Accuracy of LED and Halogen Radiometers Using Different Light Sources
- 1 July 2006
- journal article
- research article
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 18 (4) , 214-222
Abstract
Purpose: To determine the accuracy of commercially available, handheld light‐emitting diode (LED) and halogen‐based radiometers using LED and quartz‐tungsten‐halogen (QTH) curing lights with light guides of various diameters.Methods: The irradiance of an LED curing light (L.E.Demetron 1, SDS/Kerr, Orange, CA, USA) and a QTH curing light (Optilux 501, SDS/Kerr) were measured using multiple units of an LED (Demetron L.E.D. Radiometer, SDS/Kerr) and a halogen radiometer (Demetron 100, SDS/Kerr) and compared with each other and to a laboratory‐grade power meter (control). Measurements were made using five light guides with distal light guide diameters of 4, 7, 8, 10, and 12.5 mm. For each light guide, five readings were made with each of three radiometers of each radiometer type. Data were analyzed with two‐way analysis of variance/Tukey; α=0.05.Results: In general, both handheld radiometer types exhibited significantly different irradiance readings compared with the control meter. Additionally, readings between radiometer types were found to differ slightly, but were correlated. In general, the LED radiometer provided slightly lower irradiance readings than the halogen radiometer, irrespective of light source. With both types of handheld radiometers, the use of the larger‐diameter light guides tended to overestimate the irradiance values as seen in the control, while smaller‐diameter light guides tended to underestimate.CLINICAL SIGNIFICANCE: The evaluated LED or halogen handheld radiometers may be used interchangeably to determine the irradiance of both LED and QTH visible‐light‐curing units. Measured differences between the two radiometer types were small and probably not clinically significant. However, the diameter of light guides may affect the accuracy of the radiometers, with larger‐diameter light guides overestimating and smaller‐diameter guides underestimating the irradiance value measured by the control instrument.Keywords
This publication has 21 references indexed in Scilit:
- Time dependence of composite shrinkage using halogen and LED light curingDental Materials, 2005
- THE EFFECT OF AUTOCLAVING ON ENERGY TRANSMISSION THROUGH LIGHT-CURING TIPSThe Journal of the American Dental Association, 1996
- Light curing unit effectiveness assessed by dental radiometersJournal of Dentistry, 1995
- Evaluating Intensity Output of Curing Lights in Private Dental OfficesThe Journal of the American Dental Association, 1994
- Radiometric and spectroradiometric comparison of power outputs of five visible light-curing unitsJournal of Dentistry, 1993
- Correlation of Parameters used to Estimate Monomer Conversion in a Light-cured CompositeJournal of Dental Research, 1988
- A Comparison of Four Modes of Evaluating Depth of Cure of Light-activated CompositesJournal of Dental Research, 1987
- Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resinsDental Materials, 1985
- Spectral Distributions of Dental Photopolymerization SourcesJournal of Dental Research, 1982
- Factors Affecting the Depth of Cure of UV -polymerized CompositesJournal of Dental Research, 1980