Changing Patterns in Anesthetic Fresh Gas Flow Rates Over 5 Years in a Teaching Hospital
Authors:
- R Ross KennedyRKR Ross Kennedy
- Richard A. FrenchRFRichard A. French
- 1 May 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 106 (5) , 1487-1490
Abstract
Reducing anesthetic fresh gas flows can reduce volatile anesthetic consumption without affecting drug delivery to the patient. Delivery systems with electronic flow transducers permit the simple and accurate collection of fresh gas flow information. In a 2001 audit of fresh gas flow, we found little response to interventions designed to foster more efficient use of fresh gas. We compared current practice with our earlier results. Flow data were collected in areas with a mix of general and acute surgery in March and November 2001, and again during 2006, by recording directly from the Datex ADU to a computer every 10 s. We extracted the distribution of flow rates when a volatile anesthetic was being administered. Data collection in March 2001 and 2006 was not advertised. In 2001, the mean flow rates were 1.95 and 2.1 L/min with a median flow of 1.5 L/min. In 2006, the mean was 1.27 and the median in the range 0.5-1.0 L/min. Isoflurane use decreased from 47% in 2001 to 4% in 2006. Fresh gas flows used in our department have decreased by 35% over 4 years. Although the absolute change in flow rate is not large, this represents potential annual savings of more than $US130,000. This occurred without specific initiatives, suggesting an evolution in practice towards lower fresh gas flow. Improvements in equipment and monitoring, including a locally developed system, which displays forward predictions of end-tidal and effect-site vapor concentrations, may be factors in this change.Keywords
This publication has 8 references indexed in Scilit:
- The Effect of Using Different Values for the Effect-Site Equilibrium Half-Time on the Prediction of Effect-Site Sevoflurane Concentration: A Simulation StudyAnesthesia & Analgesia, 2005
- Increase in the use of rebreathing gas flow systems and in the utilization of low fresh gas flows in Finnish anaesthetic practice from 1995 to 2002Acta Anaesthesiologica Scandinavica, 2005
- Time course of inhaled anaesthetic drug delivery using a new multifunctional closed-circuit anaesthesia ventilator. In vitro comparison with a classical anaesthesia machine †British Journal of Anaesthesia, 2004
- The Effect of a Model-Based Predictive Display on the Control of End-Tidal Sevoflurane Concentrations During Low-Flow AnesthesiaAnesthesia & Analgesia, 2004
- Fresh gas flow is not the only determinant of volatile agent consumption: a multi-centre study of low-flow anaesthesia † †Conflict of interest: This study was funded by a grant from Daäger South Africa (Pty) Ltd. and coordinated by the Technology and Business Development Group of Medical Research Council of South Africa (MRC).British Journal of Anaesthesia, 2002
- A new device to reduce the consumption of a halogenated anaesthetic agent*Anaesthesia, 2001
- Individualized Feedback of Volatile Agent Use Reduces Fresh Gas Flow Rate, but Fails to Favorably Affect Agent ChoiceAnesthesiology, 1999
- Reinforcing a “Low Flow” Anaesthesia Policy with Feedback Can Produce a Sustained Reduction in Isoflurane ConsumptionAnaesthesia and Intensive Care, 1998