XAFS measurement system using undulator synchronized on-the-fly monochromator scan at SPring-8 BL36XU
Authors:
- Nozomu IshiguroNINozomu Ishiguro
- Tomoya UrugaTUTomoya Uruga
- Takuma KanekoTKTakuma Kaneko
- Takashi TanakaTTTakashi Tanaka
- Yasumasa JotiYJYasumasa Joti
- Koji MotomuraKMKoji Motomura
- Hiroshi YamazakiHYHiroshi Yamazaki
- Yasunori SenbaYSYasunori Senba
- Haruhiko OhashiHOHaruhiko Ohashi
- Makina YabashiMYMakina Yabashi
- Yukio TakahashiYTYukio Takahashi
Open Access
- 26 August 2026
- journal article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (5) , 1478-1485
Abstract
In X-ray absorption fine structure (XAFS) measurements at undulator beamlines, it has been difficult to simultaneously achieve both spectral time resolution and high X-ray flux that fully utilizes the optical performance of the beamline. To overcome this challenge, we developed a synchronization architecture for undulator beamlines, in which the undulator gap serves as the master axis while a compact channel-cut monochromator follows a pre-calculated nonlinear trajectory. In contrast to conventional feedback approaches, in which the monochromator serves as the master, the undulator gap is used as the master axis, enabling fast and flexible nonlinear synchronization with the compact channel-cut monochromator. Transmission and fluorescence quick-XAFS (QXAFS) measurements were successfully performed at the Ni K edge in the extended X-ray absorption fine structure (EXAFS) region within 6.4 s. The incident photon flux was six times higher than that of conventional QXAFS using a tapered and fixed undulator gap at the same acquisition time, demonstrating that the proposed synchronization architecture enables high-flux EXAFS measurements that were previously difficult to achieve with undulator-based QXAFS.Keywords
Funding Information
- Japan Society for the Promotion of Science (JP22KJ0302)
- Japan Society for the Promotion of Science (JP26K01202)
This publication has 26 references indexed in Scilit:
- High precision real-time insertion device and monochromator synchronization at NSLS-IINuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022
- Variation of Local Structure and Reactivity of Pt/C Catalyst for Accelerated Degradation Test of Polymer Electrolyte Fuel Cell Visualized by Operando 3D CT‐XAFS ImagingChemnanomat, 2022
- SPring‐8 BL36XU: Synchrotron Radiation X‐Ray‐Based Multi‐Analytical Beamline for Polymer Electrolyte Fuel Cells under Operating ConditionsThe Chemical Record, 2019
- Operando Time-Resolved X-ray Absorption Fine Structure Study for Pt Oxidation Kinetics on Pt/C and Pt3Co/C Cathode Catalysts by Polymer Electrolyte Fuel Cell Voltage Operation Synchronized with Rapid O2 ExposureThe Journal of Physical Chemistry C, 2018
- Kinetics and Mechanism of Redox Processes of Pt/C and Pt3Co/C Cathode Electrocatalysts in a Polymer Electrolyte Fuel Cell during an Accelerated Durability TestThe Journal of Physical Chemistry C, 2016
- QEXAFS: Techniques and Scientific Applications for Time‐Resolved XAS2016
- Rate Enhancements in Structural Transformations of Pt–Co and Pt–Ni Bimetallic Cathode Catalysts in Polymer Electrolyte Fuel Cells Studied by in Situ Time-Resolved X-ray Absorption Fine StructureThe Journal of Physical Chemistry C, 2014
- Hard X-rays QEXAFS instrumentation with scan range 20 to 4000eVNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- Novel angular encoder for a quick-extended x-ray absorption fine structure monochromatorReview of Scientific Instruments, 2008
- A New XAFS Beamline NW10A at the Photon FactoryAIP Conference Proceedings, 2007