin J Martin, Filip Vanhavere, Jérémie Dabin, Nico Buls

    The lens of the eye can be damaged by ionising radiation, so individuals whose eyes are exposed to radiation during their work may need to protect their eyes from exposure. Lead glasses are widely available, but there are questions about their efficiency in providing eye protection. In this study, Monte Carlo simulations are used to assess the efficiency of lead glasses in protecting the sensitive volume of the eye lens. Two designs currently available for interventional cardiologists are a wraparound (WA) style and ones with flat frontal lenses with side shielding. These designs were considered together with four modifications that would impact upon their efficiency: changing the lead equivalent thickness, adding lead to the frames, elongating the frontal lenses, and adding a closing shield to the bottom rim. For the eye closest to the source, standard models of lead glasses only decrease the radiation reaching the most sensitive region of the eye lens by 22% or less. Varying the lead thickness between 0.4 mm and 0.75 mm had little influence on the protection provided in the simulation of clinical use, neither did adding lead to the frames. Improved shielding was obtained by elongating the frontal lens, which could reduce radiation reaching the eye lens by up to 76%. Glasses with lenses that had a rim at the base, extending towards the face of the user, also provided better shielding than current models, decreasing the dose by up to 80%. In conclusion, elongating the frontal lens of lead glasses, especially of the WA design, could provide a three-fold increase in shielding efficiency and this is still valid for lenses with 0.4 mm lead equivalence.


  • Conversion factor for size specific dose estimation of head CT scans based on age, for individuals from 0 up to 18 years old

    by Edilaine Honorio da Silva, Oswaldo Baffa, Jorge Elias, Nico Buls

    Assessing the radiation doses received by patients in computed tomography is still challenging. To overcome this, the American Association of Physicists in Medicine has introduced the concept of the size specific dose estimate (SSDE). However, the calculation of SSDE for head CT scans requires the knowledge of attenuation characteristics of the volume scanned, making its implementation in the daily clinical workflow cumbersome. In this study, we defined conversion coefficients from CTDI vol,16cm to SSDE for head CT scans based solely on the age of the patient. Using the head circumference-for-age from the child growth standards of the World Health Organization (WHO), the effective diameter-for-age was calculated for male and female individuals from 0 to 60 months-old. The effective diameter was converted into a water equivalent diameter-for-age, using a correlation established from the measurements of both quantities in 295 exams of male and female patients, from 0 to 18 years-old. WHO-estimated water equivalent diameter-for-age was validated against the measured water equivalent diameter-for-age. The head circumference-for-age from WHO was extrapolated for male and females individuals up to 18 years-old and their respective water equivalent diameter were estimated. Finally, the SSDE was calculated for all the CT head scans performed in a 9-years period in patients aged from 0 to 18 years old. Typical values of CTDI vol,16cm and DLP were also defined. SSDE varied from 0.80 up to 1.16 of the CTDI vol,16cm , depending on sex and age of the patient. WHO-estimated water equivalent diameter-for-age differed less than 20% from the measured water equivalent diameter-for-age. Typical values of SSDE varied from 28.5 up to 38.9 mGy, while typical values ranged from 30.9 up to 47.6 mGy for the CTDI vol,16cm and from 417.6 up to 861.1 mGy*cm for the DLP. SSDE can be directly calculated for head CT scans once the age of the patient is known.


  • A study of the underestimation of eye lens dose with current eye dosemeters for interventional clinicians wearing lead glasses

    by Edilaine Honorio da Silva, Colin John Martin, Filip Vanhavere, Nico Buls

    The reduction in the occupational dose limit of the eye lens has created the need for optimising eye protection and dose assessment, in particular for interventional clinicians. Lead glasses are one of the protection tools for shielding the eyes, but assessing the eye lens dose when these are in place remains challenging. In this study, we evaluated the impact of the position of H p (3) dosemeters on the estimated eye lens dose when lead glasses are used in interventional settings. Using the Monte Carlo method (MCNPX), an interventional cardiology setup was simulated for two models of lead glasses, five beam projections and two patient access routes. H p (3) dosemeters were placed at several positions on the operator and the obtained dose was compared to the dose to the sensitive part of the eye lens ( H lens ). Furthermore, to reproduce an experimental setup, a reference dosemeter, H p (3) ref , was placed on the surface of the eye. The dose measured by H p (3) ref was, on average, only 60% of H lens . Dosemeters placed on the glasses, under their shielding, underestimated H lens for all parameters considered, by from 10% up to 90%. Conversely, dosemeters placed on the head or on the glasses, over their shielding, overestimated H lens , on average, up to 60%. The presence or lack of side shielding in lead glasses affected mostly dosemeters placed on the forehead, at the left side. Results suggest that both use of a correction factor of 0.5 to account for the presence of lead glasses in doses measured outside their shielding and placing an eye lens dosemeter immediately beneath the lenses of lead glasses may lead to the underestimation of the eye lens dose. Most suitable positions for eye lens dose assessment were on the skin, unshielded by the glasses or close to the eye, with no correction to the dose measured.


  • OPTIMIZATION OF A RADIOPHOTOLUMINESCENT GLASS DOSEMETER FOR OCCUPATIONAL EYE LENS DOSIMETRY IN INTERVENTIONAL RADIOLOGY/CARDIOLOGY

    by Edilaine H Silva, Lara Struelens, Peter Covens, Satoshi Ueno, Yasuhiro Koguchi, Filip Vanhavere, Nico Buls

    Hospital based workers that perform interventional radiology are at risk of reaching the eye lens dose limit of 20 mSv/y. These workers are exposed to the radiation scattered by the patient, which creates a complex field, with low radiation energy reaching the eyes of the medical staff from wide angles. Therefore, the dosemeter used in the assessment of the eye lens dose of interventional radiologists needs to respond accurately in such conditions. In this study, the angular response of a commercially available radiophotoluminescent glass dosemeter, GD-352M, was optimized via Monte Carlo simulations, aiming at its use as eye lens dosemeter in interventional radiology. The improved dosemeter was manufactured and then characterized in terms of Hp(3), the quantity recommended for eye lens dosimetry. Its response was compared to the IEC 62387:2012 requirements for Hp(3) and to requirements proposed specifically for eye lens dosemeters used in interventional radiology. The improved dosemeter meets the IEC 62387:2012 requirements for energy and angular response for Hp(3) and also shows good agreement with the more strict requisites proposed for eye lens dosemeters to be used in interventional radiology.


  • Effect of protective devices on the radiation dose received by the brains of interventional cardiologists

    by Edilaine Honorio da Silva, Filip Vanhavere, Lara Struelens, Peter Covens, Nico Buls

    This study aimed to evaluate the effectiveness of ceiling suspended screens, lead glasses and lead caps in reducing radiation doses to the brains of interventional cardiologists. Interventional procedures where the thorax of the patient is irradiated with different beam projections were modelled. The dose reduction in the white matter and hippocampus of the Zubal head phantom was studied for two sizes of ceiling suspended screens, two types of lead glasses and lead caps of surgical and hood models, which cover different regions of the head. Ceiling screens were the most effective, reducing the dose to brain tissue by 74% or even as much as 94%. The dose reduction provided by lead glasses varies between 10% and 17%. For the lead caps, it strongly depends on the model, varying from 6% (surgical) up to 68% (hood that also covered lower parts of the head). The dose to the brain can be reduced by using appropriate radiation protection devices. This study has shown that lead caps are less protective than previously described and that the best protection is given by ceiling suspended screens, which are widely available in interventional theatres.


  • Where is the best position to place a dosemeter in order to assess the eye lens dose when lead glasses are used?

    by Edilaine Honorio da Silva, Lara Struelens, Peter Covens, Satoshi Ueno, Michiko Ube, Filip Vanhavere, Nico Buls


  • Open Access

    Wear and Corrosion Study of Plasma Nitriding F53 Super duplex Stainless Steel

    by Joaquim Olímpio Pereira Neto, Raphael Oliveira da Silva, Edilaine Honório da Silva, Jeferson Aparecido Moreto, Rafael Marinho Bandeira, Marcos Dorigão Manfrinato, Luciana Sgarbi Rossino

    Super duplex stainless steels (SDSS) have high corrosion resistance because of their high contents of chromium, nickel, molybdenum and nitrogen but low wear resistance. To improve the wear resistance of these steels without affecting their corrosion resistance, samples of SDSS were treated by plasma ion nitriding at temperatures ranging from 350 °C to 570 °C for two hours. This thermochemical treatment resulted in the formation of different types of nitrides that affected the microhardness, the microwear behaviour and the corrosion resistance of the metal surface. The microwear resistance decreased at 400 °C because different nitrides formed on the surface, thereby increasing the hardness and volume wear resistance of the steel. The test results showed that the alloys that were nitrided at 400 °C and 450 °C exhibited the highest corrosion resistance to a solution medium containing chloride ions.


  • ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY

    by E. H. Silva, Ž. Knežević, L. Struelens, P. Covens, S. Ueno, F. Vanhavere, N. Buls

    Recent studies demonstrated that lens opacities can occur at lower radiation doses than previously accepted. In view of these studies, the International Commission of Radiological Protection recommended in 2011 to reduce the eye lens dose limit from 150 mSv/y to 20 mSv/y. This implies in the need of monitoring doses received by the eye lenses. In this study, small rod radiophotoluminescent glass dosemeters (GD-300 series; AGC, Japan) were characterized in terms of their energy (ISO 4037 X-rays narrow spectrum series, S-Cs and S-Co) and angular dependence (0 up to 90 degrees, with 2 ISO energies: N-60 and S-Cs). All acquisitions were performed at SCK•CEN—Belgium, using the ORAMED proposed cylindrical phantom. For selected energies (N-60, N-80, N-100, N-120 and N-250), the response of dosemeters irradiated on the ISO water slab phantom, at the Ruđer Bošković Institute—Croatia, was compared to those irradiated on the cylindrical phantom. GD-300 series showed good energy dependence, relative to S-Cs, on the cylindrical phantom. From 0 up to 45 degrees, the dosemeters showed no significant angular dependence, regardless whether they were tested when placed vertically or horizontally on the cylindrical phantom. However, at higher angles, some angular dependence was observed, mainly when the dosemeters were irradiated with low-energy photons (N-60). Results showed that GD-300 series have good properties related to Hp(3), although some improvements may be necessary.