Survey of posteroanterior chest radiography in The Netherlands: patient dose and image quality
Authors:
- D ZweersDZD Zweers
- L van Den BergLBL van Den Berg
- J GeleijnsJGJ Geleijns
- J Th M JansenJJJ Th M Jansen
- J ZoeteliefJZJ Zoetelief
- 1 June 2003
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 76 (906) , 398-405
Abstract
Council Directive 97/43/Euratom (Medical Exposure Directive) states that member States of the European Union shall promote the establishment and use of diagnostic reference levels for radio-diagnostic examinations. Dose surveys can form the basis for the establishment of diagnostic reference levels. In view of the implementation of the Medical Exposure Directive in the Netherlands, a survey of dose and image quality has been performed for posteroanterior (PA) chest radiography in 2001. In this survey, 25 participants were selected from a list of 175 Dutch hospitals, whereas in a previous PA chest survey (about 10 years ago) participation was voluntary and participants came predominantly from the south-western part of the Netherlands. For conventional screen-film PA chest radiography, the present results for patient dose and image quality are quite similar to those results from the previous survey. The fraction of conventional X-ray systems utilizing lung compensation filters has remained approximately the same. For dedicated digital chest radiography systems, image quality is better than for conventional systems, but doses vary and can assume relatively high values. The results indicate that there are still possibilities for dose reduction, without loss of image quality. The 75 percentile value of the entrance surface dose distribution is approximately 0.13 mGy.Keywords
This publication has 19 references indexed in Scilit:
- The Relevance of Different Quantities for Risk Estimation in Diagnostic RadiologyRadiation Protection Dosimetry, 1998
- A comparison of patient dose for examinations of the upper gastrointestinal tract at 11 conventional and digital X-ray units in The Netherlands.British Journal of Radiology, 1998
- Patient dose due to colon examination: dose assessment and results from a survey in The Netherlands.Radiology, 1997
- Survey of CT techniques and absorbed dose in various Dutch hospitals.British Journal of Radiology, 1997
- Calculation of dose conversion factors for posterior–anterior chest radiography of adults with a relatively high-energy X-ray spectrumBritish Journal of Radiology, 1994
- Image Quality and Dosimetric Aspects of Chest X Ray Examinations: Measurements with Various Types of PhantomsRadiation Protection Dosimetry, 1993
- Determination of Image Quality in Relation to Absorbed Dose in MammographyRadiation Protection Dosimetry, 1993
- AMBER and conventional chest radiography: comparison of radiation dose and image quality.Radiology, 1992
- European Intercomparison of Diagnostic Dosemeters: ResultsRadiation Protection Dosimetry, 1992
- Beam quality independent attenuation phantom for estimating patient exposure from x-ray automatic exposure controlled chest examinationsMedical Physics, 1984