Investigating workload and usability of remote magnetic navigation for catheter ablation
Open Access
- 15 December 2025
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (3) , 651-660
Abstract
Purpose: Robotic systems for catheter ablation have been in clinical use for many years. While their impact on the clinical outcome and procedure times is well studied, aspects like usability and operator workload have received limited attention in the literature. Reduced workload and stress levels benefit the operator’s mental and physical health, and can also lower the risk of errors and ultimately improve patient safety. The aim of this study is to investigate the workload and usability of remote magnetic navigation compared to conventional manual navigation. Methods: We performed a user study with eight electrophysiologists. Each participant performed identical in-vitro navigation tasks replicating those found in pulmonary vein isolation using both manual and magnetic navigation. Magnetic navigation experiments were performed using the Navion, a mobile electromagnetic navigation system. Results: Magnetic navigation significantly improved usability ( p < 0.02) and workload ( p < 0.01) compared to manual navigation, measured using the System Usability Scale (magnetic: 85.6 ± 9.3 vs. manual: 75.0 ± 17.8) and NASA Task Load Index (magnetic: 72.4 ± 13.5 vs. manual: 45.8 ± 16.7). Additionally, task completion times were shorter ( p < 0.01) with magnetic navigation (284.6 ± 80.7 s) compared to manual navigation (411.0 ± 123.7 s). Conclusion: The findings of this study suggest that remote magnetic navigation using the Navion significantly improves operator experiences in terms of workload and usability, reinforcing the case for wider adoption of well-designed robotic systems in cardiac electrophysiology labs.Keywords
Funding Information
- Horizon 2020 (101016834)
- Swiss Federal Institute of Technology Zurich
This publication has 28 references indexed in Scilit:
- Parametric Design of Continuum Robots Using Interlocking Ball JointsAdvanced Intelligent Systems, 2025
- Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K studyNature Medicine, 2024
- A Human‐Scale Clinically Ready Electromagnetic Navigation System for Magnetically Responsive Biomaterials and Medical DevicesAdvanced Materials, 2024
- Contact force sensing manual catheter versus remote magnetic navigation ablation of atrial fibrillation: a single-center comparisonHeart and Vessels, 2024
- Addressing Surgeon Burnout Through a Multi-level Approach: A National Call to ActionCurrent Trauma Reports, 2023
- Patient selection, peri-procedural management, and ablation techniques for catheter ablation of atrial fibrillation: an EHRA surveyEP Europace, 2022
- Burnout among surgeons and surgical trainees: A systematic review and meta-analysis of the prevalence and associated factorsSurgery in Practice and Science, 2022
- Utilization of steerable sheath improves the efficiency of atrial fibrillation ablation guided by robotic magnetic navigation compared with fixed‐curve sheathClinical Cardiology, 2022
- 2019 ESC Guidelines for the management of patients with supraventricular tachycardiaThe Task Force for the management of patients with supraventricular tachycardia of the European Society of Cardiology (ESC)European Heart Journal, 2019
- Robotic Magnetic Navigation for Atrial Fibrillation AblationJACC, 2006