RKR. Ross Kennedy

R. Ross Kennedy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


R. Ross Kennedy has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 September 2011
      • Vol. 39  (5) , 946-50

    A New Zealand based cohort study of anaesthetic trainees' career outcomes compared with previously expressed intentions.

    by E M L Moran, R A French, R R Kennedy

    Predicting workforce requirements is a difficult but necessary part of health resource planning. A 'snapshot' workforce survey undertaken in 2002 examined issues that New Zealand anaesthesia trainees expected would influence their choice of future workplace. We have restudied the same cohort to see if that workforce survey was a good predictor of outcome. Seventy (51%) of 138 surveys were completed in 2009 compared with 100 (80%) of 138 in the 2002 survey. Eighty percent of the 2002 respondents planned consultant positions in New Zealand. We found 64% of respondents were working in New Zealand (P < 0.01). We found that family ties were an important influence on the choice of country of residence for 80% of New Zealand based respondents but only 40% of those living outside New Zealand agreed or strongly agreed with this statement (P < 0.01). Remuneration influenced country of residence for 76% of those living outside New Zealand but was important for only 2% of those resident in New Zealand (P < 0.01). Salaries in New Zealand were predominantly between NZ$150,000 and $200,000 while those overseas received between NZ$300,000 and $400,000. Of those that are resident in New Zealand, 84% had studied in a New Zealand medical school compared with 52% of those currently working overseas (P < 0.01). Our study shows that stated career intentions in a group do not predict the actual group outcomes. We suggest that 'snapshot' studies examining workforce intentions are of little value for workforce planning. However we believe an ongoing program matching career aspirations against career outcomes would be a useful tool in workforce planning.

  • Changing Patterns in Anesthetic Fresh Gas Flow Rates Over 5 Years in a Teaching Hospital

    by R Ross Kennedy, Richard A. French

    Reducing anesthetic fresh gas flows can reduce volatile anesthetic consumption without affecting drug delivery to the patient. Delivery systems with electronic flow transducers permit the simple and accurate collection of fresh gas flow information. In a 2001 audit of fresh gas flow, we found little response to interventions designed to foster more efficient use of fresh gas. We compared current practice with our earlier results. Flow data were collected in areas with a mix of general and acute surgery in March and November 2001, and again during 2006, by recording directly from the Datex ADU to a computer every 10 s. We extracted the distribution of flow rates when a volatile anesthetic was being administered. Data collection in March 2001 and 2006 was not advertised. In 2001, the mean flow rates were 1.95 and 2.1 L/min with a median flow of 1.5 L/min. In 2006, the mean was 1.27 and the median in the range 0.5-1.0 L/min. Isoflurane use decreased from 47% in 2001 to 4% in 2006. Fresh gas flows used in our department have decreased by 35% over 4 years. Although the absolute change in flow rate is not large, this represents potential annual savings of more than $US130,000. This occurred without specific initiatives, suggesting an evolution in practice towards lower fresh gas flow. Improvements in equipment and monitoring, including a locally developed system, which displays forward predictions of end-tidal and effect-site vapor concentrations, may be factors in this change.


  • Open Access

    Effect-site half-time for burst suppression is longer than for hypnosis during anaesthesia with sevoflurane

    by R. R. Kennedy, C. Minto, A. Seethepalli

    The relationship between measures of drug effect such as bispectral index (BIS) and end-tidal (ET) levels of anaesthetic agents is described by the ‘effect site equilibrium half-time’, t1/2(ke0). There are limited data available on sevoflurane t1/2(ke0) during routine anaesthesia and surgery. Preliminary observations suggested t1/2(ke0) for the degree of hypnosis as estimated by BIS is different from that for burst suppression of the electroencephalograph, occurring at ‘deep’ levels of anaesthesia. This study aimed to determine and compare t1/2(ke0) for these two ‘effects’. Large changes in ET sevoflurane were produced in 13 subjects during surgery. ET sevoflurane, BIS, and burst suppression ratio (BSR) were recorded every 10 s. Data were divided into epochs with BIS>30 (BIS) or with BSR>10% (burst suppression). Using a non-parametric modelling technique, t1/2(ke0) was determined for each epoch. There were 36 ‘BIS’ and 20 burst suppression zones. Mean (sd) t1/2(ke0) for BIS was 3.48 (1.12) min and for BSR 9.9 (6.4) min. In all subjects, t1/2(ke0) BIS<t1/2(ke0) BSR. These differences were statistically significant (Pt1/2(ke0) for these effects suggest different sites or mechanisms of action. These results also establish values of t1/2(ke0) which can be used to provide the real-time estimates of effect-site sevoflurane concentration in clinical practice.


  • The Effect of Using Different Values for the Effect-Site Equilibrium Half-Time on the Prediction of Effect-Site Sevoflurane Concentration: A Simulation Study

    by R Ross Kennedy

    We have developed a predictive display that allows effect-site concentration (Ceff) to be used as a target for administration of inhaled anesthesia. Ceff is dependent on the half-time for plasma effect-site equilibrium [t½½(ke0)]. The t½(ke0) used in the predictive display is fixed and may differ from that in the patient. We wished to explore the effect of this difference on predictions of Ceff. In a computer simulation, fresh gas flow and vaporizer settings required to achieve a predefined time profile for Ceff were determined for t½(ke0) of 2.5, 3.5, and 5 min. The end-tidal values for each simulation were used to recalculate Ceff with each t½(ke0). The maximal deviation at predetermined points, measures of global fit, and the delay in “recovery” were calculated. With a predictive display t½(ke0) of 3.5 min, the maximal error in Ceff was 0.18 vol%, occurring during the wash-in phase and disappearing within 2–3 min. The difference in time for Ceff to decrease from 1.0 to 0.7 vol% was 1.3 min. Results with a display t½(ke0) of 2.5 min or 5 min and simulated patient t½(ke0) of 5 min or 2.5 min were approximately twice as large. These results suggest that Ceff is relatively insensitive to large (50%–100%) variations in t½(ke0).


  • The Effect of a Model-Based Predictive Display on the Control of End-Tidal Sevoflurane Concentrations During Low-Flow Anesthesia

    by R Ross Kennedy, Richard A. French, Sandra Gilles

    We have shown that a multicompartment model accurately predicts end-tidal (ET) sevoflurane (sevo) and isoflurane concentrations. The model has been adapted to use real-time fresh gas flow and vaporizer settings to display a 10-min prediction of ET sevo concentrations. In this study, we evaluated the effect of the predictive display on the speed and accuracy of changes in ET sevo by the anesthesiologist. Fifteen patients were studied in whom sevo-based anesthesia was expected to last more than 2 h. Four step changes of target ET concentration (+0.5, +1.0, -1.0, and -0.5 vol%) were made either unaided or with the prediction display. Fresh gas flow was 1 L/min. Response time, maximum overshoot, and stability in the 5 min after the target was achieved were compared by using two-tailed paired Student's t-tests. Changes were made on average 1.5-2.3 times faster with the predictive display than without it. These differences were statistically significant (P < 0.05) for the +0.5, +1.0, and -0.5 vol% step changes but not for the -1.0 vol% change. There were no differences in the degree of overshoot or stability. These differences are comparable to those seen with an automatic feedback control system. This system may simplify the administration of volatile anesthesia and the use of low-flow anesthesia.


    • 16 May 2003
      • Vol. 116  (1174) , U438

    An audit of anaesthetic fresh-gas flow rates and volatile anaesthetic use in a teaching hospital.

    by Ross Kennedy, Richard French

    The large number of anaesthetics administered means that the total cost to a hospital of inhalational anaesthetic agent such as isoflurane or sevoflurane can be considerable. The total anaesthetic gas flow is a major determinant of the use of these agents. Modern anaesthetic machines and monitoring facilitate reduced gas flows, which can significantly reduce wastage of these anaesthetic agents. The purpose of this study was to audit gas flow rates and volatile anaesthetic use. We audited gas flows and choice of anaesthetic agent over two one-month periods in one theatre at Christchurch Hospital. Data were collected directly from the anaesthetic machine using a computer. The second study period was clearly advised and followed widespread discussion of results from the first study period. Average fresh-gas flow was approximately 2 l/min (Month 1 = 2.0 l/min, Month 2 = 2.1 l/min). Use of the more expensive agent, sevoflurane, increased but gas flows with this agent decreased. Given the low flows used, the small difference between study periods was not surprising. The gas flows recorded represent responsible use of anaesthetic agents and are at least as good as flows achieved in previous studies that employed various methods to encourage their reduction.


  • The Effect of the Interval Between Blood Pressure Determinations on the Delay in the Detection of Changes: A Computer Simulation

    by R. Ross Kennedy, Richard French

    The frequency of automated noninvasive blood pressure (NIBP) measurements during routine anesthesia is a balance between potentially deleterious effects of frequent cycling and a delay in detecting changes caused by a long cycle time. A computer model generated systolic blood pressures that changed to a new, random value after a period of stability. We sampled these data at intervals between 1 and 10 min to simulate NIBP measurements. A separate algorithm, based on Trigg’s Tracking Variable, indicated when a change had been detected. For each set of variables, the simulation was repeated 1000 times, and the average time to detect a change was recorded. The mean time to detect a change was 8.0 min with a 1-min cycle, 8.9 min with a 2-min cycle, 10.8 min with a 5-min cycle, and 13.0 min with a 10-min cycle. As the cycle time increased, the delay in detecting changes increased but only by approximately half the increase in the cycle time. The optimum variables for the trend detection algorithm also changed as the NIBP interval increased. Provided that abrupt changes in blood pressure are not anticipated, a 1- or 2-min cycle time for NIBP offers little advantage over a longer period.


  • Predictive Accuracy of a Model of Volatile Anesthetic Uptake

    by R. Ross Kennedy, Richard A. French, Christopher Spencer

    A computer program that models anesthetic uptake and distribution has been in use in our department for 20 yr as a teaching tool. New anesthesia machines that electronically measure fresh gas flow rates and vaporizer settings allowed us to assess the performance of this model during clinical anesthesia. Gas flow, vaporizer settings, and end-tidal concentrations were collected from the anesthesia machine (Datex S/5 ADU) at 10-s intervals during 30 elective anesthetics. These were entered into the uptake model. Expired anesthetic vapor concentrations were calculated and compared with actual values as measured by the patient monitor (Datex AS/3). Sevoflurane was used in 16 patients and isoflurane in 14 patients. For all patients, the median performance error was −0.24%, the median absolute performance error was 13.7%, divergence was 2.3%/h, and wobble was 3.1%. There was no significant difference between sevoflurane and isoflurane. This model predicted expired concentrations well in these patients. These results are similar to those seen when comparing calculated and actual propofol concentrations in propofol infusion systems and meet published guidelines for the accuracy of models used in target-controlled anesthesia systems. This model may be useful for predicting responses to changes in fresh gas and vapor settings.


  • The effect of cardiac output changes on end-expired volatile anaesthetic concentrations - a theoretical study

    by R. R. Kennedy, A. B. Baker

    Cardiac output is one of the major determinants of the rate of uptake, and therefore the end-expired concentration (F(E')) of volatile anaesthetic agents. The purpose of this theoretical study was to explore the effect of cardiac output changes on F(E') for a range of volatile anaesthetics. A multicompartment model of anaesthetic uptake and distribution which produces constant values of F(E') was used. The minimum detectable change in cardiac output was determined for a variety of anaesthetic agents for four patterns of cardiac output change. The effect of a step change in cardiac output from 5 to 10 l.min(-1) was also recorded. The smallest cardiac output changes (average 33%) were detected with isoflurane. As blood solubility increased or decreased, larger cardiac output changes were needed before they could be detected. With a large step change in cardiac output and with increasing solubility, the final change in F(E') increased but the initial rate of change of F(E') is decreased. A significant cardiac output change will produce a change in volatile anaesthetic uptake. An unexpected change in F(E') should be considered as a possible signal of a sudden cardiac output change. The difference between agents may represent a balance between the amount of agent taken up and the size of the tissue 'sink' for that agent.