Mid-term results of the modular ANCA-Fit femoral component in total hip replacement
- 1 December 2009
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 91-B (12) , 1561-1565
Abstract
We report the minimum five-year follow-up of 352 primary total hip replacements using the uncemented hydroxyapatite-coated ANCA-Fit femoral component with a modular neck and head. The series comprised 319 patients (212 men, 107 women) with a mean age at operation of 64.4 years (28 to 97). The principal diagnosis was osteoarthritis. A total of 18 patients (21 hips) died before their follow-up at five years, nine patients (11 hips) were lost to follow-up, and four (four hips) declined further follow-up. Patient-reported outcomes have been recorded for 288 patients (316 hips). Their mean Oxford Hip Score improved significantly from 41 points (16 to 57) pre-operatively to 20 points (12 to 44) at five-year follow-up. Radiological assessment showed good bony stability in 98% of implants. There were two cases of aseptic loosening of the femoral component. There were no clinical or radiological complications related to modularity. In our series we did not see the high rate of intra-operative fracture previously reported for this implant. This medium-term follow-up study demonstrates that the clinical outcome of the ANCA-Fit femoral component is, to date, comparable with that of other metaphyseal loading femoral components.Keywords
This publication has 17 references indexed in Scilit:
- Effect of Femoral Component Offset on Polyethylene Wear in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2001
- Anatomic Cementless Total Hip Arthroplasty with Ceramic Bearings and Modular Necks: 3 to 5 Years Follow-UpHIP International, 2001
- Custom and Modular Components in Primary Total Hip ReplacementClinical Orthopaedics and Related Research, 1997
- QUESTIONNAIRE ON THE PERCEPTIONS OF PATIENTS ABOUT TOTAL HIP REPLACEMENTThe Journal of Bone and Joint Surgery. British volume, 1996
- Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 1995
- Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings.Journal of Bone and Joint Surgery, 1994
- Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants.Journal of Bone and Joint Surgery, 1994
- The significance of the Trendelenburg testThe Journal of Bone and Joint Surgery. British volume, 1985
- "Modes of Failure" of Cemented Stem-type Femoral ComponentsClinical Orthopaedics and Related Research, 1979
- Ectopic Ossification Following Total Hip ReplacementJournal of Bone and Joint Surgery, 1973