Purpose: the aim of the computational 3D-finite element study is to evaluate the influence of an augmented sinus lift with additional inserted bone grafting. The bone graft block stabilizes the implant in conjunction with conventional bone augmentation. Two finite element models were applied: the real geometry based bone models and the simplified geometry models. The bone graft block was placed in three different positions. The implants were loaded first with an axial force and then with forces simulating laterotrusion and protrusion. This study examines whether the calculated stress behavior is symmetrical for both models. Having established a symmetry between the primary axis, the laterotrusion and protrusion behavior reduces calculation efforts, by simplifying the model. Material and Methods: a simplified U-shaped 3D finite element model of the molar region of the upper jaw and a more complex anatomical model of the left maxilla with less cortical bone were created. The bone graft block was placed in the maxillary sinus. Then the von Mises stress distribution was calculated and analyzed at three block positions: at contact with the sinus floor, in the middle of the implant helix and in the upper third of the implant. The two finite element models were then compared to simplify the modelling. Results: the position of the bone graft block significantly influences the magnitude of stress distribution. A bone graft block positioned in the upper third or middle of the implant reduces the quantity of stress compared to the reference model without a bone graft block. The low bone graft block position is clearly associated with lower stress distribution in compact bone. We registered no significant differences in stress in compact bone with regard to laterotrusion or protrusion. Conclusions: maximum values of von Mises stresses in compact bone can be reduced significantly by using a bone graft block. The reduction of stress is nearly the same for positions in the upper third and the middle of the implant. It is much more pronounced when the bone graft block is in the lower third of the implant near the sinus floor, which appeared to be the best position in the present study.Keywords
All Related Versions
This publication has 24 references indexed in Scilit:
- Analysis of the biomechanical feasibility of a wide implant in moderately atrophic maxillary sinus region with finite element methodOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2012
- Influence of maxillary cortical bone thickness, implant design and implant diameter on stress around implants: A three-dimensional finite element analysisJournal of Prosthodontic Research, 2010
- Implant–Bone Interface Stress Distribution in Immediately Loaded Implants of Different Diameters: A Three‐Dimensional Finite Element AnalysisJournal of Prosthodontics, 2009
- Factorial analysis of variables influencing mechanical characteristics of a single tooth implant placed in the maxilla using finite element analysis and the statistics‐based Taguchi methodEuropean Journal of Oral Sciences, 2007
- Artificial composite bone as a model of human trabecular bone: The implant–bone interfaceJournal of Biomechanics, 2007
- Material properties of the dentate maxillaThe Anatomical Record Part A: Discoveries in Molecular, Cellular, and Evolutionary Biology, 2006
- Application of the finite element method in dental implant researchComputer Methods in Biomechanics and Biomedical Engineering, 2006
- Implant Biomechanics in Grafted Sinus: A Finite Element AnalysisJournal of Oral Implantology, 2004
- 2D-finite element analyses and histomorphology of lag screws with and without a biconcave washerJournal of Biomechanics, 1999
- Proposal for the regulatory mechanism of Wolff's lawJournal of Orthopaedic Research, 1995