Howard W. Roberts
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Howard W. Roberts has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Amer Tiba
Naval Institute for Dental and Biomedical Research, Great Lakes, IL, USA
1 shared publication Daniel L Leonard
1 shared publicationDavid F. Murchison
1 shared publicationDavid G Charlton
1 shared publicationDavid G. Charlton
Senior research scientist, Naval Institute of Dental and Biomedical Research, Great Lakes, IL, USA
1 shared publication- David G. Charlton
Senior Biomaterials Scientist, Naval Institute for Dental and Biomedical Research, General Dynamics Information Technology, Great Lakes, IL, USA
1 shared publication
Latest Publications
- 1 October 2013
- Published by Maney Publishing in Cranio®
- Vol. 31 (4) , 270-275
Volumetric Wear of Various Orthotic Appliance Materials
The purpose of this study was to compare the resistance to wear of six commonly used orthotic appliance materials. These materials were: SR Ivocap (Ivoclar Vivadent, Inc., Amherst, NY), Eclipse (Dentsply International, York, PA), ProBase (Ivoclar Vivadent), Valplast (Valplast International Corp., Oceanside, NY), Impak (CMP Industries LLC, Albany, NY), and Clearsplint (Astron Dental Corp., Lake Zurich, IL). Twelve cylindrical specimens of each material were fabricated per manufacturer instructions. Occlusal wear was simulated in a custom-made wear simulator with each specimen receiving four wear scars in a two-body wear simulation using a 1.5 mm tungsten-carbide tipped stylus at 40 newtons for 2500 cycles at 1 Hz, while immersed in 37 degrees C distilled water (n = 48). The specimens were evaluated before and after wear testing using a three-dimensional (3D) noncontact profilometer (Proscan 2000, Scantron Corp., Eagan, MN). A mean change in volume was determined for each orthotic material. Results found that Clearsplint material displayed the greatest amount of volume loss/wear, while SR Ivocap, Eclipse, and ProBase materials had the least amount of wear. Valplast and Impak performed more moderately. Based upon this wear knowledge, practitioners are able to more reliably choose the appliance material necessary for their various patients.
- 1 October 2013
- Published by Maney Publishing in Cranio®
- Vol. 31 (4) , 270-275
Volumetric Wear of Various Orthotic Appliance Materials
The purpose of this study was to compare the resistance to wear of six commonly used orthotic appliance materials. These materials were: SR Ivocap (Ivoclar Vivadent, Inc., Amherst, NY), Eclipse (Dentsply International, York, PA), ProBase (Ivoclar Vivadent), Valplast (Valplast International Corp., Oceanside, NY), Impak (CMP Industries LLC, Albany, NY), and Clearsplint (Astron Dental Corp., Lake Zurich, IL). Twelve cylindrical specimens of each material were fabricated per manufacturer instructions. Occlusal wear was simulated in a custom-made wear simulator with each specimen receiving four wear scars in a two-body wear simulation using a 1.5 mm tungsten-carbide tipped stylus at 40 newtons for 2500 cycles at 1 Hz, while immersed in 37 degrees C distilled water (n = 48). The specimens were evaluated before and after wear testing using a three-dimensional (3D) noncontact profilometer (Proscan 2000, Scantron Corp., Eagan, MN). A mean change in volume was determined for each orthotic material. Results found that Clearsplint material displayed the greatest amount of volume loss/wear, while SR Ivocap, Eclipse, and ProBase materials had the least amount of wear. Valplast and Impak performed more moderately. Based upon this wear knowledge, practitioners are able to more reliably choose the appliance material necessary for their various patients.
- 25 December 2008
- Vol. 39 (7) , 573-9
Measurement of select physical and mechanical properties of 3 machinable ceramic materials.
To measure select physical and mechanical properties of 3 machinable ceramic materials (IPS Empress CAD, Ivoclar Vivadent; Vitablocs Mark II, Vident; Paradigm C, 3M ESPE). The physical and mechanical properties tested were hardness (using Vickers hardness), flexural strength and modulus (with 3-point bending), fracture toughness (with Vickers hardness indentation), and coefficient of thermal expansion (using a thermomechanical analyzer). For each of the materials, 25 specimens were fabricated to test each property, except for coefficient of thermal expansion, where n = 5. For each tested property, data were analyzed using 1-way analysis of variance and Tukey Studentized range test (significance level = .05), when required for post hoc testing. Mean Vickers hardness ranged from 511.3 (SD 8.6) for Paradigm C to 569.3 (SD 10.2) for Vitablocs Mark II. Flexural strength was greatest for IPS Empress CAD at 137.51 (SD 23.34) MPa and least for Vitablocs Mark II at 94.08 (SD 14.21) MPa. Flexural modulus ranged from 8.65 (SD 2.24) GPa (Vitablocs Mark II) to 16.10 (SD 5.94) GPa (IPS Empress CAD). IPS Empress CAD had the highest fracture toughness at 2.18 (SD 0.30) MPa.m(1/2), while Vitablocs Mark II had the lowest at 1.37 (SD 0.22) MPa.m(1/2). Paradigm C exhibited the highest thermal expansion coefficient at 16.87 (SD 4.37) 3 10(-6)/degrees C, and Vitablocs Mark II had the lowest at 8.60 (SD 1.47) 3 10(-6)/degrees C. The 3 ceramic materials significantly differed in all of the properties measured. Vitablocs Mark II was the hardest of the 3 materials, and IPS Empress CAD had the greatest flexure strength, flexural modulus, and fracture toughness.
- 25 December 2008
- Vol. 39 (7) , 573-9
Measurement of select physical and mechanical properties of 3 machinable ceramic materials.
To measure select physical and mechanical properties of 3 machinable ceramic materials (IPS Empress CAD, Ivoclar Vivadent; Vitablocs Mark II, Vident; Paradigm C, 3M ESPE). The physical and mechanical properties tested were hardness (using Vickers hardness), flexural strength and modulus (with 3-point bending), fracture toughness (with Vickers hardness indentation), and coefficient of thermal expansion (using a thermomechanical analyzer). For each of the materials, 25 specimens were fabricated to test each property, except for coefficient of thermal expansion, where n = 5. For each tested property, data were analyzed using 1-way analysis of variance and Tukey Studentized range test (significance level = .05), when required for post hoc testing. Mean Vickers hardness ranged from 511.3 (SD 8.6) for Paradigm C to 569.3 (SD 10.2) for Vitablocs Mark II. Flexural strength was greatest for IPS Empress CAD at 137.51 (SD 23.34) MPa and least for Vitablocs Mark II at 94.08 (SD 14.21) MPa. Flexural modulus ranged from 8.65 (SD 2.24) GPa (Vitablocs Mark II) to 16.10 (SD 5.94) GPa (IPS Empress CAD). IPS Empress CAD had the highest fracture toughness at 2.18 (SD 0.30) MPa.m(1/2), while Vitablocs Mark II had the lowest at 1.37 (SD 0.22) MPa.m(1/2). Paradigm C exhibited the highest thermal expansion coefficient at 16.87 (SD 4.37) 3 10(-6)/degrees C, and Vitablocs Mark II had the lowest at 8.60 (SD 1.47) 3 10(-6)/degrees C. The 3 ceramic materials significantly differed in all of the properties measured. Vitablocs Mark II was the hardest of the 3 materials, and IPS Empress CAD had the greatest flexure strength, flexural modulus, and fracture toughness.
- 1 July 2006
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 18 (4) , 214-222
Accuracy of LED and Halogen Radiometers Using Different Light Sources
Purpose: To determine the accuracy of commercially available, handheld light‐emitting diode (LED) and halogen‐based radiometers using LED and quartz‐tungsten‐halogen (QTH) curing lights with light guides of various diameters.Methods: The irradiance of an LED curing light (L.E.Demetron 1, SDS/Kerr, Orange, CA, USA) and a QTH curing light (Optilux 501, SDS/Kerr) were measured using multiple units of an LED (Demetron L.E.D. Radiometer, SDS/Kerr) and a halogen radiometer (Demetron 100, SDS/Kerr) and compared with each other and to a laboratory‐grade power meter (control). Measurements were made using five light guides with distal light guide diameters of 4, 7, 8, 10, and 12.5 mm. For each light guide, five readings were made with each of three radiometers of each radiometer type. Data were analyzed with two‐way analysis of variance/Tukey; α=0.05.Results: In general, both handheld radiometer types exhibited significantly different irradiance readings compared with the control meter. Additionally, readings between radiometer types were found to differ slightly, but were correlated. In general, the LED radiometer provided slightly lower irradiance readings than the halogen radiometer, irrespective of light source. With both types of handheld radiometers, the use of the larger‐diameter light guides tended to overestimate the irradiance values as seen in the control, while smaller‐diameter light guides tended to underestimate.CLINICAL SIGNIFICANCE: The evaluated LED or halogen handheld radiometers may be used interchangeably to determine the irradiance of both LED and QTH visible‐light‐curing units. Measured differences between the two radiometer types were small and probably not clinically significant. However, the diameter of light guides may affect the accuracy of the radiometers, with larger‐diameter light guides overestimating and smaller‐diameter guides underestimating the irradiance value measured by the control instrument.
- 1 July 2006
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 18 (4) , 214-222
Accuracy of LED and Halogen Radiometers Using Different Light Sources
Purpose: To determine the accuracy of commercially available, handheld light‐emitting diode (LED) and halogen‐based radiometers using LED and quartz‐tungsten‐halogen (QTH) curing lights with light guides of various diameters.Methods: The irradiance of an LED curing light (L.E.Demetron 1, SDS/Kerr, Orange, CA, USA) and a QTH curing light (Optilux 501, SDS/Kerr) were measured using multiple units of an LED (Demetron L.E.D. Radiometer, SDS/Kerr) and a halogen radiometer (Demetron 100, SDS/Kerr) and compared with each other and to a laboratory‐grade power meter (control). Measurements were made using five light guides with distal light guide diameters of 4, 7, 8, 10, and 12.5 mm. For each light guide, five readings were made with each of three radiometers of each radiometer type. Data were analyzed with two‐way analysis of variance/Tukey; α=0.05.Results: In general, both handheld radiometer types exhibited significantly different irradiance readings compared with the control meter. Additionally, readings between radiometer types were found to differ slightly, but were correlated. In general, the LED radiometer provided slightly lower irradiance readings than the halogen radiometer, irrespective of light source. With both types of handheld radiometers, the use of the larger‐diameter light guides tended to overestimate the irradiance values as seen in the control, while smaller‐diameter light guides tended to underestimate.CLINICAL SIGNIFICANCE: The evaluated LED or halogen handheld radiometers may be used interchangeably to determine the irradiance of both LED and QTH visible‐light‐curing units. Measured differences between the two radiometer types were small and probably not clinically significant. However, the diameter of light guides may affect the accuracy of the radiometers, with larger‐diameter light guides overestimating and smaller‐diameter guides underestimating the irradiance value measured by the control instrument.
- 1 September 2005
- Vol. 30 (4) , 528-32
Effect of handpiece maintenance method on bond strength.
This study evaluated the effect of dental handpiece lubricant on the shear bond strength of three bonding agents to dentin. A lubrication-free handpiece (one that does not require the user to lubricate it) and a handpiece requiring routine lubrication were used in the study. In addition, two different handpiece lubrication methods (automated versus manual application) were also investigated. One hundred and eighty extracted human teeth were ground to expose flat dentin surfaces that were then finished with wet silicon carbide paper. The teeth were randomly divided into 18 groups (n=10). The dentin surface of each specimen was exposed for 30 seconds to water spray from either a lubrication-free handpiece or a lubricated handpiece. Prior to exposure, various lubrication regimens were used on the handpieces that required lubrication. The dentin surfaces were then treated with total-etch, two-step; a self-etch, two-step or a self-etch, one-step bonding agent. Resin composite cylinders were bonded to dentin, the specimens were then thermocycled and tested to failure in shear at seven days. Mean bond strength data were analyzed using Dunnett's multiple comparison test at an 0.05 level of significance. Results indicated that within each of the bonding agents, there were no significant differences in bond strength between the control group and the treatment groups regardless of the type of handpiece or use of routine lubrication.
- 1 September 2005
- Vol. 30 (4) , 528-32
Effect of handpiece maintenance method on bond strength.
This study evaluated the effect of dental handpiece lubricant on the shear bond strength of three bonding agents to dentin. A lubrication-free handpiece (one that does not require the user to lubricate it) and a handpiece requiring routine lubrication were used in the study. In addition, two different handpiece lubrication methods (automated versus manual application) were also investigated. One hundred and eighty extracted human teeth were ground to expose flat dentin surfaces that were then finished with wet silicon carbide paper. The teeth were randomly divided into 18 groups (n=10). The dentin surface of each specimen was exposed for 30 seconds to water spray from either a lubrication-free handpiece or a lubricated handpiece. Prior to exposure, various lubrication regimens were used on the handpieces that required lubrication. The dentin surfaces were then treated with total-etch, two-step; a self-etch, two-step or a self-etch, one-step bonding agent. Resin composite cylinders were bonded to dentin, the specimens were then thermocycled and tested to failure in shear at seven days. Mean bond strength data were analyzed using Dunnett's multiple comparison test at an 0.05 level of significance. Results indicated that within each of the bonding agents, there were no significant differences in bond strength between the control group and the treatment groups regardless of the type of handpiece or use of routine lubrication.
- 1 July 2005
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 63 (7) , 957-960
Oral Surgical Handpiece Use Time Parameters
- 1 July 2005
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 63 (7) , 957-960
Oral Surgical Handpiece Use Time Parameters
- 1 July 2005
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 136 (7) , 915-919
Disinfectants' effect on mercury release from amalgam
- 1 July 2005
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 136 (7) , 915-919
Disinfectants' effect on mercury release from amalgam