3D cosmic-ray muon tomography using portable muography detector
Open Access
- 1 January 2022
- journal article
- research article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (01) , P01009
Abstract
A feasibility demonstration of three-dimensional (3D) muon tomography was performed for infrastructure equivalent targets using the proposed portable muography detector. For the target, we used two sets of lead blocks placed at different heights. The detector consists of two muon position-sensitive detectors, made of plastic scintillating fibers (PSFs) and multi-pixel photon counters (MPPCs) with an angular resolution of 8 msr. In this work, the maximum likelihood-expectation maximization (ML-EM) method was used for the 3D imaging reconstruction of the muography. For both simulation and experiment, the reconstructed positions of the blocks produce consistent results with prior knowledge of the blocks' arrangement. This result demonstrates the potential of the 3D tomographic imaging of infrastructure by using seven detection positions for portable muography detectors to image infrastructure scale targets.Keywords
This publication has 14 references indexed in Scilit:
- Discovery of a big void in Khufu’s Pyramid by observation of cosmic-ray muonsNature, 2017
- Application of Emulsion Cloud Chamber to cosmic-ray muon radiographyRadiation Measurements, 2015
- Muographic mapping of the subsurface density structures in Miura, Boso and Izu peninsulas, JapanScientific Reports, 2015
- Radiographic visualization of magma dynamics in an erupting volcanoNature Communications, 2014
- Subsurface density mapping of the earth with cosmic ray muonsNuclear Physics B - Proceedings Supplements, 2013
- Imaging Fukushima Daiichi reactors with muonsAIP Advances, 2013
- Detecting a mass change inside a volcano by cosmic‐ray muon radiography (muography): First results from measurements at Asama volcano, JapanGeophysical Research Letters, 2009
- High resolution imaging in the inhomogeneous crust with cosmic-ray muon radiography: The density structure below the volcanic crater floor of Mt. Asama, JapanEarth and Planetary Science Letters, 2007
- Distance-driven projection and backprojection in three dimensionsPhysics in Medicine & Biology, 2004
- Maximum Likelihood Reconstruction for Emission TomographyIEEE Transactions on Medical Imaging, 1982