FHFlorian Heemeyer

Florian Heemeyer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Florian Heemeyer has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Multidimensional Perspective on Network Conditions in Telesurgery

    by Florian Heemeyer, Marco Cina, Ege Cem Kirci, Laurent Vanbever, Quentin Boehler

    Telesurgery enables remote access to surgical care using robotic systems, with performance influenced by the conditions of the network over which the procedure is performed. Existing studies primarily evaluate individual parameters in isolation, such as latency or bandwidth, neglecting that real‐world networks can exhibit multiple impairments simultaneously. In this work, we understand network conditions as a multidimensional space and analyze their combined effects on telesurgical performance. We conducted a pilot user study using in vitro neurovascular navigation tasks performed remotely with an electromagnetic navigation system across varying levels of latency, bandwidth, jitter, and packet loss. We investigated how performance degrades under worsening network conditions and employed response surface methodology to identify significant parameters and interactions. Results show that degraded network conditions lead to reduced perceived feasibility, longer completion times, and higher overshoot. Performance depends on multiple parameters and their interactions, with latency and packet loss as dominant factors. These findings highlight the importance of multidimensional network characterization for understanding telesurgery performance and its practical deployment. This work provides the foundation for deriving system‐specific network requirements and identifying reliable and safe operating regions for telesurgical robotic systems.

  • Expanding the Workspace of Electromagnetic Navigation Systems Using Dynamic Feedback for Single- and Multi-Agent Control

    by Jasan Zughaibi, Denis von Arx, Maurus Derungs, Florian Heemeyer, Luca A. Antonelli, Quentin Boehler, Michael Muehlebach, Bradley J. Nelson


  • Open Access

    Investigating workload and usability of remote magnetic navigation for catheter ablation

    by Florian Heemeyer, Leonardo E. Guido Lopez, Miguel E. Jáuregui Abularach, Beatriz Sanz Verdejo, Quentin Boehler, Oliver Brinkmann, José L. Merino, Bradley J. Nelson

    Purpose: Robotic systems for catheter ablation have been in clinical use for many years. While their impact on the clinical outcome and procedure times is well studied, aspects like usability and operator workload have received limited attention in the literature. Reduced workload and stress levels benefit the operator’s mental and physical health, and can also lower the risk of errors and ultimately improve patient safety. The aim of this study is to investigate the workload and usability of remote magnetic navigation compared to conventional manual navigation. Methods: We performed a user study with eight electrophysiologists. Each participant performed identical in-vitro navigation tasks replicating those found in pulmonary vein isolation using both manual and magnetic navigation. Magnetic navigation experiments were performed using the Navion, a mobile electromagnetic navigation system. Results: Magnetic navigation significantly improved usability ( p < 0.02) and workload ( p < 0.01) compared to manual navigation, measured using the System Usability Scale (magnetic: 85.6 ± 9.3 vs. manual: 75.0 ± 17.8) and NASA Task Load Index (magnetic: 72.4 ± 13.5 vs. manual: 45.8 ± 16.7). Additionally, task completion times were shorter ( p < 0.01) with magnetic navigation (284.6 ± 80.7 s) compared to manual navigation (411.0 ± 123.7 s). Conclusion: The findings of this study suggest that remote magnetic navigation using the Navion significantly improves operator experiences in terms of workload and usability, reinforcing the case for wider adoption of well-designed robotic systems in cardiac electrophysiology labs.


  • Open Access

    Parametric Design of Continuum Robots Using Interlocking Ball Joints

    by Alexandre Mesot, Quentin Boehler, Florian Heemeyer, Sean Lyttle, Buse Aktaş, Bradley J. Nelson

    Continuum robots are promising systems for minimally invasive surgical procedures, enabling safe and dexterous access to deep regions in the human body. Their design and fabrication can be adapted to a wide range of application‐specific requirements. Unfortunately, the current lack of standardized methods for producing these designs impedes the development and adoption of new continuum robots (CRs). Herein, a parametric design methodology is introduced for producing a wide variety of CRsbased on application‐specific requirements. This approach is based on interlocking ball joint subunits that enable the generation of modular systems. The methodology is demonstrated by designing a magnetically actuated continuum robot for cardiac ablations. The design is generated using an open‐source parametric computer‐aided design toolbox, and prototypes are experimentally validated in vitro and ex vivo, demonstrating the ability of the toolbox to produce functional systems with minimal effort and input from the user.


  • Top Cited Papers

    Telesurgery and the importance of context

    by Florian Heemeyer, Quentin Boehler, Minsoo Kim, Bernard R. Bendok, Evelyn L. Turcotte, H. Hunt Batjer, Ryan D. Madder, Vitor M. Pereira, Bradley J. Nelson

    Telesurgery has the potential to overcome geographical barriers in surgical care, encouraging its deployment in areas with sparse surgical expertise. Despite successful in-human experiments and substantial technological progress, the adoption of telesurgery remains slow. In this Review, we analyze the reasons for this slow adoption. First, we identify various contexts for telesurgery and highlight the vastly different requirements for their realization. We then discuss why procedures with high urgency and skill sparsity are particularly suitable for telesurgery. Last, we summarize key research areas essential for further progress. The goal of this Review is to provide the reader with a comprehensive analysis of the current state of telesurgery research and to provide guidance for faster adoption of this exciting technology.


  • Open Access

    Teleoperated Magnetic Endoscopy: A Case Study and Perspective

    by Alexandre Mesot, Michelle Mattille, Quentin Boehler, Nina Schmid, Sean Lyttle, Florian Heemeyer, Shannon Melissa Chan, Philip Wai Yan Chiu, Bradley James Nelson

    Teleoperated robotic surgery is a rapidly growing field that promises to overcome geographical barriers and share expertise over long distances for a variety of minimally invasive procedures. A particularly promising technology for teleoperation is robotic magnetic navigation. In contrast to conventional surgical robots, a robotic magnetic navigation system generates external magnetic fields to safely and dexterously steer soft magnetic devices within the human body, enabling a versatile, economical, and accessible telesurgery platform for a variety of procedures. This perspective highlights the recent research efforts in robotic magnetic platforms for telesurgery and their translation to clinical settings in the context of endoscopic procedures. This discussion is supported by a case study performed at the Multi‐Scale Medical Robotics Center in Hong Kong, where an in vivo gastroscopy in a porcine model is performed in tandem with two operators, alternating between a clinician controlling the procedure from the operating room in Hong Kong and a remote expert controlling the procedure from an operator console in Zurich. The achievements and challenges of this study highlight the capabilities and future potential of robotic magnetic navigation for telesurgery.


  • Robotic Catheter Ablation: An Evaluation and Prototyping Platform

    by Florian Heemeyer, Quentin Boehler, Christophe Chautems, Leonardo E. Guido López, Miguel Jáuregui-Abularach, José L. Merino, Bradley J. Nelson

    Cardiac arrhythmia affects a large portion of the population, particularly the elderly. As the population ages, the number of patients suffering from this condition is expected to rise, underlining the importance of more efficient treatment methods. Radio-frequency (RF) catheter ablation is the treatment of choice for many cardiac arrhythmias. To recover a normal heartbeat, the abnormal pacemakers inside the heart are first identified and then isolated or destroyed by applying RF energy through the use of an ablation catheter. While the catheter’s design and precise navigation are topics of significant interest, there is currently no standardized evaluation setup to compare different catheter ablation systems. This paper addresses this problem by introducing an evaluation platform including an in vitro anatomical model, a catheter tracking system, and a dedicated graphical user interface. This platform enables performance assessment of catheter ablation systems using various metrics, such as procedure duration, contact stability, ablation angle and user satisfaction. A simulation environment is also presented, allowing for rapid assessment of usability-related parameters. We demonstrate the efficacy of the evaluation platform through a proof-of-concept study, and the efficacy of the simulation environment through evaluating different control gains.