KCKullapha Chaiwongkhot

Kullapha Chaiwongkhot

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kullapha Chaiwongkhot has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Signal Calibration and Energy Resolution Optimization of a Double-Sided Silicon Strip Detector for Lunar-Based Particle Detection

    by Thanayuth Panyalert, Shariff Manuthasna, Peerapong Torteeka, Xu He, Ning Zhang, Jianing Zheng, Bin Zhang, Dong Yang, Haibo Yang, Jingtian Xian, et al.

    This paper presents a signal calibration and energy resolution analysis of a Double-Sided Silicon Strip Detector (DSSD) developed for charged particle detection in a lunar-based space environment. The detector is part of the Moon-Aiming Thai-Chinese Hodoscope (MATCH), a proposed scientific payload for the Chang'E-7 lunar orbiter, aimed at monitoring space weather and lunar-surface particle interactions. To evaluate the DSSD's performance under vacuum conditions, alpha sources (Am-241 and Pu-239) were used to generate energy spectra, which were processed through baseline correction and histogram generation. Four peak models Gaussian, Gaussian + Exponential Tail, Exponentially Modified Gaussian (EMG), and Hyper-EMG were compared using nonlinear least squares. Results show that the Hyper-EMG model yields superior fits, especially for Am-241, achieving an average reduced chi-squared of 1.64 $\pm$ 4.44 and energy resolution of 3.09% $\pm$ 0.45%, with 22 out of 32 AIC wins. In contrast, Gaussian fits showed higher fitting errors (e.g., $\chi ^{2}$/DoF up to 10.5) and the poorest resolution. Akaike Information Criterion (AIC) selection further confirms Hyper-EMG's robustness, while Gaussian fits were consistently inadequate. These findings support the use of tail-aware models like Hyper-EMG for accurate energy reconstruction in spaceborne silicon detectors.


  • Open Access

    Coincident signals on multiple counters in a neutron monitor: Sparse vs. dense atmospheric secondary particles from cosmic ray showers 

    by Kullapha Chaiwongkhot, David Ruffolo, Poompong Chaiwongkhot, Alejandro Sáiz, Chanoknan Banglieng

    Neutron monitors were designed to measure atmospheric secondary neutrons from cosmic ray showers in order to track the cosmic ray flux vs. time.  Furthermore, at the Princess Sirindhorn Neutron Monitor (PSNM), an 18-counter NM64 detector at 2560-m altitude at Doi Inthanon, Thailand, the leader fraction (inverse multiplicity) inferred from time delay distribution between successive neutron events in the same counter has been used to track spectral variations.  More recent measurements of time delays between neutron events in different counters, as a function of counter separation, have confirmed that 1) the product neutrons from the interaction of a single atmospheric secondary neutron can spread among neighboring counters, with a cross-counter leader fraction that depends on whether the first counter is an end or middle counter, and 2) coincident counts between distant counters can be produced by multiple atmospheric secondary neutrons from the same primary cosmic ray, with a leader fraction that depends on whether the second counter is an end or middle counter.  Here we report on measurements of neutron signals in amplifier outputs at PSNM using a 4-channel oscilloscope, in order to further investigate these phenomena.  For a pair of neighboring counters located at the edge of the counter array, we find roughly equal event rates in either neighbor following a neutron trigger in one of them, implying that the difference in leader fraction relates to the base count rate of the first counter and is therefore lower if that is an end counter. In addition, an FPGA-based readout system was developed for more efficient collection of neutron events on two distant counters (Tubes 2 and 18) that were coincident within a 250-microsecond time window, while also monitoring Tube 10 in between.  The time distributions and neutron multiplicities indicate that a small fraction of the cosmic ray events that triggered both Tubes 2 and 18 also led to neutron events on Tube 10 with an enhanced rate of high multiplicity, indicating a few air shower events that densely “carpeted” the neutron monitor, while the majority of such coincidences apparently involved a sparse distribution of isolated secondary particles near Tube 2 and near Tube 18 and not near the intermediate Tube 10, which is consistent with a cross-counter leader fraction dependence on the count rate of the second counter.  This research was supported by the postdoctoral research sponsorship of Mahidol University, Thailand, by grant RTA6280002 from Thailand Science Research and Innovation, and by grant NSRF from the Program Management Unit for Human Resources & Institutional Development, Research and Innovation, NXPO, Thailand [grant number B05F640051]. 

  • Open Access

    3D cosmic-ray muon tomography using portable muography detector

    by K. Chaiwongkhot, T. Kin, Y. Nagata, T. Komori, N. Okamoto, H. Basiri

    A feasibility demonstration of three-dimensional (3D) muon tomography was performed for infrastructure equivalent targets using the proposed portable muography detector. For the target, we used two sets of lead blocks placed at different heights. The detector consists of two muon position-sensitive detectors, made of plastic scintillating fibers (PSFs) and multi-pixel photon counters (MPPCs) with an angular resolution of 8 msr. In this work, the maximum likelihood-expectation maximization (ML-EM) method was used for the 3D imaging reconstruction of the muography. For both simulation and experiment, the reconstructed positions of the blocks produce consistent results with prior knowledge of the blocks' arrangement. This result demonstrates the potential of the 3D tomographic imaging of infrastructure by using seven detection positions for portable muography detectors to image infrastructure scale targets.


  • Measurement and simulation of the neutron propagation time distribution inside a neutron monitor

    by K. Chaiwongkhot, D. Ruffolo, W. Yamwong, J. Prabket, P.-S. Mangeard, A. Sáiz, W. Mitthumsiri, C. Banglieng, E. Kittiya, W. Nuntiyakul, et al.


  • A Feaibility Study of 3D Cosmic-Ray Muon Tomography with a Portable Muography Detector

    by Kullapha Chaiwongkhot, Tadahiro Kin, Ryo Sasaki, Hikaru Sato, Yuta Nagata, Tomohiro Komori, Yukinobu Watanabe


  • Development of a Portable Muography Detector for Infrastructure Degradation Investigation

    by Kullapha Chaiwongkhot, Tadahiro Kin, Hiroaki Ohno, Ryo Sasaki, Yuta Nagata, Kazuhiro Kondo, Yukinobu Watanabe

    A portable muography detector was developed for measuring infrastructure degradation and its performance was tested. The detector consists of two muon position sensitive detectors (mu-PSDs) of the area of 140 mm $\times \,\, 140$ mm, placed in a compact light-shielding box. Each mu-PSD consists of plastic scintillating fibers connected to multipixel photon counters (MPPCs). To suppress the gain deviation of the MPPCs, the box was heat insulated and its inner air temperature was maintained by Peltier cooling–heating modules. The mu-PSD pixel size was 8.75 mm $\times \,\, 8.75$ mm and the distance between the two mu-PSDs was set to 100 mm in order to achieve a solid angle resolution of 8 msr when measuring typical pieces of infrastructure at thicknesses of several tens of centimeters. The intensity of cosmic-ray muons was measured as a function of zenith angle on the ground and was found to be in good agreement with the well-known empirical formula for muon intensity at Earth’s surface. The structural interior of a seven-story concrete building was then successfully imaged with the muography detector placed in the building’s basement.


  • Development of a prototype portable muography detector for exploration of underground cavities

    by Kullapha Chaiwongkhot, Tadahiro Kin, Hiroaki Ohno, Kazuhiro Kondo, Hikaru Sato, Yukinobu Watanabe

    A prototype portable muography detector was developed for exploration of underground cavities and some performance tests were conducted. The detector consists of two muon position sensitive detectors (mu-PSDs) having an area size of 140 mm × 140 mm which were placed in a compact light shielding box. Each mu-PSD was fabricated using plastic scintillating fibers (PSFs) connected to multi-pixel photon counters (MPPCs). The pixel size of 8.75 mm × 8.75 mm and the distance of 100 mm between the two mu-PSDs were determined so as to satisfy the solid angle resolution of 30 msr required from subsidence risk cavity exploration. The detector system worked stably by using a Peltier cooling and heating module for temperature control function. An imaging test of interior structure of a seven-story concrete building was successfully performed using the muography detector placed on the basement.