Membrane-Based Portable Colorimetric Gaseous Chlorine Sensing Probe
- 15 December 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (2) , 769-776
Abstract
Highly toxic chlorine gas imposes serious health risks in the workplace. The ability to on-site, real-time monitoring of instantaneous and time-weighted average (TWA) chlorine gas concentrations in a simple, sensitive, accurate, and reliable manner would be highly beneficial to improve workplace health and safety. Here, we propose and experimentally validate a gaseous chlorine detection principle based on a N,N-diethyl-p-phenylenediamine sulfate salt/Cl2 colorimetric reaction-controlled membrane process to regulate the gaseous chlorine transport across a gas-permeable membrane that enables the establishment of a time-resolved analytical relationship to quantify chlorine concentration by multidata points with dramatically enhanced accuracy and reliability. A gas-permeable membrane-based portable colorimetric gaseous chlorine sensing probe (MCSP) was designed and fabricated. The MCSP embedded the proposed analytical principle that is capable of real-time continuous monitoring of the instantaneous and TWA chlorine gas concentrations within an analytical range of 0.009–2.058 mg L–1 without the need for on-going calibration, which could be a useful analytical tool for managing the toxic chlorine gas-imposed health risks in workplaces.Keywords
Funding Information
- Australian Research Council
- Griffith University
- National Natural Science Foundation of China (21806080)
This publication has 41 references indexed in Scilit:
- Civilian exposure to chlorine gas: A systematic reviewToxicology Letters, 2018
- Fatal chlorine gas exposure at a metal recycling facility: Case reportAmerican Journal of Industrial Medicine, 2018
- Selective detection of chlorine at room temperature utilizing single-walled carbon nanotubes functionalized with platinum nanoparticles synthesized via ultraviolet irradiationSensors and Actuators B: Chemical, 2017
- Persistent effects of chlorine inhalation on respiratory healthAnnals of the New York Academy of Sciences, 2016
- Low-Cost Graphite-Based Free Chlorine SensorAnalytical Chemistry, 2015
- Two-dimensional fuzzy fault tree analysis for chlorine release from a chlor-alkali industry using expert elicitationJournal of Hazardous Materials, 2010
- Chlorine Gas Inhalation: Human Clinical Evidence of Toxicity and Experience in Animal ModelsProceedings of the American Thoracic Society, 2010
- The Toxicology of ChlorineEnvironmental Research, 2001
- Room Temperature Operating Solid‐State Sensor for Chlorine GasJournal of the Electrochemical Society, 1998
- Potentiometric chlorine gas sensor using BaCl2-KCl solid electrolyte: The influences of barium oxide contaminationSensors and Actuators B: Chemical, 1997