Tianling Li
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tianling Li has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Huijun Zhao
Key Laboratory of Materials Physics Centre For Resource Innovation Anhui Key Laboratory of Nanomaterials and Nanotechnology Institute of Solid State Physics HFIPS Chinese Academy of Sciences Hefei China
4 shared publications - Ming Zhou
School of Environment and Science, Gold Coast Campus, Griffith University, Gold Coast, QLD 4222, Australia
4 shared publications - Jianyin Huang
The University of Queensland, School of Agriculture and Food Sustainability, St Lucia, Queensland, 4072, Australia; Adelaide University, School of Physics, Chemistry and Earth Sciences, Mawson Lakes Campus, Mawson Lakes, South Australia, 5095, Australia
3 shared publications - Shanqing Zhang
Institute for Sustainable Transformation School of Chemical Engineering and Light Industry Guangdong University of Technology Guangzhou China
3 shared publications - Chenxu Wang
Collaborative Innovation Centre of Atmospheric Environment and Equipment Technology, Jiangsu Key Laboratory of Atmospheric Environment Monitoring and Pollution Control, School of Environmental Science and Engineering, Nanjing University of Information Science & Technology, Nanjing, Jiangsu, 210044, PR China
2 shared publications Ming Zhou
2 shared publications
Latest Publications
- 3 March 2026
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 6 (3) , 1752-1764
Validation of Colorimetric 2D DET Techniques for Concurrent Measurement of Ammonium and Nitrate/Nitrite in Sediment Porewater
- 3 March 2026
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 6 (3) , 1752-1764
Validation of Colorimetric 2D DET Techniques for Concurrent Measurement of Ammonium and Nitrate/Nitrite in Sediment Porewater
- Open Access
- 17 October 2023
- Published by Elsevier in Journal of Cleaner Production
- Vol. 428
Cutting-edge ammonia emissions monitoring technology for sustainable livestock and poultry breeding: A comprehensive review of the state of the art
- 17 October 2023
- Published by Elsevier in Journal of Cleaner Production
- Vol. 428
Open AccessCutting-edge ammonia emissions monitoring technology for sustainable livestock and poultry breeding: A comprehensive review of the state of the art
- 2 October 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (10) , 3836-3844
Portable Conductometric Sensing Probe for Real-Time Monitoring Ammonia Profile in Coastal Waters
An ability to real-time and continuously monitor ammonium/ammonia profiles of coastal waters over a prolonged period in a simple and maintenance-free fashion would enable economic conducting large-scale assessments, providing the needed scientific insights to better control and mitigate the impact of eutrophication on coastal ecosystems. However, this is a challenging task due to the lack of capable sensors. Here, we demonstrate the use of a membrane-based conductometric ammonia sensing probe (CASP) for real-time monitoring of ammonia levels in coastal waters. A boric acid/glycerol receiving phase is investigated and innovatively utilized to overcome the high salinity of coastal water-induced analytical errors. A calibration-free approach is used to eliminate the need for ongoing calibration, while the issues concerning practical applications, such as salinity variation, ammonia intake capability, and biofouling, are systematically investigated. The field deployment at an estuary confluence water site over a half-moon cycle period confirms that CASP is capable of continuously monitoring the ammonia profile of coastal waters in real-time with high resolution and accuracy to unveil the dynamic ammonia concentration changes over a prolonged period.
- 2 October 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (10) , 3836-3844
Portable Conductometric Sensing Probe for Real-Time Monitoring Ammonia Profile in Coastal Waters
An ability to real-time and continuously monitor ammonium/ammonia profiles of coastal waters over a prolonged period in a simple and maintenance-free fashion would enable economic conducting large-scale assessments, providing the needed scientific insights to better control and mitigate the impact of eutrophication on coastal ecosystems. However, this is a challenging task due to the lack of capable sensors. Here, we demonstrate the use of a membrane-based conductometric ammonia sensing probe (CASP) for real-time monitoring of ammonia levels in coastal waters. A boric acid/glycerol receiving phase is investigated and innovatively utilized to overcome the high salinity of coastal water-induced analytical errors. A calibration-free approach is used to eliminate the need for ongoing calibration, while the issues concerning practical applications, such as salinity variation, ammonia intake capability, and biofouling, are systematically investigated. The field deployment at an estuary confluence water site over a half-moon cycle period confirms that CASP is capable of continuously monitoring the ammonia profile of coastal waters in real-time with high resolution and accuracy to unveil the dynamic ammonia concentration changes over a prolonged period.
- 8 February 2023
- Published by Elsevier
- p. 101-135
Environmental monitoring and membrane technologies: a possible marriage?
- 8 February 2023
- Published by Elsevier
- p. 101-135
Environmental monitoring and membrane technologies: a possible marriage?
- 13 May 2022
- Published by Elsevier in Chemosphere
- Vol. 303 (Pt 1) , 134944
Ammonia volatilization mitigation in crop farming: A review of fertilizer amendment technologies and mechanisms
- 13 May 2022
- Published by Elsevier in Chemosphere
- Vol. 303 (Pt 1) , 134944
Ammonia volatilization mitigation in crop farming: A review of fertilizer amendment technologies and mechanisms
- 15 December 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (2) , 769-776
Membrane-Based Portable Colorimetric Gaseous Chlorine Sensing Probe
Highly toxic chlorine gas imposes serious health risks in the workplace. The ability to on-site, real-time monitoring of instantaneous and time-weighted average (TWA) chlorine gas concentrations in a simple, sensitive, accurate, and reliable manner would be highly beneficial to improve workplace health and safety. Here, we propose and experimentally validate a gaseous chlorine detection principle based on a N,N-diethyl-p-phenylenediamine sulfate salt/Cl2 colorimetric reaction-controlled membrane process to regulate the gaseous chlorine transport across a gas-permeable membrane that enables the establishment of a time-resolved analytical relationship to quantify chlorine concentration by multidata points with dramatically enhanced accuracy and reliability. A gas-permeable membrane-based portable colorimetric gaseous chlorine sensing probe (MCSP) was designed and fabricated. The MCSP embedded the proposed analytical principle that is capable of real-time continuous monitoring of the instantaneous and TWA chlorine gas concentrations within an analytical range of 0.009–2.058 mg L–1 without the need for on-going calibration, which could be a useful analytical tool for managing the toxic chlorine gas-imposed health risks in workplaces.
- 15 December 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (2) , 769-776
Membrane-Based Portable Colorimetric Gaseous Chlorine Sensing Probe
Highly toxic chlorine gas imposes serious health risks in the workplace. The ability to on-site, real-time monitoring of instantaneous and time-weighted average (TWA) chlorine gas concentrations in a simple, sensitive, accurate, and reliable manner would be highly beneficial to improve workplace health and safety. Here, we propose and experimentally validate a gaseous chlorine detection principle based on a N,N-diethyl-p-phenylenediamine sulfate salt/Cl2 colorimetric reaction-controlled membrane process to regulate the gaseous chlorine transport across a gas-permeable membrane that enables the establishment of a time-resolved analytical relationship to quantify chlorine concentration by multidata points with dramatically enhanced accuracy and reliability. A gas-permeable membrane-based portable colorimetric gaseous chlorine sensing probe (MCSP) was designed and fabricated. The MCSP embedded the proposed analytical principle that is capable of real-time continuous monitoring of the instantaneous and TWA chlorine gas concentrations within an analytical range of 0.009–2.058 mg L–1 without the need for on-going calibration, which could be a useful analytical tool for managing the toxic chlorine gas-imposed health risks in workplaces.
- 7 June 2019
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 4 (7) , 1881-1888
Online Conductimetric Flow-Through Analyzer Based on Membrane Diffusion for Ammonia Control in Wastewater Treatment Process
Ammonia is a necessary monitoring parameter should be controlled within an optimum range in the whole process of wastewater treatment and recycle, but few reliable real-time monitoring technologies are available currently under such harsh water condition. This study proposed a continuous conductimetric flow-through analyser for ammonia monitoring (CFAA) in the wastewater treatment process. It is developed based on the gas diffusion mechanisms, and the proposed analytical principle has been validated that the real-time conductivity increment rate is linearly proportional to the real-time ammonia concentration in the sample. This method could be generally applicable in monitoring a wide ammonia concertation range (10.2 µg L-1 to 500 mg L-1), and it is capable of achieving long-term ammonia monitoring by periodical renewal of the receiving solution. The potential impact factors and corresponding calibration principles are also developed to avoid tedious ongoing calibration. The field application results demonstrate that CFAA can effectively and directly achieve real-time and average ammoniacal nitrogen monitoring at different treatment stages regardless of the complexity of wastewater, not requiring any sample pre-treatment. Compared with other ammonia on-line monitoring technologies, the proposed CFAA shows remarkable advantages in high reliability, durability and accuracy, especially under severe monitoring condition. It can be a useful monitoring tool for continuous ammonia control in the wastewater treatment process.
- 7 June 2019
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 4 (7) , 1881-1888
Online Conductimetric Flow-Through Analyzer Based on Membrane Diffusion for Ammonia Control in Wastewater Treatment Process
Ammonia is a necessary monitoring parameter should be controlled within an optimum range in the whole process of wastewater treatment and recycle, but few reliable real-time monitoring technologies are available currently under such harsh water condition. This study proposed a continuous conductimetric flow-through analyser for ammonia monitoring (CFAA) in the wastewater treatment process. It is developed based on the gas diffusion mechanisms, and the proposed analytical principle has been validated that the real-time conductivity increment rate is linearly proportional to the real-time ammonia concentration in the sample. This method could be generally applicable in monitoring a wide ammonia concertation range (10.2 µg L-1 to 500 mg L-1), and it is capable of achieving long-term ammonia monitoring by periodical renewal of the receiving solution. The potential impact factors and corresponding calibration principles are also developed to avoid tedious ongoing calibration. The field application results demonstrate that CFAA can effectively and directly achieve real-time and average ammoniacal nitrogen monitoring at different treatment stages regardless of the complexity of wastewater, not requiring any sample pre-treatment. Compared with other ammonia on-line monitoring technologies, the proposed CFAA shows remarkable advantages in high reliability, durability and accuracy, especially under severe monitoring condition. It can be a useful monitoring tool for continuous ammonia control in the wastewater treatment process.
- 8 November 2017
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 51 (22) , 13265-13273
Gas-Permeable Membrane-Based Conductivity Probe Capable of In Situ Real-Time Monitoring of Ammonia in Aquatic Environments
Aquatic ammonia has toxic effects on aquatic life. This work reports a gas-permeable membrane-based conductivity probe (GPMCP) developed for real-time monitoring of ammonia in aquatic environments. The GPMCP innovatively combines a gas-permeable membrane with a boric acid receiving phase to selectively extract ammonia from samples and form ammonium at the inner membrane interface. The rate of the receiving phase conductivity increase is directly proportional to the instantaneous ammonia concentration in the sample, which can be rapidly and sensitively determined by the embedded conductivity detector. A precalibration strategy was developed to eliminate the need for an ongoing calibration. The analytical principle and GPMCP performance were systematically validated. The laboratory results showed that ammonia concentrations ranging from 2 to 50 000 μg L–1 can be detected. The field deployment results demonstrated the GPMCP’s ability to obtain high-resolution continuous ammonia concentration profiles and the absolute average ammonia concentration over a prolonged deployment period. By inputting the temperature and pH data, the ammonium concentration can be simultaneously derived from the corresponding ammonia concentration. The GPMCP embeds a sophisticated analytical principle with the inherent advantages of high selectivity, sensitivity, and accuracy, and it can be used as an effective tool for long-term, large-scale, aquatic-environment assessments.
- 8 November 2017
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 51 (22) , 13265-13273
Gas-Permeable Membrane-Based Conductivity Probe Capable of In Situ Real-Time Monitoring of Ammonia in Aquatic Environments
Aquatic ammonia has toxic effects on aquatic life. This work reports a gas-permeable membrane-based conductivity probe (GPMCP) developed for real-time monitoring of ammonia in aquatic environments. The GPMCP innovatively combines a gas-permeable membrane with a boric acid receiving phase to selectively extract ammonia from samples and form ammonium at the inner membrane interface. The rate of the receiving phase conductivity increase is directly proportional to the instantaneous ammonia concentration in the sample, which can be rapidly and sensitively determined by the embedded conductivity detector. A precalibration strategy was developed to eliminate the need for an ongoing calibration. The analytical principle and GPMCP performance were systematically validated. The laboratory results showed that ammonia concentrations ranging from 2 to 50 000 μg L–1 can be detected. The field deployment results demonstrated the GPMCP’s ability to obtain high-resolution continuous ammonia concentration profiles and the absolute average ammonia concentration over a prolonged deployment period. By inputting the temperature and pH data, the ammonium concentration can be simultaneously derived from the corresponding ammonia concentration. The GPMCP embeds a sophisticated analytical principle with the inherent advantages of high selectivity, sensitivity, and accuracy, and it can be used as an effective tool for long-term, large-scale, aquatic-environment assessments.