How Does Robotic-Arm Assisted Technology Influence Total Knee Arthroplasty Implant Placement for Surgeons in Fellowship Training?
Authors:
- 9 September 2020
- journal article
- research article
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 35 (02) , 198-203
Abstract
Implant malalignment during total knee arthroplasty (TKA) may lead to suboptimal postoperative outcomes. Accuracy studies are typically performed with experienced surgeons; however, it is important to study less experienced surgeons when considering teaching hospitals where younger surgeons operate. Therefore, this study assessed whether robotic-arm assisted TKA (RATKA) allowed for more accurate and precise implant position to plan when compared with manual techniques when the surgery is performed by in-training orthopaedic surgical fellows. Two surgeons, currently in their fellowship training and having minimal RATKA experience, performed a total of six manual TKA (MTKA) and six RATKAs on paired cadaver knees. Computed tomography scans were obtained for each knee pre- and postoperatively. These scans were analyzed using a custom autosegmentation and autoregistration process to compare postoperative implant position with the preoperative planned position. Mean system errors and standard deviations were compared between RATKA and MTKA for the femoral component for sagittal, coronal, and axial planes and for the tibial component in the sagittal and coronal planes. A 2-Variance testing was performed using an α = 0.05. Although not statistically significant, RATKA was found to have greater accuracy and precision to plan than MTKA for: femoral axial plane (1.1° ± 1.1° vs. 1.6° ± 1.3°), coronal plane (0.9° ± 0.7° vs. 2.2° ± 1.0°), femoral sagittal plane (1.5° ± 1.3° vs. 3.1° ± 2.1°), tibial coronal plane (0.9° ± 0.5° vs. 1.9° ± 1.3°), and tibial sagittal plane (1.7° ± 2.6° vs. 4.7° ± 4.1°). There were no statistical differences between surgical groups or between the two surgeons performing the cases. With limited RATKA experience, fellows showed increased accuracy and precision to plan for femoral and tibial implant positions. Furthermore, these results were comparable to what has been reported for an experienced surgeon performing RATKA.Keywords
This publication has 17 references indexed in Scilit:
- Erratum to: The Learning Curve Associated with Robotic Total Knee ArthroplastyThe Journal of Knee Surgery, 2018
- Coronal Correction for Severe Deformity Using Robotic-Assisted Total Knee ArthroplastyThe Journal of Knee Surgery, 2017
- The Learning Curve Associated with Robotic Total Knee ArthroplastyThe Journal of Knee Surgery, 2017
- Patient Satisfaction Outcomes after Robotic Arm-Assisted Total Knee Arthroplasty: A Short-Term EvaluationThe Journal of Knee Surgery, 2017
- Current Failure Mechanisms After Knee Arthroplasty Have Changed: Polyethylene Wear Is Less Common in Revision SurgeryJournal of Bone and Joint Surgery, 2015
- Why knee replacements fail in 2013The Bone & Joint Journal, 2014
- Why Are Total Knee Arthroplasties Failing Today—Has Anything Changed After 10 Years?The Journal of Arthroplasty, 2014
- Mechanical, Anatomical, and Kinematic Axis in TKA: Concepts and Practical ApplicationsCurrent Reviews in Musculoskeletal Medicine, 2014
- Total knee arthroplasty in extra articular deformities: A series of 36 kneesIndian Journal of Orthopaedics, 2013
- Total knee arthroplasty in severe valgus deformity: Interest of combining a lateral approach with a tibial tubercle osteotomyOrthopaedics & Traumatology: Surgery & Research, 2010