KEKarl Entacher

Karl Entacher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Karl Entacher has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Temporary Protective Shoulder Implants for Revision Surgery with Bone Glenoid Grafting

    by Daniel Schaffarzick, Karl Entacher, Dietmar Rafolt, Peter Schuller-Götzburg

    This article describes the development of a temporary protective glenoid prosthesis placed between the augmentation and humeral head prosthesis during the healing phase of shoulder prosthesis revision with necessary reconstruction of the bony structure of the glenoid. The glenoid protection prosthesis ensures the fixation of the augmentation material and protects the screws from contact with the metallic humeral head prosthesis. Another approach of the development is a reduction of the resorption of the augmentation by targeted mechanical stimulation of the tissue. The aim should be to achieve significantly improved conditions for the implantation of a new glenoid component at the end of the healing phase of the augmentation material in comparison to the current standard method. The development of the protective prosthesis was carried out according to specific needs and includes the collection of requirements and boundary conditions, the design and technical detailing of the implant, the verification of the development results as well as the validation of the design. For the verification, FEM simulations (Finite Element Analysis) were performed to estimate the mechanical stability in advance. Mechanical tests to confirm the stability and abrasion behavior have been carried out and confirm the suitability of the protective implant. The result of the present work is the detailed technical design of two variants of a glenoid protective prosthesis “GlenoProtect” for use in revision procedures on shoulder joints—with large-volume defects on the glenoid—treated by arthroplasty and the necessity of augmenting the glenoid, including a description of the surgical procedure for implantation.


  • Open Access

    Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block

    by Peter Schuller-Götzburg, Thomas Forte, Werner Pomwenger, Alexander Petutschnigg, Franz Watzinger, Karl Entacher

    Purpose: the aim of the computational 3D-finite element study is to evaluate the influence of an augmented sinus lift with additional inserted bone grafting. The bone graft block stabilizes the implant in conjunction with conventional bone augmentation. Two finite element models were applied: the real geometry based bone models and the simplified geometry models. The bone graft block was placed in three different positions. The implants were loaded first with an axial force and then with forces simulating laterotrusion and protrusion. This study examines whether the calculated stress behavior is symmetrical for both models. Having established a symmetry between the primary axis, the laterotrusion and protrusion behavior reduces calculation efforts, by simplifying the model. Material and Methods: a simplified U-shaped 3D finite element model of the molar region of the upper jaw and a more complex anatomical model of the left maxilla with less cortical bone were created. The bone graft block was placed in the maxillary sinus. Then the von Mises stress distribution was calculated and analyzed at three block positions: at contact with the sinus floor, in the middle of the implant helix and in the upper third of the implant. The two finite element models were then compared to simplify the modelling. Results: the position of the bone graft block significantly influences the magnitude of stress distribution. A bone graft block positioned in the upper third or middle of the implant reduces the quantity of stress compared to the reference model without a bone graft block. The low bone graft block position is clearly associated with lower stress distribution in compact bone. We registered no significant differences in stress in compact bone with regard to laterotrusion or protrusion. Conclusions: maximum values of von Mises stresses in compact bone can be reduced significantly by using a bone graft block. The reduction of stress is nearly the same for positions in the upper third and the middle of the implant. It is much more pronounced when the bone graft block is in the lower third of the implant near the sinus floor, which appeared to be the best position in the present study.


  • Open Access

    A Bone Sample Containing a Bone Graft Substitute Analyzed by Correlating Density Information Obtained by X-ray Micro Tomography with Compositional Information Obtained by Raman Microscopy

    by Johann Charwat-Pessler, Maurizio Musso, Alexander Petutschnigg, Karl Entacher, Bernhard Plank, Erik Wernersson, Stefan Tangl, Peter Schuller-Götzburg

    The ability of bone graft substitutes to promote new bone formation has been increasingly used in the medical field to repair skeletal defects or to replace missing bone in a broad range of applications in dentistry and orthopedics. A common way to assess such materials is via micro computed tomography (µ-CT), through the density information content provided by the absorption of X-rays. Information on the chemical composition of a material can be obtained via Raman spectroscopy. By investigating a bone sample from miniature pigs containing the bone graft substitute Bio Oss®, we pursued the target of assessing to what extent the density information gained by µ-CT imaging matches the chemical information content provided by Raman spectroscopic imaging. Raman images and Raman correlation maps of the investigated sample were used in order to generate a Raman based segmented image by means of an agglomerative, hierarchical cluster analysis. The resulting segments, showing chemically related areas, were subsequently compared with the µ-CT image by means of a one-way ANOVA. We found out that to a certain extent typical gray-level values (and the related histograms) in the µ-CT image can be reliably related to specific segments within the image resulting from the cluster analysis.


  • Normalization of the Spectral Test in High Dimensions

    by Karl Entacher, Gerold Laimer, Harald Röck, Andreas Uhl

    The spectral test provides a reliable measure for lattice assessment and can be computed very efficiently. It has extensively been applied to find good lattices for several MC and QMC applications. In order to enable comparisons across dimensions, a normalized spectral test is widely used. We empirically demonstrate significant shortcomings of this normalization in high dimensions, discuss the empirical distribution of the normalized spectral test values, and propose a new normalization strategy. The new normalization is shown to give more reliable results, especially concerning the comparability of the values accross dimensions.