Michael A. Mont
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Michael A. Mont has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
Nipun Sodhi
Department of Orthopaedic Surgery, Long Island Jewish Medical Center Northwell Health, New York, New York
28 shared publicationsJoseph O. Ehiorobo
Department of Orthopaedic Surgery Northwell Health, Lenox Hill Hospital New York, New York
14 shared publicationsHiba K. Anis
Department of Orthopedic Surgery, Cleveland Clinic, Cleveland, Ohio
12 shared publicationsAnton Khlopas
Cleveland Clinic
7 shared publicationsLuke J. Garbarino
Northwell Health Orthopaedics, Long Island Jewish Medical Center, New York, New York
7 shared publicationsPeter A. Gold
Northwell Health Orthopaedics, Long Island Jewish Medical Center, New York, New York
6 shared publications
Latest Publications
- 1 January 2022
- Published by Springer Nature
- p. 49-55
Osteonecrosis
- 10 September 2021
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 34 (13) , 1396-1401
The Epidemiology of Revision Total Knee Arthroplasty
With an expected increase in total knee arthroplasty (TKA) procedures, revision TKA (rTKA) procedures continue to be a burden on the United States health care system. The evolution of surgical techniques and prosthetic designs has, however, provided a paradigm shift in the etiology of failure mechanisms of TKA. This review can shed light on the current reasons for revision, which may lead to insights on how to improve outcomes and lower future revision risks. We will primarily focus on the epidemiology of rTKA in the present time, but we will also review this in the context of various time periods to see how the field has evolved. We will review rTKAs: 1) prior to 1997; 2) between 1997 and 2000; 3) between 2000 and 2012; and 3) in the modern era since 2012. We will further subdivide each of the sections into reasons for early (first 2 years after index procedure) versus late revisions (greater than 2 years after index procedure). In doing so, it was determined that prior to 1997, the most prevalent causes of failure were infection, patella failure, polyethylene wear, and aseptic loosening. After a major shift of failure mechanisms was described by Sharkey et al, polyethylene wear and aseptic loosening became the leading causes for revision. However, with the improved manufacturing technology and implant design, polyethylene wear was replaced with aseptic loosening and infection as the leading causes of failure between 2000 and 2012. Since that time, in the modern era of TKA, mechanical loosening and infection have taken over the most prevalent causes for failure. Hopefully, with continued developments in component design and surgical techniques, as well as increased focus on infection reduction methods, the amount of rTKA procedures will decline.
- 10 September 2021
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 34 (13) , 1396-1401
The Epidemiology of Revision Total Knee Arthroplasty
With an expected increase in total knee arthroplasty (TKA) procedures, revision TKA (rTKA) procedures continue to be a burden on the United States health care system. The evolution of surgical techniques and prosthetic designs has, however, provided a paradigm shift in the etiology of failure mechanisms of TKA. This review can shed light on the current reasons for revision, which may lead to insights on how to improve outcomes and lower future revision risks. We will primarily focus on the epidemiology of rTKA in the present time, but we will also review this in the context of various time periods to see how the field has evolved. We will review rTKAs: 1) prior to 1997; 2) between 1997 and 2000; 3) between 2000 and 2012; and 3) in the modern era since 2012. We will further subdivide each of the sections into reasons for early (first 2 years after index procedure) versus late revisions (greater than 2 years after index procedure). In doing so, it was determined that prior to 1997, the most prevalent causes of failure were infection, patella failure, polyethylene wear, and aseptic loosening. After a major shift of failure mechanisms was described by Sharkey et al, polyethylene wear and aseptic loosening became the leading causes for revision. However, with the improved manufacturing technology and implant design, polyethylene wear was replaced with aseptic loosening and infection as the leading causes of failure between 2000 and 2012. Since that time, in the modern era of TKA, mechanical loosening and infection have taken over the most prevalent causes for failure. Hopefully, with continued developments in component design and surgical techniques, as well as increased focus on infection reduction methods, the amount of rTKA procedures will decline.
- 9 September 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 35 (02) , 198-203
How Does Robotic-Arm Assisted Technology Influence Total Knee Arthroplasty Implant Placement for Surgeons in Fellowship Training?
Implant malalignment during total knee arthroplasty (TKA) may lead to suboptimal postoperative outcomes. Accuracy studies are typically performed with experienced surgeons; however, it is important to study less experienced surgeons when considering teaching hospitals where younger surgeons operate. Therefore, this study assessed whether robotic-arm assisted TKA (RATKA) allowed for more accurate and precise implant position to plan when compared with manual techniques when the surgery is performed by in-training orthopaedic surgical fellows. Two surgeons, currently in their fellowship training and having minimal RATKA experience, performed a total of six manual TKA (MTKA) and six RATKAs on paired cadaver knees. Computed tomography scans were obtained for each knee pre- and postoperatively. These scans were analyzed using a custom autosegmentation and autoregistration process to compare postoperative implant position with the preoperative planned position. Mean system errors and standard deviations were compared between RATKA and MTKA for the femoral component for sagittal, coronal, and axial planes and for the tibial component in the sagittal and coronal planes. A 2-Variance testing was performed using an α = 0.05. Although not statistically significant, RATKA was found to have greater accuracy and precision to plan than MTKA for: femoral axial plane (1.1° ± 1.1° vs. 1.6° ± 1.3°), coronal plane (0.9° ± 0.7° vs. 2.2° ± 1.0°), femoral sagittal plane (1.5° ± 1.3° vs. 3.1° ± 2.1°), tibial coronal plane (0.9° ± 0.5° vs. 1.9° ± 1.3°), and tibial sagittal plane (1.7° ± 2.6° vs. 4.7° ± 4.1°). There were no statistical differences between surgical groups or between the two surgeons performing the cases. With limited RATKA experience, fellows showed increased accuracy and precision to plan for femoral and tibial implant positions. Furthermore, these results were comparable to what has been reported for an experienced surgeon performing RATKA.
- 9 September 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 35 (02) , 198-203
How Does Robotic-Arm Assisted Technology Influence Total Knee Arthroplasty Implant Placement for Surgeons in Fellowship Training?
Implant malalignment during total knee arthroplasty (TKA) may lead to suboptimal postoperative outcomes. Accuracy studies are typically performed with experienced surgeons; however, it is important to study less experienced surgeons when considering teaching hospitals where younger surgeons operate. Therefore, this study assessed whether robotic-arm assisted TKA (RATKA) allowed for more accurate and precise implant position to plan when compared with manual techniques when the surgery is performed by in-training orthopaedic surgical fellows. Two surgeons, currently in their fellowship training and having minimal RATKA experience, performed a total of six manual TKA (MTKA) and six RATKAs on paired cadaver knees. Computed tomography scans were obtained for each knee pre- and postoperatively. These scans were analyzed using a custom autosegmentation and autoregistration process to compare postoperative implant position with the preoperative planned position. Mean system errors and standard deviations were compared between RATKA and MTKA for the femoral component for sagittal, coronal, and axial planes and for the tibial component in the sagittal and coronal planes. A 2-Variance testing was performed using an α = 0.05. Although not statistically significant, RATKA was found to have greater accuracy and precision to plan than MTKA for: femoral axial plane (1.1° ± 1.1° vs. 1.6° ± 1.3°), coronal plane (0.9° ± 0.7° vs. 2.2° ± 1.0°), femoral sagittal plane (1.5° ± 1.3° vs. 3.1° ± 2.1°), tibial coronal plane (0.9° ± 0.5° vs. 1.9° ± 1.3°), and tibial sagittal plane (1.7° ± 2.6° vs. 4.7° ± 4.1°). There were no statistical differences between surgical groups or between the two surgeons performing the cases. With limited RATKA experience, fellows showed increased accuracy and precision to plan for femoral and tibial implant positions. Furthermore, these results were comparable to what has been reported for an experienced surgeon performing RATKA.
- 1 September 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 33 (09) , 847
Cementless Total Knee Arthroplasty
Component fixation, by way of cemented or cementless techniques, for total knee arthroplasty (TKA) has been a matter of debate for a very long time. Currently, cemented TKA is the industry standard due, in part, to earlier literature that identified potential concerns with cementless fixation. However, more recently, substantial new evidence in the literature has revealed the possible advantages of avoiding cement. Specifically, studies have addressed cost savings, due to decrease material use and shorter operative times from not having to wait for cement to dry, equivalent patient-reported outcomes and survivorship, and versatility of use in higher-risk populations. The studies reported in this Special Section help provide more answers to the cement versus cementless debate. Here, we present three unique reports on a minimum 5-year survivorship and outcomes of cementless TKA, and focus on porous metal-backed patellar component outcomes, an often overlooked analysis. Additionally, we provide the readers a comprehensive literature review of cementless fixation in various patient populations such as younger and older patients, as well as those afflicted with rheumatoid arthritis and osteonecrosis of the knee. This Special Section addresses one of the longest debated topics concerning TKA. The data and insights presented in this section would not only help inform patients and providers but also guide surgical techniques. We therefore anticipate the readership to benefit who would find these articles to be of great interest and reference. Publication Date: 01 September 2020 (online) © 2020. Thieme. All rights reserved. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
- 1 September 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 33 (09) , 847
Cementless Total Knee Arthroplasty
Component fixation, by way of cemented or cementless techniques, for total knee arthroplasty (TKA) has been a matter of debate for a very long time. Currently, cemented TKA is the industry standard due, in part, to earlier literature that identified potential concerns with cementless fixation. However, more recently, substantial new evidence in the literature has revealed the possible advantages of avoiding cement. Specifically, studies have addressed cost savings, due to decrease material use and shorter operative times from not having to wait for cement to dry, equivalent patient-reported outcomes and survivorship, and versatility of use in higher-risk populations. The studies reported in this Special Section help provide more answers to the cement versus cementless debate. Here, we present three unique reports on a minimum 5-year survivorship and outcomes of cementless TKA, and focus on porous metal-backed patellar component outcomes, an often overlooked analysis. Additionally, we provide the readers a comprehensive literature review of cementless fixation in various patient populations such as younger and older patients, as well as those afflicted with rheumatoid arthritis and osteonecrosis of the knee. This Special Section addresses one of the longest debated topics concerning TKA. The data and insights presented in this section would not only help inform patients and providers but also guide surgical techniques. We therefore anticipate the readership to benefit who would find these articles to be of great interest and reference. Publication Date: 01 September 2020 (online) © 2020. Thieme. All rights reserved. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
- 31 August 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 35 (03) , 337-344
Improved Component Placement Accuracy with Robotic-Arm Assisted Total Knee Arthroplasty
Component position of total knee arthroplasty (TKA) has been shown to influence prosthetic survivorships and clinical outcomes. Our objective was to compare the three-dimensional accuracy to plan of robotic-arm assisted TKA (RATKA) with conventional TKA for component position. We conducted a nonrandomized, prospective study comparing 143 RATKA with 86 conventional TKA operated at four U.S. centers between July 2016 and October 2018. Computed tomography (CT) scans obtained approximately 6 weeks postoperatively were analyzed using anatomical landmarks. Absolute deviation from surgical plans were defined as the absolute value of the difference between the CT measurements and surgeons' femoral and tibial component mechanical varus/valgus alignment, tibial component posterior slope, and femoral component internal/external rotation. Differences of absolute deviations were tested using stratified Wilcoxon's tests that controlled for study center. Patient-reported outcome measures collected through 1 postoperative year were modeled using multiple regression controlling for age, sex, body mass index, study center, and the preoperative score. RATKA demonstrated greater accuracy for tibial component alignment (median [25th, 75th percentiles] absolute deviation from plan of all centers combined for conventional vs. RA, 1.7 [0.9, 2.9] vs. 0.9 [0.4, 1.9] degrees, p < 0.001), femoral component rotation (1.5 [0.9, 2.5] vs. 1.3 [0.6, 2.5] degrees, p = 0.015), and tibial slope (2.9 [1.5, 5.0] vs. 1.1 [0.6, 2.0] degrees, p < 0.001). In multivariable analyses, RATKA showed significantly greater Veterans RAND 12-item health survey (VR-12) physical component scores (adjusted mean difference [95% confidence interval (CI)]: 2.4 [0.2, 4.5] points, p = 0.034) and qualitatively greater Knee Society (KS) composite functional scores (3.5 [−1.3, 8.2] points, p = 0.159), though not statistically significant. Compared with conventional instrumentation, RATKA demonstrated greater three-dimensional accuracy to plan for various component positioning parameters and clinical improvements in physical status and function with no major safety concerns during the first postoperative year. These results may be attributed to the preoperative CT scan planning, real-time intraoperative feedback, and stereotactic-guided cutting that takes into consideration patient-specific bony anatomy. These findings support the use of RATKA for enhanced arthroplasty outcomes.
- 31 August 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 35 (03) , 337-344
Improved Component Placement Accuracy with Robotic-Arm Assisted Total Knee Arthroplasty
Component position of total knee arthroplasty (TKA) has been shown to influence prosthetic survivorships and clinical outcomes. Our objective was to compare the three-dimensional accuracy to plan of robotic-arm assisted TKA (RATKA) with conventional TKA for component position. We conducted a nonrandomized, prospective study comparing 143 RATKA with 86 conventional TKA operated at four U.S. centers between July 2016 and October 2018. Computed tomography (CT) scans obtained approximately 6 weeks postoperatively were analyzed using anatomical landmarks. Absolute deviation from surgical plans were defined as the absolute value of the difference between the CT measurements and surgeons' femoral and tibial component mechanical varus/valgus alignment, tibial component posterior slope, and femoral component internal/external rotation. Differences of absolute deviations were tested using stratified Wilcoxon's tests that controlled for study center. Patient-reported outcome measures collected through 1 postoperative year were modeled using multiple regression controlling for age, sex, body mass index, study center, and the preoperative score. RATKA demonstrated greater accuracy for tibial component alignment (median [25th, 75th percentiles] absolute deviation from plan of all centers combined for conventional vs. RA, 1.7 [0.9, 2.9] vs. 0.9 [0.4, 1.9] degrees, p < 0.001), femoral component rotation (1.5 [0.9, 2.5] vs. 1.3 [0.6, 2.5] degrees, p = 0.015), and tibial slope (2.9 [1.5, 5.0] vs. 1.1 [0.6, 2.0] degrees, p < 0.001). In multivariable analyses, RATKA showed significantly greater Veterans RAND 12-item health survey (VR-12) physical component scores (adjusted mean difference [95% confidence interval (CI)]: 2.4 [0.2, 4.5] points, p = 0.034) and qualitatively greater Knee Society (KS) composite functional scores (3.5 [−1.3, 8.2] points, p = 0.159), though not statistically significant. Compared with conventional instrumentation, RATKA demonstrated greater three-dimensional accuracy to plan for various component positioning parameters and clinical improvements in physical status and function with no major safety concerns during the first postoperative year. These results may be attributed to the preoperative CT scan planning, real-time intraoperative feedback, and stereotactic-guided cutting that takes into consideration patient-specific bony anatomy. These findings support the use of RATKA for enhanced arthroplasty outcomes.
- 30 June 2020
- Published by Georg Thieme Verlag KG in The Journal of Hip Surgery
- Vol. 04 (02) , 090-093
Minimum 7-Year Outcomes of Dual Mobility Acetabular Cups in Total Hip Arthroplasty Patients
Modular dual mobility cups have been developed to potentially address postoperative hip instability, which can occur in nearly 20% of all revision total hip arthroplasty (THA) patients. By having a prosthetic construct that contains two points of articulation between the femoral head and liner and between the liner and shell, joint stability can be increased. The purpose of this study was to report on dual mobility cup survivorships, patient satisfaction outcomes, complications, and radiographic outcomes at a minimum 7-year follow-up. A high-volume academic surgeon performed a total of 143 consecutive dual mobility primary THAs on patients who had a minimum follow-up of 7 years (range, 7–8.5 years). The study cohort consisted of 77 females (54%) and 66 males (46%) who had a mean age of 65 years (range, 34–90 years). Aseptic, septic, and all-cause survivorship was determined by Kaplan-Meier analysis. Harris Hip Scores (HHS), postoperative complications, and radiographs were also assessed. No cup failures were observed. Overall, septic survivorship was 99.3% (95% confidence interval [CI]: 0.98–1.0) and all-cause survivorship was 98.6% (95% CI: 0.97–1.0). Two patients (1.4%) required revision surgery unrelated to the use of a modular dual mobility cup. Of these, one patient experienced femoral stem loosening and the other developed a periprosthetic infection that was treated with a two-stage revision. The mean total HHS was above 95 points at the most recent follow-up. Three patients (2.3%) experienced medical complications, including two deep vein thromboses and one for nonfatal pulmonary embolism. Radiographic evidence revealed incomplete seating of the metallic liner in one patient. Dual mobility cups were developed in an attempt to decrease the rate of instability following THA. The results from this study indicate that excellent clinical and patient-reported outcomes can be achieved at 7-year follow-up in patients who undergo THA with a dual mobility cup. Therefore, dual mobility cups appear to be an appropriate treatment option for primary THA.
- 30 June 2020
- Published by Georg Thieme Verlag KG in The Journal of Hip Surgery
- Vol. 04 (02) , 090-093
Minimum 7-Year Outcomes of Dual Mobility Acetabular Cups in Total Hip Arthroplasty Patients
Modular dual mobility cups have been developed to potentially address postoperative hip instability, which can occur in nearly 20% of all revision total hip arthroplasty (THA) patients. By having a prosthetic construct that contains two points of articulation between the femoral head and liner and between the liner and shell, joint stability can be increased. The purpose of this study was to report on dual mobility cup survivorships, patient satisfaction outcomes, complications, and radiographic outcomes at a minimum 7-year follow-up. A high-volume academic surgeon performed a total of 143 consecutive dual mobility primary THAs on patients who had a minimum follow-up of 7 years (range, 7–8.5 years). The study cohort consisted of 77 females (54%) and 66 males (46%) who had a mean age of 65 years (range, 34–90 years). Aseptic, septic, and all-cause survivorship was determined by Kaplan-Meier analysis. Harris Hip Scores (HHS), postoperative complications, and radiographs were also assessed. No cup failures were observed. Overall, septic survivorship was 99.3% (95% confidence interval [CI]: 0.98–1.0) and all-cause survivorship was 98.6% (95% CI: 0.97–1.0). Two patients (1.4%) required revision surgery unrelated to the use of a modular dual mobility cup. Of these, one patient experienced femoral stem loosening and the other developed a periprosthetic infection that was treated with a two-stage revision. The mean total HHS was above 95 points at the most recent follow-up. Three patients (2.3%) experienced medical complications, including two deep vein thromboses and one for nonfatal pulmonary embolism. Radiographic evidence revealed incomplete seating of the metallic liner in one patient. Dual mobility cups were developed in an attempt to decrease the rate of instability following THA. The results from this study indicate that excellent clinical and patient-reported outcomes can be achieved at 7-year follow-up in patients who undergo THA with a dual mobility cup. Therefore, dual mobility cups appear to be an appropriate treatment option for primary THA.
- 19 June 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 33 (09) , 862-865
Cementless Tritanium Baseplate Total Knee Arthroplasty: Survivorship and Outcomes at 5-Year Minimum Follow-Up
Background Newer generation cementless total knee arthroplasty (TKA) designs have provided stronger osteointegration between the implant and bone. Despite excellent survivorship and outcomes with cemented TKAs, areas of concern within the bone–cement interface remain a concern and necessitate studies on alternative constructs. This study assesses: (1) implant survivorship; (2) clinical outcomes; and (3) complications with radiographic outcomes at a 5-year minimum follow-up of cementless highly porous titanium-coated baseplates in TKAs. Methods Part of this study has been reported. We retrospectively reviewed a prospectively collected database at a single high-volume institution between July 1, 2013 and June 30, 2014 for patients who underwent a primary TKA using cementless highly porous titanium-coated baseplate implants. Patients were evaluated clinically at postoperative follow-up visits at a minimum of 5 years. To calculate the survivorship, Kaplan–Meier analysis was performed to determine all-cause, aseptic, and septic implant survivorship at each final follow-up for all patients. Results A total of 228 TKAs were performed and followed for a minimum of 5 years (range, 5–6 years). As of the latest follow-up, one case of septic loosening of the patellar button and one case of patellar dislodgment secondary to physical manipulation were recorded and revised. Overall, the cohort displayed implant survivorship of 99.5% at 5-year minimum follow-up. Improvements were seen in both Knee Society pain and function scores and were 37 points (range, 17–60 points) and 28 points (range, 15–47 points), respectively. The mean improvement in flexion was 17.8 (range, –20 to 40 degrees) and mean improvement in extension was –5.5 (range, –30 to 5 degrees). Discussion Cementless TKAs serve as strong alternative choice to cemented TKAs. Although cemented fixation is commonly known as the gold standard, results of this study confirm the findings of previous investigations on the survivorship of cementless TKA implants. Therefore, patients who undergo primary TKA with a cementless tritanium baseplate can expect excellent clinical outcomes at a 5-year minimum follow-up.
- 19 June 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 33 (09) , 862-865
Cementless Tritanium Baseplate Total Knee Arthroplasty: Survivorship and Outcomes at 5-Year Minimum Follow-Up
Background Newer generation cementless total knee arthroplasty (TKA) designs have provided stronger osteointegration between the implant and bone. Despite excellent survivorship and outcomes with cemented TKAs, areas of concern within the bone–cement interface remain a concern and necessitate studies on alternative constructs. This study assesses: (1) implant survivorship; (2) clinical outcomes; and (3) complications with radiographic outcomes at a 5-year minimum follow-up of cementless highly porous titanium-coated baseplates in TKAs. Methods Part of this study has been reported. We retrospectively reviewed a prospectively collected database at a single high-volume institution between July 1, 2013 and June 30, 2014 for patients who underwent a primary TKA using cementless highly porous titanium-coated baseplate implants. Patients were evaluated clinically at postoperative follow-up visits at a minimum of 5 years. To calculate the survivorship, Kaplan–Meier analysis was performed to determine all-cause, aseptic, and septic implant survivorship at each final follow-up for all patients. Results A total of 228 TKAs were performed and followed for a minimum of 5 years (range, 5–6 years). As of the latest follow-up, one case of septic loosening of the patellar button and one case of patellar dislodgment secondary to physical manipulation were recorded and revised. Overall, the cohort displayed implant survivorship of 99.5% at 5-year minimum follow-up. Improvements were seen in both Knee Society pain and function scores and were 37 points (range, 17–60 points) and 28 points (range, 15–47 points), respectively. The mean improvement in flexion was 17.8 (range, –20 to 40 degrees) and mean improvement in extension was –5.5 (range, –30 to 5 degrees). Discussion Cementless TKAs serve as strong alternative choice to cemented TKAs. Although cemented fixation is commonly known as the gold standard, results of this study confirm the findings of previous investigations on the survivorship of cementless TKA implants. Therefore, patients who undergo primary TKA with a cementless tritanium baseplate can expect excellent clinical outcomes at a 5-year minimum follow-up.
- 29 May 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 33 (09) , 856-861
Outcomes of Cementless-Backed Patellar Components
Because of the early follow-up positive outcomes with cementless fixation, continued evaluations need to be performed to ensure longer-term efficacy. Additionally, although many studies report on the results of femoral and tibial component fixation, few studies report specifically on patellar outcomes. Therefore, the purpose of this study was to report on the: (1) implant survivorship; (2) complications; and (3) radiographic outcomes in a large cohort of patients who received cementless total knee arthroplasties (TKAs), with particular attention to the patellar component. A total of 261 patients who underwent cementless TKA by a single, high-volume academic surgeon were studied. Patients had a mean age of 66 years and were distributed between 192 women (74%) and 69 men. All patients received the same cementless tibial, femoral, and patellar components. Mean follow-up period was 4.5 years (range, 4–5 years). Primary outcomes evaluated included all postoperative complications, with particular emphasis on the patellar component. Only one patellar loosened leading to a patellar aseptic loosening rate of 0.3% (1 of 261). The one patellar loosening was the component being dislodged after a manipulation under anesthesia (MUA) at 6 weeks. This was revised to a cemented component and the patient is doing well 4 years later. A second patient experienced a patellar tendon rupture, later surgically repaired. Another patient sustained a patella fracture that was managed nonoperatively. The fracture healed by 1 year and the patient continued to have an otherwise successful outcome, now at 2 years follow-up. No progressive radiolucencies, subsidence, or changes in initial postoperative axial alignment were observed at final follow-up. The results from this study highlight a 98% success rate at mean 4.5 years follow-up in a large cohort of patients with a diverse spread of demographic details. Specific to the patella, only one patient experienced an adverse event, which was managed nonoperatively. Therefore, based on this data, patellar fixation in cementless TKA can be considered a safe technique.
- 29 May 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 33 (09) , 856-861
Outcomes of Cementless-Backed Patellar Components
Because of the early follow-up positive outcomes with cementless fixation, continued evaluations need to be performed to ensure longer-term efficacy. Additionally, although many studies report on the results of femoral and tibial component fixation, few studies report specifically on patellar outcomes. Therefore, the purpose of this study was to report on the: (1) implant survivorship; (2) complications; and (3) radiographic outcomes in a large cohort of patients who received cementless total knee arthroplasties (TKAs), with particular attention to the patellar component. A total of 261 patients who underwent cementless TKA by a single, high-volume academic surgeon were studied. Patients had a mean age of 66 years and were distributed between 192 women (74%) and 69 men. All patients received the same cementless tibial, femoral, and patellar components. Mean follow-up period was 4.5 years (range, 4–5 years). Primary outcomes evaluated included all postoperative complications, with particular emphasis on the patellar component. Only one patellar loosened leading to a patellar aseptic loosening rate of 0.3% (1 of 261). The one patellar loosening was the component being dislodged after a manipulation under anesthesia (MUA) at 6 weeks. This was revised to a cemented component and the patient is doing well 4 years later. A second patient experienced a patellar tendon rupture, later surgically repaired. Another patient sustained a patella fracture that was managed nonoperatively. The fracture healed by 1 year and the patient continued to have an otherwise successful outcome, now at 2 years follow-up. No progressive radiolucencies, subsidence, or changes in initial postoperative axial alignment were observed at final follow-up. The results from this study highlight a 98% success rate at mean 4.5 years follow-up in a large cohort of patients with a diverse spread of demographic details. Specific to the patella, only one patient experienced an adverse event, which was managed nonoperatively. Therefore, based on this data, patellar fixation in cementless TKA can be considered a safe technique.
- 8 April 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 34 (12) , 1318-1321
Does Increasing Patient Complexity Have an Effect on Medical Outcomes and Lengths-of-Stay after Total Knee Arthroplasty?
A greater number of medically complex patients with multiple comorbidities are now more readily considered for total knee arthroplasty (TKA). Therefore, the purpose of this study was to determine whether comorbidity burden, measured with the Elixhauser Comorbidity Index (ECI), correlated with 90-day medical complications and longer in-hospital lengths-of-stay (LOS) in TKA patients. The PearlDiver supercomputer was queried for all primary TKA patients in the Medicare Standard Analytic Files from 2005 to 2014 using International Classification of Disease, 9th edition codes. Patients were included based on ECI scores, ranging from 1 to 5. ECI 1 patients served as the control cohort, while ECI 2, 3, 4, and 5 patients were considered study cohorts. Each study cohort was matched based on age and gender to the control cohort, resulting in a total of 715,398 patients included for analysis (ECI 1, n = 144,072; ECI 2, n = 144,072; ECI 3, n = 144,072; ECI 4, n = 144,072; ECI 5, n = 139,110). Logistic regression analyses were performed to compare 90-day medical complications and Welch's t-tests were performed to compare LOS between the cohorts. Patients with higher ECI scores were more likely to develop medical complications and have longer LOS compared with matched patients in the control cohort. Compared with matched ECI 1 patients, patients with ECI scores of 2 (odds ratio [OR]: 1.19, 95% confidence interval [CI]: 1.14–1.24), 3 (OR: 1.27, 95% CI: 1.21–1.32), 4 (OR: 1.32, 95% CI: 1.27–1.38), and 5 (OR: 1.33, 95% CI: 1.27–1.39) were significantly more likely to develop 90-day medical complications. Additionally, the mean LOS of patients in the ECI 2 (2.59 ± 1.49 vs. 2.73 ± 1.52 days), ECI 3 (2.59 ± 1.49 vs. 2.88 ± 1.51 days; p < 0.001), ECI 4 (2.59 ± 1.49 vs. 3.01 ± 1.56 days; p < 0.001), and ECI 5 (2.61 ± 1.49 vs. 3.14 ± 1.61 days; p < 0.001) groups were significantly longer than the mean LOS in the control ECI 1 group. In an increasingly complex patient population, associations between comorbidities and outcomes after TKA procedures can guide providers on how to modify their pre- and postoperative care. These results demonstrate that higher ECI scores are associated with a greater likelihood of 90-day medical complications and longer in-hospital LOS.
- 8 April 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 34 (12) , 1318-1321
Does Increasing Patient Complexity Have an Effect on Medical Outcomes and Lengths-of-Stay after Total Knee Arthroplasty?
A greater number of medically complex patients with multiple comorbidities are now more readily considered for total knee arthroplasty (TKA). Therefore, the purpose of this study was to determine whether comorbidity burden, measured with the Elixhauser Comorbidity Index (ECI), correlated with 90-day medical complications and longer in-hospital lengths-of-stay (LOS) in TKA patients. The PearlDiver supercomputer was queried for all primary TKA patients in the Medicare Standard Analytic Files from 2005 to 2014 using International Classification of Disease, 9th edition codes. Patients were included based on ECI scores, ranging from 1 to 5. ECI 1 patients served as the control cohort, while ECI 2, 3, 4, and 5 patients were considered study cohorts. Each study cohort was matched based on age and gender to the control cohort, resulting in a total of 715,398 patients included for analysis (ECI 1, n = 144,072; ECI 2, n = 144,072; ECI 3, n = 144,072; ECI 4, n = 144,072; ECI 5, n = 139,110). Logistic regression analyses were performed to compare 90-day medical complications and Welch's t-tests were performed to compare LOS between the cohorts. Patients with higher ECI scores were more likely to develop medical complications and have longer LOS compared with matched patients in the control cohort. Compared with matched ECI 1 patients, patients with ECI scores of 2 (odds ratio [OR]: 1.19, 95% confidence interval [CI]: 1.14–1.24), 3 (OR: 1.27, 95% CI: 1.21–1.32), 4 (OR: 1.32, 95% CI: 1.27–1.38), and 5 (OR: 1.33, 95% CI: 1.27–1.39) were significantly more likely to develop 90-day medical complications. Additionally, the mean LOS of patients in the ECI 2 (2.59 ± 1.49 vs. 2.73 ± 1.52 days), ECI 3 (2.59 ± 1.49 vs. 2.88 ± 1.51 days; p < 0.001), ECI 4 (2.59 ± 1.49 vs. 3.01 ± 1.56 days; p < 0.001), and ECI 5 (2.61 ± 1.49 vs. 3.14 ± 1.61 days; p < 0.001) groups were significantly longer than the mean LOS in the control ECI 1 group. In an increasingly complex patient population, associations between comorbidities and outcomes after TKA procedures can guide providers on how to modify their pre- and postoperative care. These results demonstrate that higher ECI scores are associated with a greater likelihood of 90-day medical complications and longer in-hospital LOS.
- 8 April 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 34 (12) , 1296-1303
Benefits of CT Scanning for the Management of Knee Arthritis and Arthroplasty
This review investigated the potential value of computed tomography (CT) scans for the evaluation and management of knee arthritis and arthroplasty. Specifically, we evaluated the following: (1) assessment of arthritis within knee compartments, (2) patellofemoral joint assessment, (3) implant sizing prediction, (4) component alignment, (5) soft-tissue protection, and (6) potential concerns with radiation exposure. To compare if CT or X-ray imaging is more accurate and clinically relevant, a search was performed using Boolean search operators and terms: “CT,” “radiograph,” “joint alignment,” “knee,” and “arthroplasty,” which yielded 661 results. Studies were evaluated based on (1) assessment of arthritis within knee compartments, (2) patellofemoral joint assessment, (3) implant sizing prediction, (4) component alignment, (5) soft-tissue protection, and (6) potential concerns with radiation exposure. Correlative and comparative analyses of imaging modalities to pre-, intra-, and postoperative clinical and patient-related factors were performed for the 63 included studies. CT scans were found to better detect medial and lateral arthritic changes, bony deformities, subchondral cysts, and cartilage losses. CT scans were shown to 99% accurately predict prosthetic sizes preoperatively. CT scans can also help better visualize surrounding anatomy, such as the posterior cruciate ligament, and have therefore been linked to better soft tissue protection during total knee arthroplasty. Although radiation is a potential concern, newer imaging protocols have comparable exposure to plain radiographs. Compared with plain radiographs, CT scans were found to be more accurate and provide more clinically relevant data. Therefore, the authors recommend the use of CT for the evaluation of certain patients with arthritis and for preoperative planning for knee arthroplasty.
- 8 April 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 34 (12) , 1296-1303
Benefits of CT Scanning for the Management of Knee Arthritis and Arthroplasty
This review investigated the potential value of computed tomography (CT) scans for the evaluation and management of knee arthritis and arthroplasty. Specifically, we evaluated the following: (1) assessment of arthritis within knee compartments, (2) patellofemoral joint assessment, (3) implant sizing prediction, (4) component alignment, (5) soft-tissue protection, and (6) potential concerns with radiation exposure. To compare if CT or X-ray imaging is more accurate and clinically relevant, a search was performed using Boolean search operators and terms: “CT,” “radiograph,” “joint alignment,” “knee,” and “arthroplasty,” which yielded 661 results. Studies were evaluated based on (1) assessment of arthritis within knee compartments, (2) patellofemoral joint assessment, (3) implant sizing prediction, (4) component alignment, (5) soft-tissue protection, and (6) potential concerns with radiation exposure. Correlative and comparative analyses of imaging modalities to pre-, intra-, and postoperative clinical and patient-related factors were performed for the 63 included studies. CT scans were found to better detect medial and lateral arthritic changes, bony deformities, subchondral cysts, and cartilage losses. CT scans were shown to 99% accurately predict prosthetic sizes preoperatively. CT scans can also help better visualize surrounding anatomy, such as the posterior cruciate ligament, and have therefore been linked to better soft tissue protection during total knee arthroplasty. Although radiation is a potential concern, newer imaging protocols have comparable exposure to plain radiographs. Compared with plain radiographs, CT scans were found to be more accurate and provide more clinically relevant data. Therefore, the authors recommend the use of CT for the evaluation of certain patients with arthritis and for preoperative planning for knee arthroplasty.