Due to the emergence of COVID-19 becoming a significant pandemic worldwide, hospitals are expected to be capable and flexible in responding to the pandemic situation. Moreover, as frontline healthcare staff, emergency department (ED) staff have a high possibility of exposure risk to infectious airborne. The ED isolation room will possibly and effectively isolate the infected patient, therefore safekeeping frontline healthcare staff and controlling the outbreak. However, there is still limited knowledge available regarding isolation room facilities specifically for the emergency department. In this study, field measurement is conducted in an ED isolation room located in Taiwan. CFD simulation is employed to simulate and investigate the airflow and airborne contaminant distribution. Instead of high air-change rates (ACH) that purposes for dilution, this study proposes the arrangement of exhaust air grilles to improve the contaminant removal. The results reveal that the exhaust air grille placed behind the patient’s head is optimized to dilute airborne contaminants.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (MOST 109-2622-E-167-002-CC3)
This publication has 22 references indexed in Scilit:
- CO2 tracer gas concentration decay method for measuring air change rateBuilding and Environment, 2015
- Infection Prevention in the Emergency DepartmentAnnals of Emergency Medicine, 2014
- Effect of Mesh Parameters in Finite Element Simulation of Single Point Incremental Sheet Forming ProcessProcedia Materials Science, 2014
- Australasian College for Emergency Medicine, Emergency Medicine Australasia and social mediaEmergency Medicine Australasia, 2012
- A CFD-based test method for control of indoor environment and space ventilationBuilding and Environment, 2010
- Numerical study on the dispersion of airborne contaminants from an isolation room in the case of door openingApplied Thermal Engineering, 2009
- An experimental study on ventilation efficiency of isolation roomBuilding and Environment, 2009
- Dynamic airflow simulation within an isolation roomBuilding and Environment, 2007
- Development of ventilation design strategy for effective removal of pollutant in the isolation room of a hospitalBuilding and Environment, 2006
- Virus diffusion in isolation roomsJournal of Hospital Infection, 2006